Empowering Scientific Discovery

Boxun BSD-TX318 Benchtop Orbital Shaker

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Boxun
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model BSD-TX318
Price Range USD 1,400–2,800
Instrument Type Full-Temperature Orbital Shaker
Timer Range 0–999 h
Oscillation Frequency 30–250 rpm (up to 600 rpm at amplitude <5 mm)
Oscillation Amplitude Φ0–40 mm, continuously adjustable
Temperature Range RT+6°C to 60°C
Temperature Control Accuracy ±0.1°C
Temperature Uniformity ±1°C (at 37°C)
Number of Shelving Plates 1
Chamber Volume 18 L
Plate Dimensions 290 × 260 mm
Power Consumption 400 W
Input Voltage AC 220 V, 50/60 Hz
Drive System Single-axis DC brushless motor
Control Algorithm PID microprocessor-based environmental scanning controller
Display Backlit LCD screen
Safety Features Over-temperature audiovisual alarm, power-failure recovery, parameter lockout, acceleration ramp control

Overview

The Boxun BSD-TX318 Benchtop Orbital Shaker is an integrated full-temperature orbital shaker engineered for precision-controlled cultivation, suspension culture, and biochemical mixing applications in academic research laboratories, biopharmaceutical QC/QA environments, and clinical diagnostics settings. It operates on the principle of orbital motion—generating uniform circular agitation to maximize oxygen transfer and homogeneity in liquid cultures without shear-induced cell damage. Unlike reciprocating or vortex shakers, its single-axis drive architecture ensures stable, low-vibration operation across the entire frequency and amplitude spectrum. The unit integrates a thermostatically regulated chamber with real-time PID feedback control, enabling simultaneous temperature and agitation management—critical for aerobic microbial growth, enzyme kinetics assays, and protein solubilization protocols where thermal stability directly influences reaction reproducibility.

Key Features

  • Single-axis DC brushless motor drive: Delivers consistent torque and speed stability across the full 30–250 rpm range (extendable to 600 rpm at low-amplitude settings), with zero carbon brush wear, no maintenance requirement, and immunity to line voltage fluctuations.
  • Continuously adjustable orbital amplitude (Φ0–40 mm): Enables precise tuning of mixing intensity to match oxygen demand profiles—e.g., low amplitude (≤10 mm) for sensitive mammalian cell suspensions; high amplitude (≥30 mm) for viscous media or high-density bacterial cultures.
  • PID-based microprocessor controller with environmental scanning logic: Monitors ambient drift and dynamically adjusts heating output to maintain setpoint accuracy within ±0.1°C and spatial uniformity of ±1°C (measured at 37°C per ISO 13485-aligned validation practices).
  • Backlit LCD interface: Displays real-time values for temperature, speed, amplitude, remaining time, and system status—supporting dual-parameter concurrent monitoring without menu navigation.
  • Comprehensive safety architecture: Includes over-temperature cut-off with independent thermal fuse, audible/visual alarm activation upon deviation >2°C from setpoint, parameter encryption lock to prevent unauthorized modification, and programmable ramp-up acceleration to protect fragile samples during start-up.
  • Power-failure recovery function: Automatically resumes pre-interruption operating conditions—including timer countdown, temperature setpoint, and oscillation parameters—after grid restoration, ensuring protocol continuity in unattended overnight runs.

Sample Compatibility & Compliance

The BSD-TX318 accommodates standard laboratory vessels including Erlenmeyer flasks (250 mL × 5 standard loading), test tubes (50 mL × 9, 100 mL × 9, or 250 mL × 6 maximum load), and multi-well plates when mounted on optional adapters. Its 18 L chamber volume and 290 × 260 mm platform support scalable workflows while maintaining mechanical stability under full load. The instrument conforms to IEC 61010-1:2010 safety standards for laboratory electrical equipment and meets electromagnetic compatibility requirements per EN 61326-1. While not certified for GMP manufacturing environments, its parameter logging capability, audit-trail-ready operation history, and locked configuration mode support GLP-compliant documentation per OECD Principles of Good Laboratory Practice (Section 5.2.3). Temperature calibration traceability aligns with NIST-traceable reference standards.

Software & Data Management

The BSD-TX318 operates as a standalone instrument with embedded firmware—no external PC or proprietary software required. All operational data (start time, duration, temperature profile, speed/amplitude logs) are stored in non-volatile memory and accessible via the LCD interface. For integration into centralized lab informatics systems, RS-232 serial output (optional accessory) enables ASCII-formatted data export compatible with LIMS platforms supporting ASTM E1384 or HL7 v2.x message structures. Parameter lockout and session-based access control meet FDA 21 CFR Part 11 foundational requirements for electronic records integrity, though full electronic signature functionality requires third-party middleware deployment.

Applications

  • Aerobic microbial cultivation (E. coli, yeast, Bacillus spp.) under controlled O₂-transfer conditions
  • Mammalian and insect cell suspension expansion in serum-free or low-serum media
  • Enzyme activity assays requiring thermal stabilization during kinetic measurements
  • Solubilization and reconstitution of lyophilized proteins and antibodies
  • Agarose gel casting support for electrophoresis sample preparation
  • Environmental microbiology studies involving soil slurry or wastewater enrichment

FAQ

What is the maximum flask size supported on the standard platform?
The 290 × 260 mm platform accommodates up to five 250 mL Erlenmeyer flasks using standard clamps. Larger vessels require custom mounting fixtures.
Does the unit support remote monitoring or network connectivity?
No built-in Ethernet or Wi-Fi interface is provided; RS-232 serial output is available as an optional hardware module for basic telemetry integration.
Is calibration documentation included with shipment?
A factory calibration certificate (traceable to national standards) is supplied, covering temperature accuracy at 37°C and speed verification at 150 rpm. On-site recalibration services are available through authorized Boxun service partners.
Can the shaker operate without temperature control enabled?
Yes—the heating element can be disabled while retaining full oscillation control, allowing ambient-temperature shaking for applications requiring only mechanical mixing.
What maintenance intervals are recommended for long-term reliability?
The brushless motor requires no scheduled maintenance. Annual verification of temperature sensor drift and periodic cleaning of air intake grilles are advised per ISO/IEC 17025 Clause 5.5.4 preventive maintenance guidelines.