| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Advanced Instruments, Inc. |
| Type | Imported |
| Model | Anoxomat III |
| Pricing | Upon Request |
| Brand | Chuanhong |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKST-2 |
| Price | Upon Request |
| Chamber Material | 3 mm SUS304 Stainless Steel |
| Viewing Window | 8–10 mm Tempered Glass |
| Gas Valves | 304 Stainless Steel Ball Valves with Integrated Inlet/Outlet Fittings |
| Internal Lighting | UV-Free White LED |
| Power Supply | Multi-Port Industrial Socket (220 V AC) |
| Gloves | Industrial-Grade Acid-Resistant Latex with O-Ring Seals |
| Optional Upgrades | KF-25/KF-40 Vacuum Flange Interfaces |
| Main Chamber Dimensions (W×D×H) | 600 × 450 × 420 mm |
| Transfer Airlock Options | Ø210 mm / 240 L / 260 L Cylindrical Designs |
| Door Mechanism | Semi-Automatic Hinged Door |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator |
| Oxygen Concentration | <0.1% O₂ (maintained via catalytic deoxygenation and gas replacement) |
| Temperature Control Range | RT+3°C to 50°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Gas Supply | Pre-mixed anaerobic gas (85% N₂ / 10% H₂ / 5% CO₂ |
| Cultivation Chamber Dimensions (W×D×H) | 200 × 190 × 260 mm |
| Operation Chamber Dimensions (W×D×H) | 760 × 630 × 620 mm |
| External Dimensions (W×D×H) | 1200 × 730 × 1330 mm |
| Power Supply / Rated Power | 220 V, 50 Hz / 600 W |
| Anaerobic Establishment Time (Operation Chamber) | <60 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Vacuum Sampling Chamber Deoxygenation Time | <5 min |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | YQX-II |
| Price Range | USD 1,400–2,800 (FOB) |
| Temperature Control Range | Ambient +3°C to 50°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Anaerobic Chamber Establishment Time (Operation Room) | <60 min |
| Sample Transfer Chamber Anaerobiosis Achievement Time | <5 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Chamber Dimensions (D×W×H) | 800×550×650 mm |
| Overall Dimensions (D×W×H) | 1200×730×1300 mm |
| Power Supply | 220 V, 50 Hz / 600 W |
| Gas Mixture Ratio | N₂ 85% / H₂ 5% / CO₂ 10% |
| Nitrogen Purity | ≥99.9% |
| UV Sterilization Lamp | Integrated |
| Stainless Steel Construction | 304 SS for Chamber Walls & Transfer Port |
| Viewing Window | Impact-Resistant Tempered Glass with Dual-Sealed Glove-Free Sleeve Ports |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator with Microaerophilic Capability |
| Oxygen Concentration Range | ≤1% (Anaerobic) / Adjustable 2–10% (Microaerophilic) |
| Temperature Control Range | Ambient +3°C to 50°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| Operating Chamber Dimensions | 800 × 550 × 650 mm (W×D×H) |
| Gas Supply Options | Single-gas (premixed 10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (pure N₂ + premixed gas) |
| Deoxygenation Time (Operation Chamber) | <60 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Power Supply | 220 V, 50 Hz / 1000 W |
| UV Sterilization Lamp | Integrated |
| Catalytic Oxygen Scrubber | Built-in |
| Casters with Locking Brakes | Yes |
| Compliance | Designed for ISO 13485-aligned lab workflows |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SYQX-II |
| Price | ¥28,800 |
| Temperature Control Range | RT+3°C to 65°C |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1°C |
| Anaerobic Chamber Stabilization Time (Operation Chamber) | <1 hour |
| Anaerobic Chamber Maintenance Duration (without gas replenishment) | >12 hours |
| Sample Chamber Anaerobiosis Achievement Time | <5 minutes |
| Power Supply/Power Consumption | 220 V, 50 Hz / 600 W |
| Inner Chamber Dimensions (W×D×H) | 680 × 190 × 200 mm |
| Overall Dimensions (W×D×H) | 1200 × 1400 × 700 mm |
| Construction Material | Stainless Steel (304) |
| Viewing Window | Impact-Resistant Tempered Glass |
| Glove Ports | Dual Integrated Ethylene Propylene Diene Monomer (EPDM) Gloves |
| Internal UV Sterilization Lamp | Yes |
| Catalytic Oxygen Scavenger System | Yes |
| Gas Inlet with Adjustable Flow Control Valve | Yes |
| Wax Sealing Sterilizer | Integrated |
| Hot-Wire Inoculation Loop Sterilizer | Built-in |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Anaerobic Incubator |
| Operating Temperature Range | RT + 3°C to 65°C |
| Temperature Uniformity & Stability | ±0.5°C |
| Oxygen Concentration Range | 0.1–25% (displayable in % or ppm) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Gas System | Dry, oil-free vacuum pump |
| Anaerobic Performance | O₂ ≤ 1% achievable |
| Control Interface | Full-color capacitive touchscreen with real-time O₂/temperature display, local atmospheric pressure readout, and touch-activated solenoid valve control |
| Safety Features | Over-temperature alarm (audible/visual), auto power recovery with parameter memory, UV sterilization lamp, 12 mm tempered front window, 304 stainless steel inner chamber |
