Empowering Scientific Discovery

HengaoDe HAD-H370 Intrinsically Safe Capacitive Humidity & Dew Point Analyzer | Digital Vane Anemometer HAD-HT625B | HAD-100C Horizontal Laboratory Roll Press | FERROMASTER Portable Digital Permeameter (μ = 1.001–1.999) | HAD-W200A Automatic Surface & Interfacial Tensiometer | HAD-KM-5A Particle Abrasion Tester | HAD-CRACK-8 Smart Crack Width Gauge | LPG Sampling Cylinder (316L, 5 L, 4 MPa) | SH0387 Wire Rope Surface Grease Slippage Tester | Dry-Type Transformer Cross-Flow Cooling Fan (JB/T 8971–1999 Compliant)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HengaoDe
Origin Beijing, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model HAD-H370 (Humidity/Dew Point), HAD-HT625B (Anemometer), HAD-100C (Roll Press), FERROMASTER (Permeameter), HAD-W200A (Tensiometer), HAD-KM-5A (Abrasion Tester), HAD-CRACK-8 (Crack Gauge), LPG Cylinder (316L, 5000 mL, 4 MPa), SH0387 Grease Slippage Tester, Transformer Fan (JB/T 8971–1999)
Price USD 42.50 (excl. tax & shipping)

Overview

This integrated instrumentation suite comprises nine distinct, application-specific analytical and physical testing devices engineered for laboratory, quality control, and industrial R&D environments. The HAD-H370 is a certified intrinsically safe capacitive humidity and dew point analyzer designed for hazardous area deployment (Exd IIC T6), measuring relative humidity (0–100% RH), volumetric absolute humidity (0–40% vol), and dew point temperature (−20 to +100 °C) with ≤±1.5% FS accuracy. The HAD-HT625B digital vane anemometer delivers simultaneous wind velocity (0.40–30.00 m/s), ambient temperature (−20.0 to +60.0 °C), and dew point (−50.0 to +60.0 °C) readings via a calibrated axial impeller sensor. The HAD-100C horizontal roll press enables controlled cold rolling of battery electrode coatings and metallic foils using dual hardened 9Cr2Mo steel rollers (Φ100 mm, HRC62, cylindrical tolerance ±0.002 mm) with adjustable gap (0–3 mm) and variable line speed (0–6.0 m/min). The FERROMASTER portable permeameter quantifies low magnetic permeability (μ = 1.001–1.999) in austenitic stainless steels, NMR components, and non-ferrous alloys using dual-field Hall-effect sensing referenced to UK National Physical Laboratory (NPL) traceable standards. The HAD-W200A automatic tensiometer implements the Du Noüy ring method per ASTM D971, ISO 6295, GB/T 6541, and QB/T 1323, delivering surface/interfacial tension measurements (0–200.0 mN/m) with ≤±1% FS repeatability. The HAD-KM-5A particle abrasion tester complies with HG/T 2158–2004 and GB/T 36365–2018 for catalyst and adsorbent attrition evaluation under programmable rotational conditions (25–60 rpm, 0–99 min). The HAD-CRACK-8 smart crack width gauge performs non-contact optical measurement of structural concrete and metal surface cracks (0.01–8.00 mm) with automated edge detection, USB data export, and BMP/JPEG image capture. The 316L stainless steel LPG sampling cylinder (5000 mL, 4 MPa W.P.) conforms to ISO 4745 and ASTM D1265 for representative liquefied petroleum gas sampling. The SH0387 wire rope grease slippage tester executes standardized thermal migration assessment per SH 0387 at temperatures up to 200 °C (±0.5 °C control). Finally, the cross-flow cooling fan meets JB/T 8971–1999 for dry-type transformer derating applications, featuring aluminum die-cast impellers, low-noise ball bearings, and silicon steel laminations.

Key Features

  • HAD-H370: IP65-rated enclosure; 316L stainless steel probe (0.5–1.2 m standard); 4–20 mA analog output with programmable relay alarm; 24 V DC operation; 24-month sensor service life under normal sampling conditions.
  • HAD-HT625B: LCD display with 9999-count resolution; 0.5 s sampling interval; wind chill and wet-bulb temperature calculation; auto-hold function; IP65-rated housing.
  • HAD-100C: Single-phase 220 V input; manual pressure adjustment via precision handwheel; chrome-plated roller surfaces; optional heating module for thermomechanical rolling studies.
  • FERROMASTER: 3½-digit LCD with hold function; built-in NPL-traceable calibration standard; operates independent of Earth’s geomagnetic field; 100-hour battery life on 9 V alkaline cell.
  • HAD-W200A: High-precision 24-bit AD converter (Analog Devices); optimized torsion-wire lever geometry for linear force response; LVDT displacement transducer; auto-stop lift stage with configurable dwell time.
  • HAD-KM-5A: Dual 120 mm ID abrasion drums with internal baffle; microprocessor-controlled stepper motor; programmable rotation speed and duration; integrated 40-mesh (850 µm) vibratory sieve (1–9 Hz).
  • HAD-CRACK-8: 40×/20×/13×/10× interchangeable optical probes; real-time pixel-based width computation; embedded lithium-ion battery; U-disk image storage; GJG 125–99 compliance reporting.
  • LPG Cylinder: Seamless 316L construction; hydrostatic test pressure ≥6 MPa; stamped serial number and certification mark per ASME BPVC Section VIII.
  • SH0387 Tester: PID temperature controller; 1.05 kW heating element; illuminated sample chamber; digital setpoint display.
  • Transformer Fan: Axial cross-flow design; airflow rating per JB/T 8971–1999; mounting flange options for top-blow or side-blow configurations.

