Empowering Scientific Discovery

Mitutoyo WLI-Unit Series White Light Interferometric Microscope with WLI Plan Apo Objectives

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Mitutoyo
Model WLI-Unit-003 / WLI-Unit-005 / WLI-Unit-010
Sensor Head Cable Length 5 m
Compatible Objectives WLI Plan Apo Series
Imaging Magnification
Focal Length (f) 100 mm
Scanner Dimensions / Mass 108 × 68 × 191 mm / 1.7 kg
Z-Axis Measurement Range 8000 µm
WLI Measurement Z-Range (High-Throughput Mode) 2100 µm / 1900 µm / 1700 µm
Acquisition Time @ 20 µm Range 3 s / 4 s / 6 s
Z-Axis Resolution ≤ 4 nm
Z-Axis Repeatability ≤ 40 nm
Software WLIPAK
Calibration Tools Pixel Calibration SW, MCubeMap Analysis Module
Image Acquisition Matrox Frame Grabber (included)
SDK WLI-Unit Control Library with Example Code and GUI Templates

Overview

The Mitutoyo WLI-Unit Series is a precision white light interferometric (WLI) microscope system engineered for non-contact, high-resolution 3D surface topography and micro-roughness characterization. Based on the principle of low-coherence interferometry, the system generates interference fringes by splitting broadband white light between a reference arm and a measurement arm—where the sample surface acts as the reflective element. Unlike laser-based interferometers, WLI eliminates coherence noise and enables robust phase retrieval across surfaces with heterogeneous reflectivity, including mixed metallic-dielectric or polished-etched regions. The WLI-Unit integrates seamlessly with Mitutoyo’s proprietary WLI Plan Apo objectives—designed specifically to preserve fringe contrast over wide reflectivity ranges (0.1%–100%) without manual gain adjustment. This architecture ensures quantitative height data acquisition under consistent illumination conditions, even when high- and low-reflectance features coexist within a single field of view—a critical capability for semiconductor metrology, MEMS inspection, and precision mold validation.

Key Features

  • Non-contact 3D surface profiling with sub-nanometer Z-axis resolution (≤ 4 nm) and ≤ 40 nm repeatability across full measurement range
  • Simultaneous high-fidelity measurement of surfaces with disparate reflectivity—no dynamic exposure compensation required
  • Z-scanning via integrated objective-mounted piezo actuator with 8000 µm total travel and programmable scan modes (high-throughput, standard, high-resolution)
  • WLI Plan Apo objectives featuring long working distance (60 mm parfocal distance), high numerical aperture (NA), flat-field correction, and apochromatic design for minimal chromatic aberration
  • Integrated beam splitter and reference mirror housed within each objective—eliminating external alignment sensitivity and enhancing vibration immunity
  • Compact sensor head (108 × 68 × 191 mm; 1.7 kg) compatible with standard optical tables, coordinate measuring machines (CMMs), and automated inspection platforms

Sample Compatibility & Compliance

The WLI-Unit supports measurement of optically reflective and semi-reflective samples—including silicon wafers, sapphire substrates, hardened steel tooling, optical coatings, and polymer-molded microstructures. Its insensitivity to surface reflectivity gradients meets ASTM E2922–22 requirements for 3D surface texture analysis in manufacturing quality control. System calibration traceability aligns with ISO/IEC 17025-accredited procedures using NIST-traceable step-height standards. The hardware and WLIPAK software support audit-ready data logging compliant with FDA 21 CFR Part 11 when configured with electronic signatures and secure user access controls. All mechanical and optical components adhere to RoHS 2011/65/EU directives and CE marking requirements for laboratory instrumentation.

Software & Data Management

WLIPAK is a dedicated, Windows-based application providing real-time fringe analysis, surface reconstruction, and ISO 25178-compliant roughness parameter extraction (Sa, Sq, Sz, Sdr, etc.). The software includes pixel-level calibration routines, tilt correction algorithms, and automatic defect segmentation tools. For integration into automated production lines or custom metrology workflows, the WLI-Unit SDK delivers a C/C++ and Python-compatible control library with documented APIs, thread-safe command queues, and GUI-ready example code—including a fully functional Qt-based reference interface. Optional MCubeMap analysis module extends capabilities to curvature mapping, slope distribution histograms, and layer-thickness estimation on transparent films. Raw interferogram data (16-bit TIFF stacks) and processed height maps are stored in vendor-neutral formats supporting third-party post-processing in MATLAB, Python (OpenCV, scikit-image), or Metrology Suite environments.

Applications

  • Semiconductor process control: trench depth, contact hole profile, CMP uniformity, and lithographic resist topography
  • Precision machining validation: surface finish of injection molds, turbine blades, and medical implant surfaces
  • MEMS and micro-optics: actuator displacement, mirror flatness, grating pitch verification, and lenslet array form error
  • Advanced materials R&D: graphene layer thickness mapping, thin-film stress-induced buckling, and corrosion pit morphology quantification
  • Calibration laboratory use: certification of step-height artifacts, roughness standards, and stylus profiler reference samples

FAQ

What is the maximum measurable surface slope angle with the WLI Plan Apo 1× objective?
The system maintains reliable fringe contrast up to ±15° local surface inclination under standard illumination—beyond which optional tilting stages or multi-angle stitching protocols are recommended.
Can the WLI-Unit be synchronized with external motion controllers or trigger signals?
Yes—via TTL-compatible trigger I/O ports and Ethernet-based command interface, enabling precise coordination with motorized XY stages, environmental chambers, or inline production sensors.
Is GLP/GMP-compliant data archiving supported out-of-the-box?
WLIPAK supports configurable audit trails, electronic signatures, and encrypted database logging; full 21 CFR Part 11 compliance requires deployment on validated IT infrastructure and documented SOPs.
Does the system require periodic recalibration of the Z-axis encoder?
No—the piezo-driven Z-scanner uses closed-loop capacitance feedback; only annual verification against traceable step-height standards is recommended per ISO 10360-5.
Are there compatibility constraints with third-party image acquisition hardware?
While Matrox frame grabbers are supplied and fully tested, the SDK exposes low-level camera control registers—enabling integration with select PCIe Gen3 vision cards meeting GenICam v3.1 specifications.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0