Empowering Scientific Discovery

Apkji AP-GD10 High-Low Temperature Environmental Test Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Apkji
Model AP-GD10
Origin Guangdong, China
Manufacturer Type Direct Manufacturer
Temperature Deviation ±2 °C
Heating Rate ≤60 min (from 25 °C to +150 °C)
Cooling Rate ≤45 min (from 25 °C to −40 °C)
Compliance GB/T 10592–2008, GB/T 2423.1–2008, GB/T 2423.2–2008, GJB 150.3–2009, GJB 150.4–2009, IEC 60068-2-1, IEC 60068-2-2, MIL-STD-810H

Overview

The Apkji AP-GD10 High-Low Temperature Environmental Test Chamber is an engineered thermal stress testing system designed for evaluating the functional integrity and material stability of electronic components, automotive parts, optical devices, and industrial materials under controlled extreme temperature conditions. It operates on a dual-mode thermal control architecture—combining precision PID-regulated resistive heating with a variable-speed, modulating refrigeration circuit—to deliver stable, repeatable thermal profiles across a wide operating range (typically −40 °C to +150 °C). Unlike basic on/off thermal chambers, the AP-GD10 implements continuous compressor power modulation (0–99.99% capacity control), minimizing thermal overshoot and reducing energy consumption by up to 30% compared to conventional heater-balanced systems. Its design adheres to the structural and performance requirements defined in GB/T 10592–2008 and aligns with international environmental test standards including IEC 60068-2-1 (cold), IEC 60068-2-2 (dry heat), and MIL-STD-810H Method 502.7, making it suitable for qualification testing in R&D labs, QC departments, and third-party certification facilities.

Key Features

  • Stainless steel 304 inner chamber construction — corrosion-resistant, thermally fatigue-tolerant, and compatible with long-term cyclic operation
  • High-density polyurethane foam insulation (≥100 mm thickness) — optimized thermal retention and minimized external surface temperature rise
  • Electropolished door seal with high-temperature silicone gasket — achieving leak rate <1.0 × 10−5 mbar·L/s under vacuum-assisted verification
  • Modulating refrigeration system using internationally certified compressors and eco-friendly R404A/R134a blended refrigerant — compliant with EU F-Gas Regulation (EU) No 517/2014
  • Dual-channel independent temperature monitoring — one for chamber air (PT100 Class A sensor), one for sample zone (optional RTD probe input)
  • Integrated over-temperature, over-current, and phase-failure protection — meeting IEC 61000-6-2 EMC immunity and IEC 61000-6-4 emission requirements
  • Standard Ethernet (RJ45) and USB 2.0 interfaces — enabling remote supervision, data logging, and integration with MES/LIMS platforms

Sample Compatibility & Compliance

The AP-GD10 accommodates samples up to 500 mm × 500 mm × 500 mm (W×D×H) within its stainless-steel working chamber. Optional through-wall ports (Φ50 mm, Φ100 mm) support real-time electrical signal feedthrough or pneumatic/hydraulic line routing during active thermal cycling. The chamber satisfies mandatory test protocols for reliability validation per GB/T 2423.1 (cold), GB/T 2423.2 (dry heat), GB/T 2423.3 (constant damp heat), and GB/T 2423.4 (cyclic damp heat). It also supports military-grade environmental stress screening per GJB 150.3 (low temperature) and GJB 150.4 (high temperature), as well as aerospace-relevant thermal shock profiling when operated in conjunction with external programmable controllers. All calibration procedures follow ISO/IEC 17025 traceable methodologies, and temperature uniformity is verified per GB/T 5170.1–2008 (±2 °C at any point within the working volume).

Software & Data Management

The embedded controller runs a deterministic real-time OS with dual-mode operation: manual setpoint mode and multi-segment programmable ramp-soak cycling (up to 99 segments, 999 cycles). All thermal profiles—including ramp rates, dwell durations, and transition logic—are stored in non-volatile memory with timestamped audit trails. Optional data logging records chamber air temperature, setpoint, compressor status, and alarm events at user-defined intervals (1 s to 60 min resolution) onto internal SD card or network storage. Export formats include CSV and PDF reports compliant with FDA 21 CFR Part 11 requirements when paired with optional electronic signature and role-based access modules. Remote monitoring via Modbus TCP or HTTP API enables integration into centralized lab infrastructure management systems without proprietary middleware.

Applications

  • Functional validation of PCBAs, IC packages, and passive components under thermal cycling (e.g., JEDEC JESD22-A104 qualification)
  • Thermal aging studies of polymer encapsulants, conformal coatings, and adhesive bonds used in automotive ECUs
  • Environmental stress screening (ESS) of LED modules and driver electronics prior to burn-in
  • Material coefficient of thermal expansion (CTE) correlation testing for optoelectronic subassemblies
  • Pre-compliance testing for IEC 60068-2 series and MIL-STD-810H thermal procedures in contract laboratories
  • Process development support for solder reflow profile optimization and thermal interface material (TIM) performance evaluation

FAQ

What temperature range does the AP-GD10 support?
The standard operating range is −40 °C to +150 °C. Custom configurations are available for extended low-temperature (−70 °C) or high-temperature (+200 °C) variants upon request.
Is the chamber suitable for humidity-controlled testing?
No—the AP-GD10 is a dry-thermal-only chamber. For combined temperature/humidity testing, refer to Apkji’s AP-GDS series (GB/T 10586–2006 compliant).
Can test data be exported for regulatory submission?
Yes. With optional audit trail and electronic signature modules enabled, CSV logs and PDF reports meet GLP/GMP documentation requirements and are admissible in FDA, CE, and CNAS submissions.
What safety certifications does the unit carry?
It conforms to GB 4793.1–2007 (safety requirements for electrical equipment for measurement, control, and laboratory use) and carries CCC mark. UL/CSA certification is available under OEM agreement.
Is remote firmware update supported?
Firmware updates require local USB media upload; no over-the-air (OTA) capability is provided due to deterministic control architecture requirements.