Empowering Scientific Discovery

HePu MWD-800 Sealed Intelligent Microwave Digestion System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
[Brand HePu (Jihepu)
Origin Shandong, China
Model MWD-800
Sample Capacity 1–20 vessels (upgradable to 40/70 high-throughput rotors)
Microwave Source Single magnetron
Max Temperature 250 °C
Max Operating Pressure 6 MPa
Cavity Volume 65 L
Power Output 0–3000 W (variable-frequency continuous mode)
Pressure Control Multi-fiber non-contact scanning pressure monitoring
Temperature Control Mid-infrared non-contact scanning temperature monitoring
Vessel Material TFM-lined inner vessels
Safety Certification Dual-pressure/temperature interlock, auto-resealing rupture disc, 360° continuous rotation, <5 mW/cm² microwave leakage]

Overview

The HePu MWD-800 Sealed Intelligent Microwave Digestion System is a fully integrated, laboratory-grade sample preparation platform engineered for rapid, reproducible, and trace-metal-preserving acid digestion of solid and semi-solid matrices. Utilizing controlled microwave energy at 2450 MHz, the system delivers uniform volumetric heating via dielectric loss mechanisms—eliminating thermal gradients inherent in conductive heating methods such as hot plates or block digesters. Its sealed-vessel architecture enables elevated temperature–pressure conditions (up to 250 °C and 6 MPa), accelerating decomposition kinetics while minimizing volatile element loss (e.g., As, Hg, Se, Cd) and reducing reagent consumption by >70% compared to open-vessel techniques. Designed for compliance with ISO 17025-accredited laboratories, the MWD-800 supports method development aligned with EPA Method 3051A, 3052, ASTM D5511, and USP <231> heavy metal testing protocols.

Key Features

  • Auto-resealing dual-pressure relief system: Patented self-recovering rupture disc design allows transient overpressure events (≤10 MPa) to vent safely—and then reseal automatically—preserving batch integrity and eliminating cross-contamination risk between vessels.
  • Chemically inert vessel construction: Inner vessels machined from ultra-pure TFM (modified PTFE) with ≤0.1 ng/g blank levels for trace metals; outer containment shells formed from reinforced PEEK + fiberglass composites rated to 20 MPa burst pressure and stable in aqua regia, HF, and organic solvent mixtures.
  • 65 L industrial cavity with modular rotor compatibility: Accommodates 20-position high-pressure rotors (100 mL vessels), 40- or 70-position high-throughput configurations, and optional rotor adapters for legacy vessel formats—enabling seamless scalability across routine QC and research workflows.
  • Independent per-vessel monitoring: Mid-infrared optical sensors measure real-time solution temperature inside each vessel; multi-fiber optic pressure transducers provide non-contact, drift-free pressure readings—all without physical penetration into the reaction environment.
  • 360° continuous rotation platform: Eliminates standing-wave hot spots through unidirectional orbital motion, ensuring uniform field distribution across all vessel positions and reducing mechanical stress on drive components versus oscillating systems.
  • 8-inch external color touchscreen controller: Displays synchronized real-time graphs of temperature, pressure, power, and time; includes dedicated per-vessel parameter windows, audit-trail-enabled method editing, and GLP-compliant event logging (including door opening, pressure spikes, and power fluctuations).

Sample Compatibility & Compliance

The MWD-800 processes diverse sample types—including soils, sediments, biological tissues, polymers, catalysts, pharmaceutical excipients, foodstuffs, and battery cathode materials—using HNO₃, HCl, HF, H₂O₂, and mixed acid chemistries. Its pressure-rated TFM/PEEK vessel system meets ISO 15195 requirements for certified reference material (CRM) digestion and is validated for use in laboratories operating under FDA 21 CFR Part 11 (with optional electronic signature module), EU GMP Annex 11, and CNAS-CL01:2018 frameworks. All safety interlocks—including door-open shutdown, temperature/pressure runaway cutoff, motor fault detection, and acoustic anomaly monitoring—are hardware-locked and independently verified per IEC 61000-4-3 EMC standards.

Software & Data Management

Embedded firmware supports storage of up to 255 user-defined methods, each containing 10 sequential steps with independent setpoints for temperature (50–400 °C), pressure (0–10 MPa), ramp time, hold time, and microwave power (0–3000 W). Real-time parameter adjustment is permitted during active runs—critical for method optimization and troubleshooting. Data export is supported via USB 2.0 and RS-232 serial interface; optional Ethernet connectivity enables remote monitoring and integration with LIMS platforms. All method executions generate timestamped, tamper-evident logs compliant with ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available).

Applications

  • Environmental analysis: Total recoverable metals in EPA SW-846 Method 3052 digests for ICP-MS/OES quantification
  • Food safety: Lead, cadmium, and arsenic determination in infant formula per ISO 6497 and GB 5009.12
  • Pharmaceutical QA: Residual catalyst screening in API intermediates per ICH Q2(R2)
  • Geochemical mapping: Rare earth element (REE) extraction from silicate rocks using HF-based protocols
  • Battery R&D: Cobalt, nickel, and lithium recovery from NMC cathodes prior to hydrometallurgical recycling
  • Clinical toxicology: Mercury speciation in hair and blood samples following closed-vessel HNO₃/H₂O₂ digestion

FAQ

What safety certifications does the MWD-800 comply with?
The system conforms to IEC 61010-1 (Electrical Safety), IEC 61000-4-3 (EMC Immunity), and GB 4793.6 (Chinese National Standard for Microwave Equipment). Optional third-party validation reports are available for ISO/IEC 17025 and FDA 21 CFR Part 11 readiness.
Can the MWD-800 be integrated into an automated sample prep line?
Yes—via digital I/O ports and Modbus RTU protocol support, it interfaces with robotic autosamplers and pneumatic vessel loaders for unattended 24/7 operation.
Is HF digestion supported?
Yes. The TFM/PEEK vessel configuration is fully compatible with hydrofluoric acid up to 40% concentration at temperatures ≤220 °C and pressures ≤5 MPa—validated per ASTM D7348 Annex A2.
How is calibration traceability maintained?
Mid-infrared temperature sensors are factory-calibrated against NIST-traceable blackbody sources; pressure transducers are calibrated using dead-weight testers with ±0.01 MPa accuracy—certificates provided with each instrument shipment.
What maintenance intervals are recommended?
Annual verification of cavity integrity, magnetron output stability, and sensor linearity is advised. No routine consumables beyond replacement gaskets (supplied in maintenance kits) are required under normal operating conditions.