BrandAria
OriginJapan
Instrument TypeThermal Anemometer
ModelsAF101, AF111
Wind Speed Range0.01–30 m/s
Temperature Range−20–70 °C
Relative Humidity Range2–98 %RH
Wind Speed Resolution0.01 m/s (0.1 m/s above 10.0 m/s)
Accuracy±2 % or ±0.05 m/s (whichever is greater), ±0.5 °C, ±3 %RH
Operating Environment−20–70 °C (non-condensing), 2–98 %RH
Response Time90 % in ≤1 s (wind speed 0–1 m/s), ≤60 s (RH, still air)
Power2 × AA alkaline batteries (approx. 20 h at 5 m/s, 20 °C)
Weight150 g (AF101), 175 g (AF111), incl. batteries
CommunicationBluetooth 4.0+, up to ~5 m line-of-sight
ProbeI/L dual-mode telescopic probe with mm scale markings
Mounting1/4″-20 tripod thread (also functions as hanging lug)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAria
OriginJapan
ModelAPS100 Series
Flow Rate2.83 L/min (1 CFM) ±5%
Timing Accuracy≤±1 s over 6-min sampling
Repeatability≤±10% FS
Particle Size Distribution Error≤±30%
Indication Error≤±30% FS
Counting Efficiency0.3 μm (50±20)%, 0.5 μm (100±10)%, 1.0 μm (100±10)%
Max. Concentration5×10⁷ particles/m³ (≤10% coincidence loss)
Zero Count Level<1 count per 5 minutes
Light SourceLong-life laser diode
CommunicationModbus RTU
Analog Output4–20 mA (dual-channel configurable)
Power Supply12–24 VDC
Operating Environment5–35 °C, 20–95% RH (non-condensing)
Housing MaterialSUS316L stainless steel
Dimensions (APS100)107×56×49 mm
Weight (APS100)~420 g
Warranty2 years (excludes internal pump)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAira
OriginJapan
ModelAF303 (Omnidirectional Spherical Probe) / AF304 (Directional Probe)
Instrument TypeThermal Anemometer
Resolution0.01 m/s
Measurement Range0.01–50 m/s
Accuracy±2% of reading or ±0.05 m/s, whichever is greater
Operating Temperature−20 to +70 °C
Operating Humidity0–95% RH (non-condensing)
Power Supply5–24 VDC, P ≥ 5 W
Analog Output4–20 mA (max. load 300 Ω) or 1–5 V
Digital OutputRS-485
Probe Cable Length Options1000 / 2000 / 3000 mm
Output/Power Cable Length Options2000 / 3000 mm
Probe TypeAF303 — omnidirectional spherical sensor
Enclosure CompatibilityDesigned for wall-mount or duct-integrated installation in clean-air environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAria
OriginJapan
ModelAP133 / AP136
Instrument TypeHandheld Particle Counter
Flow RateLow-flow (2.83 L/min)
Flow Accuracy≤ ±5%
Timing Accuracy≤ ±1 s per 6-min sampling
Repeatability≤ ±10% FS
Size Distribution Error≤ ±30%
Indication Error≤ ±30% FS
Channel Count3 or 6 channels
Particle Size Range0.3–5.0 μm (AP133) / 0.3–10.0 μm (AP136)
Counting Efficiency50% at 0.3 μm, ≥99% at ≥0.45 μm (compliant with ISO 21501-4 & JIS B 9921)
Zero Count Level<1 count per 5 minutes (ISO 21501-4 compliant)
Max. Concentration4×10⁶ particles/m³ (5% counting loss), up to 2.1×10⁸ particles/m³ with correction
Laser SourceLong-life laser diode
Resolution at 0.5 �m: <15% (ISO 21501-4)
Sampling ModesManual, Auto, ISO-compliant (ISO 14644-1), GMP-compliant (EU Annex 1), Accumulative/Differential, Count/Concentration
Sampling Time1 s – 2 h (configurable)
Hold Time0 s – 2 h (configurable)
Sampling Cycles1–9999 (AP136) / 1–2000 (AP133) or continuous
Sampling Points1–100
Room ID0–99
Delay Start10 s (Manual/Auto), 1 min – 2 h (ISO/GMP)
Internal FilterHigh-efficiency air filter
PumpIntegrated diaphragm pump
Communication InterfacesLAN (RJ45), Bluetooth Low Energy (BLE), USB-B, USB-C
Remote ControlEthernet & BLE
Data Storage15,000 records (AP136) / 10,000 records (AP133)
SecurityPassword-protected login
AlarmsAudible particle count alarm, low battery, flow fault, laser fault
DisplayResistive touch screen + single physical button
Power SupplyAC adapter (100–240 VAC, output 5 V / 3 A)
BatteryLi-ion (5000 mAh), ~4 h continuous operation
Charging Time~4.5 h
Dimensions (main unit)H 19.7 × W 9.2 × D 4.8 cm
Probe length~3 cm
Weight~810 g
Operating Environment5–35 °C, 20–95% RH (non-condensing)
Storage−20–50 °C, ≤98% RH (non-condensing)
Warranty2 years
Standard AccessoriesAC adapter, USB cable, zero-count filter, remote measurement software, calibration certificate, carrying case
Optional AccessoriesTemperature & relative humidity probe (0–50 °C, ±0.5 °C
ComplianceISO 21501-4, JIS B 9921, ISO 14644-1, EU GMP Annex 1 (Grade A–D static/dynamic), USP <788>, FDA 21 CFR Part 11 (audit trail enabled via PC software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAria
OriginJapan
ModelAPS200 Series
Flow Rate28.3 L/min (1 CFM) ±5%
Timing Accuracy≤±1 s over 6-min sampling
Repeatability≤±10% FS
Size Distribution Error≤±30%
Indication Error≤±30% FS
Counting Efficiency0.3 µm (50±20)%, 0.5 µm ≥(100±10)%, 1.0 µm ≥(100±10)%
Max Concentration20,000,000 particles/m³ (<10% counting loss)
Zero Count Level<1 count per 5 minutes
Light SourceLong-life laser diode
CommunicationModbus TCP/IP or Modbus RTU
Analog Output4–20 mA (2-channel configurable)
Power Supply12–24 VDC
Operating Environment5–35 °C, 20–95% RH (non-condensing)
Storage Environment−20–50 °C, ≤98% RH (non-condensing)
Housing MaterialSUS316L stainless steel
Dimensions (APS200)~195 × 110 × 100 mm
Weight (APS200)~1700 g
Warranty2 years (excludes internal pump)