Amino Acid Analyzers
Filter
Showing all 16 results
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BioLogic DuoFlow System |
| Maximum Pressure | 3500 psi (23 MPa) |
| Flow Rate Range | 0.01–80 mL/min (configurable via pump head selection) |
| UV Detection Wavelengths | Fixed 254/280 nm |
| Conductivity Range | 1–500 mS/cm |
| UV Sensitivity | 0.0001–2.0 OD |
| Fraction Collection Modes | Time-based (0.03–999 min), Drop-based (0–9999 drops), Volume-based, Large-volume (20 positions, up to 500 mL each) |
| Temperature-Controlled Operation | Compatible with chromatography cold cabinets (4–10 °C) |
| System Biocompatibility | Fully bio-inert fluidic path (PEEK, titanium, sapphire, fused silica) |
| Software Platform | BioLogic System Controller v5.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biochrom 30+ |
| Price Range | USD 92,000 – 132,000 (based on exchange rate and configuration) |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–130 mL/hr |
| Maximum Pump Pressure | 45 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control | 4 °C to ambient, continuously adjustable |
| Post-Column Reactor Temperature Range | 40–145 °C |
| Detection Wavelengths | 570 nm and 440 nm (dual-wavelength, self-calibrating, parallel signal output with summation capability) |
| Flow Cell Volume | 8 µL |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | LA8080 |
| Pump Flow Rate | 0.000–1.000 mL/min |
| Maximum Pump Pressure | 34 MPa |
| Autosampler Injection Volume | 0–100 µL |
| Autosampler Temperature Control | 4 °C and 10 °C |
| Post-Column Reactor Temperature Range | 50–140 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | HiTech |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HT-1010 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–100 µL |
| Autosampler Temperature Control | 4–25 °C (optional) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | L-3000 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +5 °C (±1 °C) to 70 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detector Wavelength Range | 190–800 nm |
| Flow Cell Volume | 8 µL |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | L-3000plus |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pump Pressure | 6000 psi (41.4 MPa) |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +5 °C (±1 °C) to 70 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelength Range | 190–800 nm |
| Flow Cell Volume | 8 µL |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | L-3000pro |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 1–500 µL |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelength Range | 190–800 nm |
| Flow Cell Volume | 4 µL |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Post-Column Derivatization System |
| Model | Anters-1500A |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control Range | 5–70 °C |
| Post-Column Reactor Temperature Range | Ambient to 199 °C |
| Detection Wavelength | 570 nm (dual-wavelength detection at 440 nm & 570 nm) |
| Flow Cell Volume | 8 µL |
| Brand | LABA (Tianjin Lab-Automation) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Brand | Lab-Antech (formerly LABA Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| System Model | AA9800 |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | AA9800 Plus |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AA9800 Series |
| Price Range | USD 70,000–100,000 |
| Analyzer Type | Post-Column Derivatization |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Artemis 6000 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.01–10.0 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–500 µL |
| Autosampler Temperature Control | Yes |
| Post-Column Reactor Temperature Range | Ambient to 180 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Essentia LC-16AAA |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.00 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0.1–100 µL |
| Autosampler Temperature Control | Ambient |
| Post-Column Reactor Temperature Range | (Ambient + 10 °C) to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm (full range: 190–700 nm) |
| Flow Cell Volume | 8 µL |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | AAA-Direct |
| Pricing | Upon Request |
| Pump Material | PEEK (chemically inert, pH 0–14 compatible) |
| Pump Type | Tandem dual-piston, constant stroke |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | <0.1% at 1.0 mL/min |
| Flow Precision | <0.1% RSD at 1.0 mL/min |
| Pressure Range | 50–5000 psi |
| Pressure Pulsation | ≤1% |
| Gradient Ratio Accuracy | ±0.5% at 2.0 mL/min |
| Gradient Ratio Precision | ±0.5% RSD at 2.0 mL/min |
| Eluent Options | Isocratic: 1 |
| Gradient | up to 4 |
| Gradient Delay Volume | <400 µL |
| EG Concentration Range | 0.01–100 mM |
| EG Compatible Eluents | KOH, LiOH, NaOH, CO₃²⁻/HCO₃⁻, CO₃²⁻, MSA |
| EG Concentration Increment | 0.01 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| Max EG Operating Pressure | 3000 psi (21 MPa) |
| Organic Solvent Tolerance | Anion mode: ≤25% methanol |
| Cation mode | solvent-free aqueous only |
| Operating Temperature | 4–40 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Dimensions (H×W×D) | 41×23×56 cm |
| Weight | 25 kg |
| Power | 90–265 V AC, 47–63 Hz |
| Ion Reservoir Dimensions | 23×7×10 cm, 1.6 kg |
| Cr-TC Trap Column | 3.8×3.8×5.8 cm, 60 g |
| Eluent Organizer (EO) | Holds four 1–2 L or two 4 L chemically resistant PE/epoxy-coated bottles |