Sample Compatibility & Compliance

All instruments are validated for use with materials commonly encountered in energy storage, petrochemical, metallurgical, civil infrastructure, and pharmaceutical manufacturing sectors. The HAD-H370 complies with IEC 60079-0/-1/-11 for explosive atmospheres and meets CE marking requirements for electromagnetic compatibility (EMC Directive 2014/30/EU). The HAD-W200A supports GLP-compliant data integrity through timestamped result logging and operator ID fields (when integrated with optional PC software). The FERROMASTER adheres to ISO/IEC 17025 metrological traceability protocols via its NPL-certified calibration reference. The HAD-KM-5A satisfies Chinese national standards for catalyst attrition (HG/T 2158) and aligns with ASTM D5756 for solid particulate erosion testing. The HAD-CRACK-8 generates audit-ready reports conforming to GB 50292–2015 (Code for Safety Assessment of Existing Buildings) and EN 1504-4 for structural condition monitoring. None of the listed instruments require FDA 21 CFR Part 11 validation, though raw data files (BMP, CSV, TXT) are natively exportable without proprietary encryption.

Software & Data Management

The HAD-W200A and HAD-CRACK-8 support direct USB mass-storage mode for plug-and-play file transfer—no drivers required. Tensiometer results are stored as CSV with date/time stamps, test number, and operator code; crack gauge images retain EXIF metadata including magnification factor and measurement coordinates. Optional Windows-based analysis suites (sold separately) provide statistical process control (SPC) charts, trend analysis, and PDF report generation compliant with ISO 9001:2015 clause 8.5.2. All firmware updates are delivered via signed ZIP packages with SHA-256 checksum verification. Calibration logs for FERROMASTER and HAD-H370 include certificate numbers, reference standard IDs, and environmental conditions at time of verification—retained locally on device memory for ≥100 cycles.

Applications

  • HAD-H370: Continuous moisture monitoring in natural gas dehydration units, compressed air systems, and semiconductor cleanroom purge lines.
  • HAD-HT625B: HVAC commissioning, fume hood face velocity verification, and wind tunnel calibration checks.
  • HAD-100C: Electrode density optimization for Li-ion battery prototyping; foil thickness uniformity studies for flexible electronics substrates.
  • FERROMASTER: Incoming inspection of 316L/304 stainless fasteners; magnetic contamination screening in medical implant packaging; permeability mapping of thin-film magnetic shields.
  • HAD-W200A: Surfactant critical micelle concentration (CMC) determination; polymer solution interfacial stability assessment; emulsion formulation QC per USP .
  • HAD-KM-5A: Catalyst lifetime prediction for FCC units; mechanical robustness screening of MOF-based CO₂ sorbents.
  • HAD-CRACK-8: Bridge deck distress surveys per AASHTO LRFD; post-earthquake structural triage; long-term corrosion propagation tracking.
  • LPG Cylinder: Field sampling for sulfur compound speciation (ASTM D6667) and vapor pressure analysis (ASTM D1267).
  • SH0387 Tester: Quality release testing of galvanized wire rope lubricants per ISO 12214.
  • Transformer Fan: Thermal management validation for ANSI/IEEE C57.12.00 dry-type transformers operating at >80% load factor.

FAQ

Is the HAD-H370 certified for Zone 1 hazardous locations?
Yes—the entire assembly carries Exd IIC T6 certification per IEC 60079-1, permitting installation in gas Group IIC environments with maximum surface temperature ≤85 °C.
Can the FERROMASTER measure permeability below μ = 1.001?
No—its lower detection limit is fixed at μ = 1.001. For diamagnetic materials (e.g., copper, water), alternative techniques such as SQUID magnetometry are required.
Does the HAD-W200A support platinum-iridium rings per ISO 14070?
Yes—ring accessories conforming to ISO 14070:2021 Annex A are available as optional add-ons; standard configuration uses ASTM E1138-compliant stainless steel rings.
What is the maximum particle size acceptable for the HAD-KM-5A abrasion test?
Particles must pass through a 4.75 mm sieve prior to loading; oversized fragments may damage drum baffles or induce non-uniform wear patterns.
Are calibration certificates supplied with each instrument?
Factory calibration certificates (including uncertainty budgets) are included for HAD-H370, FERROMASTER, and HAD-W200A. Traceable recalibration services are offered annually with NIST-traceable reference standards.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0