JJS-EMFUTUR J-E001 Horizontal Laminar Flow Clean Bench with Integrated High-Purity Water Purification System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand JJS-EMFUTUR (Nanomaterials Division)
Origin Spain
Manufacturer Type Authorized Distributor
Import Status Imported
Model J-E001
Price Range USD 2,700–6,800
Instrument Category Horizontal Laminar Flow Clean Bench
Cleanliness Class ISO Class 5 (≤100 particles ≥0.5 µm per ft³)
Noise Level <58 dB(A)
User Capacity 1–50 personnel
Airflow Pattern Unidirectional Horizontal Laminar Flow
Pure Water Output (25°C) 24 L/h
Power Consumption 240 W
Flow Rate (with pressurized storage tank) >1.5 L/min
Resistivity (25°C) 18.2 MΩ·cm
Total Organic Carbon (TOC) ≤3 ppb
Endotoxin <0.001 EU/mL
Bacterial Count <1 CFU/mL
Particles (>0.1 µm) <1 particle/mL
Heavy Metal Ions <0.1 ppb
Feed Water Conductivity Two-Stage RO Pre-Treated
Inlet Water Requirements 5–45°C, Pressure 1.0–4.0 kgf/cm²
Dimensions (L×W×H) 545×470×610 mm
Weight ~20 kg
Voltage AC 110–220 V, 50/60 Hz

Overview

The JJS-EMFUTUR J-E001 is a dual-function laboratory workstation engineered for environments demanding simultaneous particulate-free air handling and ultra-high-purity water delivery. Unlike conventional clean benches or standalone water purification systems, this integrated unit combines ISO Class 5 horizontal laminar flow containment with a multi-stage purification train—including two-stage reverse osmosis, electrodeionization (EDI), and ultrafiltration—to deliver Type I ultrapure water compliant with ASTM D1193-20 and ISO 3696:1987 Grade 1 specifications. Its unidirectional horizontal airflow minimizes turbulence-induced contamination across the work surface, while the embedded water system eliminates external tubing, reducing biofilm risk and enabling direct dispensing at point-of-use. Designed for analytical laboratories performing trace-level elemental, organic, and biological assays, the J-E001 supports workflows where airborne particulates and ionic/organic contaminants must be concurrently controlled—such as HPLC mobile phase preparation, ICP-MS standard dilution, TOC vial rinsing, and capillary electrophoresis buffer conditioning.

Key Features

  • Integrated horizontal laminar flow clean bench with HEPA-filtered (≥99.999% @ 0.3 µm) airflow, validated to ISO 14644-1 Class 5 under operational conditions
  • Dual-stage RO + EDI + 0.1 µm ultrafiltration + UV (185/254 nm) purification train ensuring consistent 18.2 MΩ·cm resistivity and ≤3 ppb TOC
  • Real-time resistivity and TOC monitoring with digital display; automatic system diagnostics and alarm logging
  • Compact footprint (545 × 470 × 610 mm) optimized for benchtop integration in regulated labs without dedicated utility rooms
  • Low-noise operation (<58 dB(A)) achieved via brushless DC fan control and acoustic dampening in the air plenum
  • Pressure-stabilized delivery circuit enabling >1.5 L/min flow at point-of-use without pulsation or backpressure sensitivity
  • Non-leaching polypropylene and PTFE-wetted components throughout the fluid path to prevent metallic ion leaching or organic extractables

Sample Compatibility & Compliance

The J-E001 meets critical material compatibility requirements for high-sensitivity analytical applications. Its purified water output satisfies USP specifications for Water for Injection (WFI)-adjacent quality—particularly endotoxin (<0.001 EU/mL) and microbial limits (<1 CFU/mL)—making it suitable for cell culture media preparation and ELISA reagent formulation. The horizontal airflow configuration ensures minimal cross-contamination during open-vessel handling of volatile organics or low-boiling solvents. All wetted materials comply with FDA 21 CFR §177.1520 (polypropylene) and §177.1550 (PTFE). The system supports GLP/GMP documentation through optional audit-trail-enabled software (see Software & Data Management). It is certified to IEC 61000-6-3 (EMC) and IEC 61010-1 (safety), with CE marking for use in EU-based research and QC laboratories.

Software & Data Management

The J-E001 includes an embedded microcontroller with RS-232 and USB interfaces for connection to laboratory information management systems (LIMS). Optional firmware upgrade enables 21 CFR Part 11-compliant electronic records: user-authenticated access, time-stamped event logs (e.g., filter replacement, resistivity deviation, UV lamp runtime), and immutable data export in CSV or PDF format. Calibration history, maintenance alerts, and real-time water quality metrics are stored locally for ≥12 months. No cloud dependency is required—data remains on-premise unless explicitly configured for secure network transmission via TLS 1.2.

Applications

  • HPLC and UHPLC mobile phase and standard solution preparation requiring low TOC and metal-free water
  • ICP-MS sample introduction, calibration standard dilution, and nebulizer rinsing where sub-ppt background interference is unacceptable
  • TOC analyzer validation and blank verification per EPA Method 415.3 and ISO 8466-2
  • Capillary electrophoresis buffer formulation and electrode rinsing to prevent current instability
  • Toxicology research involving low-concentration metabolite quantification by LC-MS/MS
  • Environmental analysis of trace heavy metals (e.g., Pb, Cd, As) in soil leachates and wastewater effluents
  • Preparation of CRISPR-Cas9 transfection reagents and primary neuronal culture media

FAQ

What is the recommended maintenance schedule for the J-E001’s purification modules?

Pre-filters require replacement every 3–6 months depending on feed water quality; RO membranes every 24 months; EDI cartridge and UF membrane every 12 months. A built-in timer and pressure differential sensors trigger visual and audible alerts.

Can the J-E001 be connected to a central purified water loop?

No—it is designed exclusively for point-of-use operation. Integration with centralized systems would compromise its validated purity profile and invalidate ISO Class 5 airflow certification.

Is the horizontal airflow compatible with flammable solvent use?

Yes. The unit lacks ignition sources and features non-sparking motors. However, local fire codes and institutional EH&S policies must be consulted prior to use with Class I solvents.

Does the system support remote monitoring via Ethernet or Wi-Fi?

Ethernet connectivity is available via optional module (J-E001-NET); Wi-Fi is not supported due to electromagnetic interference risks in sensitive analytical zones.

How is calibration traceability established for resistivity and TOC measurements?

Resistivity sensor is factory-calibrated against NIST-traceable KCl standards; TOC module uses sucrose calibration per USP . Certificates of conformance accompany each unit.