| Compliance Enablers | Supports GLP/GMP documentation workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | ACW-350Pro |
| Instrument Type | Manual Anaerobic Incubator |
| Temperature Range | RT+3°C to 65°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| O₂ Concentration Range | 0.1–25% (displayable in % or ppm) |
| Gas Supply | Mixed gas (e.g., 85% N₂ / 5% H₂ / 10% CO₂ or 99.99% N₂) |
| Chamber Dimensions (W×D×H) | 400 × 300 × 280 mm |
| Vacuum Pump | Oil-free dry piston pump |
| Anaerobic Maintenance Time | >12 h after gas supply cessation |
| Viewing Window | 12 mm tempered glass |
| Interior Material | 304 stainless steel |
| Power Supply | 220 V, 50 Hz |
| Input Power | 650 W |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Model | ACW-350Pro-II |
| Temperature Range | RT + 3°C to 65°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| O₂ Concentration Range | 0.1–25% (displayable in % or ppm) |
| Gas Supply | Pre-mixed gas (5% H₂ + 10% CO₂ + 85% N₂) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Internal Chamber Material | 304 Stainless Steel |
| Viewing Window | 12 mm Tempered Glass |
| Vacuum Pump | Oil-free Dry Diaphragm Pump |
| Power Supply | 220 V, 50 Hz |
| Input Power | 650 W |
| Anaerobic Maintenance Duration | >12 h after gas supply cessation |
| Oxygen Reduction Time (Transfer Chamber) | ≤5 min |
| Oxygen Reduction Time (Main Chamber) | ≤50 min |
| UV Sterilization | Integrated |
| Touchscreen Interface | Full-color capacitive touchscreen with real-time atmospheric pressure display |
| Compliance | Designed for GLP-compliant workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Temperature Range | RT + 3°C to 52°C |
| Temperature Uniformity & Fluctuation | ±0.3°C |
| Humidity Range | 20–90% RH |
| O₂ Concentration Range | 0–100% |
| Gas Supply | Anaerobic gas mixture (80% N₂, 10% CO₂, 10% H₂) and pure N₂ |
| Chamber Dimensions (W×D×H) | 490 × 760 × 530 mm |
| O₂ Detection Resolution | 0.1% |
| O₂ Control Accuracy | ±0.1% |
| Catalyst Lifetime | >3 years without thermal activation |
| Anaerobic Equilibration Time | ≤30 min to ≤5 ppm O₂ |
| Transfer Lock Capacity | 6 L chamber (supports 22 × 90 mm Petri dishes or 3 × 500 mL screw-cap bottles) |
| UV Sterilization | 254 nm integrated lamp with programmable timing |
| Filtration | HEPA-grade air filtration system |
| Data Logging | 45-day internal history storage with USB export capability |
| Safety Interlocks | Dual-door pneumatic seal with vacuum-assisted gasket, mechanical/electronic interlock logic |
| Validation Interface | Standardized 4–20 mA / RS485 ports for third-party probe integration |
| Operating System | Bilingual (Simplified Chinese & English), three-tier user permission management |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Model | ZAI-350-II |
| Temperature Range | RT+3°C to 60°C |
| Temperature Uniformity & Fluctuation | ±1°C |
| Oxygen Concentration Range | 0.1–20% (v/v) |
| Gas Supply Options | Single-gas (premixed anaerobic gas: 5% H₂ + 10% CO₂ + 85% N₂) or dual-gas (separate N₂ and premixed gas cylinders) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Anaerobic Maintenance Duration | >12 h after gas supply cessation |
| Vacuum Pump | Oil-free dry diaphragm pump |
| Viewing Window | 12 mm tempered glass |
| Interior Material | 304 stainless steel |
| UV Sterilization | Integrated germicidal lamp |
| Control Interface | LCD display with touch-enabled operation (ZAI-350-II variant includes real-time O₂ % readout and local atmospheric pressure monitoring) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Model | ZAI-350R |
| Temperature Range | 4–60°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| O₂ Concentration Range | 0.1–25% |
| Gas Supply | Pre-mixed Gas (5% H₂ + 10% CO₂ + 85% N₂) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Operating Voltage | 220 V, 50 Hz |
| Power Consumption | 650 W |
| Anaerobic Maintenance Duration | >12 h (after gas supply cessation) |
| Vacuum Pump | Oil-free dry diaphragm pump |
| Viewing Window | 725 × 275 mm tempered glass (12 mm thick) |
| Construction | 304 stainless steel inner chamber, cold-rolled steel outer shell with electrostatic powder coating |
| Brand | JU CHUANG ENVIRONMENTAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JC-QX-II |
| Instrument Type | Automated Anaerobic Incubation & Manipulation System |
| Operating Oxygen Concentration | ≤1% (in anaerobic mode) |
| Temperature Range | +3°C to 60°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability (Fluctuation) | ±0.3°C |
| Humidity Control | 90% ±5% RH |
| Gas Supply | 99.99% Nitrogen or Custom Anaerobic Gas Mix (5% H₂ / 10% CO₂ / 85% N₂) |
| Chamber Dimensions (W×D×H) | 81.4 × 66.4 × 66.8 cm |
| Anaerobic Transition Time (Sample Chamber) | ≤5 min |
| Anaerobic Transition Time (Main Chamber) | ≤60 min |
| Anaerobic Maintenance Duration (Gas-Off Mode) | >12 h |
| Compliance | GB/T 18268.1–2010, GB 4824 Class B Group 1 |