| Brand | Aria |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Models | AF101, AF111 |
| Wind Speed Range | 0.01–30 m/s |
| Temperature Range | −20–70 °C |
| Relative Humidity Range | 2–98 %RH |
| Wind Speed Resolution | 0.01 m/s (0.1 m/s above 10.0 m/s) |
| Accuracy | ±2 % or ±0.05 m/s (whichever is greater), ±0.5 °C, ±3 %RH |
| Operating Environment | −20–70 °C (non-condensing), 2–98 %RH |
| Response Time | 90 % in ≤1 s (wind speed 0–1 m/s), ≤60 s (RH, still air) |
| Power | 2 × AA alkaline batteries (approx. 20 h at 5 m/s, 20 °C) |
| Weight | 150 g (AF101), 175 g (AF111), incl. batteries |
| Communication | Bluetooth 4.0+, up to ~5 m line-of-sight |
| Probe | I/L dual-mode telescopic probe with mm scale markings |
| Mounting | 1/4″-20 tripod thread (also functions as hanging lug) |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Model | APS100 Series |
| Flow Rate | 2.83 L/min (1 CFM) ±5% |
| Timing Accuracy | ≤±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Particle Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Counting Efficiency | 0.3 μm (50±20)%, 0.5 μm (100±10)%, 1.0 μm (100±10)% |
| Max. Concentration | 5×10⁷ particles/m³ (≤10% coincidence loss) |
| Zero Count Level | <1 count per 5 minutes |
| Light Source | Long-life laser diode |
| Communication | Modbus RTU |
| Analog Output | 4–20 mA (dual-channel configurable) |
| Power Supply | 12–24 VDC |
| Operating Environment | 5–35 °C, 20–95% RH (non-condensing) |
| Housing Material | SUS316L stainless steel |
| Dimensions (APS100) | 107×56×49 mm |
| Weight (APS100) | ~420 g |
| Warranty | 2 years (excludes internal pump) |
| Brand | Aira |
|---|---|
| Origin | Japan |
| Model | AF303 (Omnidirectional Spherical Probe) / AF304 (Directional Probe) |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50 m/s |
| Accuracy | ±2% of reading or ±0.05 m/s, whichever is greater |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 5–24 VDC, P ≥ 5 W |
| Analog Output | 4–20 mA (max. load 300 Ω) or 1–5 V |
| Digital Output | RS-485 |
| Probe Cable Length Options | 1000 / 2000 / 3000 mm |
| Output/Power Cable Length Options | 2000 / 3000 mm |
| Probe Type | AF303 — omnidirectional spherical sensor |
| Enclosure Compatibility | Designed for wall-mount or duct-integrated installation in clean-air environments |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Model | AP133 / AP136 |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | Low-flow (2.83 L/min) |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1 s per 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Channel Count | 3 or 6 channels |
| Particle Size Range | 0.3–5.0 μm (AP133) / 0.3–10.0 μm (AP136) |
| Counting Efficiency | 50% at 0.3 μm, ≥99% at ≥0.45 μm (compliant with ISO 21501-4 & JIS B 9921) |
| Zero Count Level | <1 count per 5 minutes (ISO 21501-4 compliant) |
| Max. Concentration | 4×10⁶ particles/m³ (5% counting loss), up to 2.1×10⁸ particles/m³ with correction |
| Laser Source | Long-life laser diode |
| Resolution at 0.5 � | m: <15% (ISO 21501-4) |
| Sampling Modes | Manual, Auto, ISO-compliant (ISO 14644-1), GMP-compliant (EU Annex 1), Accumulative/Differential, Count/Concentration |
| Sampling Time | 1 s – 2 h (configurable) |
| Hold Time | 0 s – 2 h (configurable) |
| Sampling Cycles | 1–9999 (AP136) / 1–2000 (AP133) or continuous |
| Sampling Points | 1–100 |
| Room ID | 0–99 |
| Delay Start | 10 s (Manual/Auto), 1 min – 2 h (ISO/GMP) |
| Internal Filter | High-efficiency air filter |
| Pump | Integrated diaphragm pump |
| Communication Interfaces | LAN (RJ45), Bluetooth Low Energy (BLE), USB-B, USB-C |
| Remote Control | Ethernet & BLE |
| Data Storage | 15,000 records (AP136) / 10,000 records (AP133) |
| Security | Password-protected login |
| Alarms | Audible particle count alarm, low battery, flow fault, laser fault |
| Display | Resistive touch screen + single physical button |
| Power Supply | AC adapter (100–240 VAC, output 5 V / 3 A) |
| Battery | Li-ion (5000 mAh), ~4 h continuous operation |
| Charging Time | ~4.5 h |
| Dimensions (main unit) | H 19.7 × W 9.2 × D 4.8 cm |
| Probe length | ~3 cm |
| Weight | ~810 g |
| Operating Environment | 5–35 °C, 20–95% RH (non-condensing) |
| Storage | −20–50 °C, ≤98% RH (non-condensing) |
| Warranty | 2 years |
| Standard Accessories | AC adapter, USB cable, zero-count filter, remote measurement software, calibration certificate, carrying case |
| Optional Accessories | Temperature & relative humidity probe (0–50 °C, ±0.5 °C |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1, EU GMP Annex 1 (Grade A–D static/dynamic), USP <788>, FDA 21 CFR Part 11 (audit trail enabled via PC software) |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Model | APS200 Series |
| Flow Rate | 28.3 L/min (1 CFM) ±5% |
| Timing Accuracy | ≤±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Counting Efficiency | 0.3 µm (50±20)%, 0.5 µm ≥(100±10)%, 1.0 µm ≥(100±10)% |
| Max Concentration | 20,000,000 particles/m³ (<10% counting loss) |
| Zero Count Level | <1 count per 5 minutes |
| Light Source | Long-life laser diode |
| Communication | Modbus TCP/IP or Modbus RTU |
| Analog Output | 4–20 mA (2-channel configurable) |
| Power Supply | 12–24 VDC |
| Operating Environment | 5–35 °C, 20–95% RH (non-condensing) |
| Storage Environment | −20–50 °C, ≤98% RH (non-condensing) |
| Housing Material | SUS316L stainless steel |
| Dimensions (APS200) | ~195 × 110 × 100 mm |
| Weight (APS200) | ~1700 g |
| Warranty | 2 years (excludes internal pump) |