HengaoDe H02983 Manual Thin-Layer Chromatography (TLC) Spotter
| Brand | HengaoDe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | H02983 |
| Price | USD 92 (FOB) |
| Spot Uniformity | < 0.2 mm |
| Plate Size Capacity | 200 × 200 mm |
| Spotting Method | Capillary or Microsyringe |
| Multi-Channel Capability | Yes |
Overview
The HengaoDe H02983 Manual Thin-Layer Chromatography (TLC) Spotter is a precision laboratory instrument engineered for reproducible, low-variability sample application onto planar chromatographic plates. Designed specifically for pharmaceutical quality control (QC), natural product analysis, and academic research laboratories, this manual spotter operates on mechanical displacement principles—leveraging calibrated micrometer-driven stage movement and fixed-height spotting nozzles—to ensure consistent sample deposition volume and spatial accuracy across multiple lanes. Unlike automated spotters requiring complex calibration or software integration, the H02983 delivers GLP-compliant spot placement without dependency on external computing systems, making it ideal for regulated environments where audit trails and operational simplicity are prioritized. Its robust aluminum alloy frame and corrosion-resistant surface finish support long-term use in solvent-rich fume hood environments typical of preparative TLC workflows.
Key Features
- High-precision mechanical positioning system with sub-millimeter repeatability (< 0.2 mm spot-to-spot uniformity)
- Adjustable stage accommodating standard 200 × 200 mm TLC plates, including pre-coated silica gel, alumina, and cellulose layers
- Multi-channel spotting capability enabling parallel application of up to 8 samples per run (configurable via interchangeable nozzle arrays)
- Capillary and microsyringe compatibility—supports both gravity-fed capillary spotting and positive-displacement syringe-based delivery
- Ergonomic handwheel control with tactile feedback for fine vertical positioning of spotting tips relative to plate surface
- Non-magnetic stainless steel spotting tips resistant to organic solvents (e.g., chloroform, ethyl acetate, methanol)
- No electrical components or firmware—eliminates electromagnetic interference risks and simplifies ISO 17025 method validation
Sample Compatibility & Compliance
The H02983 is validated for use with all common TLC stationary phases, including silica gel 60 F254, aluminum oxide, reversed-phase C18, and chiral-selective layers. It accommodates viscous samples (e.g., crude plant extracts, polymer solutions) and low-volume analytes (down to 0.5 µL per spot) without cross-contamination, thanks to its modular tip design and solvent-washable assembly. The instrument conforms to ICH Q5A and USP guidelines for chromatographic system suitability, supporting documented verification of spot geometry, symmetry, and migration consistency. As a Class I non-electrical device under ISO 13485–aligned manufacturing protocols, it requires no CE marking but complies with general laboratory safety standards (ANSI Z88.2–2015 for fume hood compatibility and ISO 14644–1 Class 8 cleanroom handling recommendations).
Software & Data Management
The H02983 operates entirely without embedded software, firmware, or digital interfaces—ensuring full compliance with FDA 21 CFR Part 11 requirements for paper-based record retention in regulated pharmaceutical QC labs. All operational parameters (plate dimensions, spotting coordinates, channel configuration) are recorded manually in lab notebooks or LIMS-integrated worksheets. For laboratories implementing electronic records, optional third-party documentation templates (PDF/Excel) are available for SOP alignment, including blank spot layout grids, calibration log sheets, and daily verification checklists. No data encryption, user authentication, or audit trail functionality is provided—consistent with its designation as a purely mechanical tool under ASTM E2500–13 Annex A2 definitions.
Applications
This spotter is routinely deployed in:
- Pharmaceutical stability studies (ICH Q1A–Q1E), where identical spot morphology across timepoint plates is critical for Rf value comparability
- Herbal medicine fingerprinting per Chinese Pharmacopoeia (ChP) monographs, supporting multi-component qualitative profiling
- Academic teaching labs for undergraduate chromatography instruction—low learning curve, minimal maintenance, and high student throughput
- Preparative TLC fraction collection, where precise spot spacing prevents band overlap during development
- Regulatory submission support for ANDA filings, where manual spotting traceability satisfies FDA Chemistry, Manufacturing, and Controls (CMC) documentation expectations
FAQ
Is the H02983 compatible with glass-backed TLC plates?
Yes—the adjustable stage height and low-profile clamping mechanism accommodate both flexible polyester-backed and rigid glass-supported plates up to 3 mm thickness.
Can spot volume be quantified directly using this instrument?
No. Volume control is achieved externally via calibrated capillaries or syringes; the H02983 ensures positional fidelity only—not volumetric delivery.
Does it require annual calibration certification?
Per ISO/IEC 17025:2017 Clause 6.5.2, mechanical spotters fall under “equipment not requiring formal calibration” if verified daily using reference plates with certified spot patterns.
What cleaning protocol is recommended after use with corrosive solvents?
Rinse spotting tips with methanol followed by nitrogen purge; wipe stage surfaces with lint-free cloth dampened with isopropanol—avoid aqueous cleaners to prevent aluminum oxidation.
Is replacement part support available outside China?
Yes. HengaoDe maintains authorized distributor networks in EU, USA, and ASEAN regions; spare nozzles, clamps, and micrometer assemblies ship within 5 business days under standard terms.