BrandAoma
OriginAnhui, China
ModelOM3000
Detection LimitsFID: 0.5 ppm methane
PID0.5 ppm isobutylene
DetectorsFID, PID, CH₄, O₂, CO, CO₂ (optional)
RangeFID: 0–50,000 ppm methane
PID0.5–2,000 ppm isobutylene
Response Time≤3.5 s (90% of final value)
Repeatability & Accuracy≤2% for both FID (methane) and PID (isobutylene)
Preheat Time≤20 min
Operating Temp−10°C to +50°C
RH0–95% RH
Sample Flow0.1–3.0 L/min (adjustable, nominal 1 L/min at probe inlet)
H₂ Cylinder100 mL, rated to 2200 psi (15.3 MPa), ≥12 h runtime
Battery Life≥10 h at ambient temperature
Dimensions229 × 200 × 74 mm
Weight≤2.5 kg
Ingress ProtectionIP66
Explosion ProtectionMain unit: Ex db[ia Ga] IIC T4 Gb
Handheld controllerEx ib IIC T4 Gb
ConnectivityBluetooth/Wi-Fi
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAoma
OriginAnhui, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelMINI FID M2
Detection PrincipleFlame Ionization Detection (FID)
Detection TargetTotal Hydrocarbons (THC), Methane (CH₄), and Volatile Organic Compounds (VOCs)
Detection Limit0.5 ppm methane (defined as 7× baseline noise SD)
Measurement Accuracy±2% of reading (1.0–10,000 ppm CH₄)
Detector TypeMicro-FID with Low-Temperature Co-fired Ceramic (LTCC) Core
CalibrationAuto-zero & multi-point manual calibration (≥2 points)
Response Time (T90)<2.0 s (10,000 ppm CH₄)
Preheat Time≤5 min
Operating Temperature−25°C to +50°C
Relative Humidity0–95% RH (non-condensing)
Ingress ProtectionIP66 (GB/T 4208)
Explosion ProtectionEx db ia IIC T4 Gb (GB/T 3836.1–4:2021)
Power Supply7.4 V Li-ion battery (5000 mAh)
Weight0.9 ± 0.05 kg
Dimensions320 × 92 × 66 mm
Data Storage8 GB internal flash
ConnectivityBluetooth 5.0, Wi-Fi 2.4 GHz, USB 2.0
Hydrogen SourceSolid-state metal hydride cartridge (0.1–1.0 MPa operating pressure
Sampling Flow0.1–1.0 L/min (nominal 0.7 L/min)
Linearity Error±2% full scale
Repeatability±2% (500 ppm CH₄)
Drift≤±5% over 8 h continuous operation
Resolution0.01 μmol/mol
Unitsppm, ppb, mg/m³, μmol/mol (user-selectable & export-consistent)
Regulatory ComplianceHJ 1012–2018, HJ 1230–2021, HJ 733–2014, GB 37822–2019
Functional SafetySIL-certified architecture
Optional SensorsPID, O₂, CO, SO₂, H₂S, CO₂
Software IntegrationLDAR Management APP, VOCs Inspection APP, Cloud-based LDAR Platform (with audit trail), RFID-enabled instrument lifecycle management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAoma
ModelMINI FID X5
Detection PrincipleFlame Ionization Detection (FID) + Photoionization Detection (PID)
Detection LimitsFID – 0.5 ppm methane
Detector OptionsFID (standard), PID/O₂/CO/CO₂/H₂S (optional)
Operating Temperature−20 °C to +60 °C
Relative Humidity0–95% RH
Explosion ProtectionEx db ia IIC T4 Gb
IP RatingIP66
Weight (incl. battery & hydride cartridge)1.4 ± 0.05 kg
Dimensions267 × 172 × 98 mm
Sampling Flow Rate0.7 L/min (nominal)
Preheat Time≤5 min
Battery Life~10 h (25 °C), ≥4 h (−20 °C)
Data Storage32 GB internal flash (expandable to 128 GB)
ConnectivityWi-Fi, Bluetooth, USB 2.0
Display3.5″ color LCD touchscreen (640 × 480 px)
Hydrogen SourceLow-pressure solid-state metal hydride cartridge (0.3–0.75 MPa, 99.99% H₂, ~10 L equivalent capacity)
CalibrationMulti-point, user-configurable, ≥2 points
AccuracyFID ±2% of reading (1–10,000 ppm CH₄)
RepeatabilityFID ±2% (500 ppm CH₄)
Stability≤±3% drift over 4 h continuous operation
Response Time (T90)FID <2.5 s (10,000 ppm CH₄)
Resolution0.01 μmol/mol
ComplianceHJ 1012–2018, HJ 1230–2021, HJ 733–2014, GB 37822–2019, GB/T 3836–2021
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Aoma
ModelOM3500
Detection PrincipleFlame Ionization Detection (FID) and optional Photoionization Detection (PID)
Detection LimitFID: 0.5 ppm methane
PID0.5 ppm isobutylene
Detector OptionsFID (standard), PID (optional)
Measurement RangeFID: 0–50,000 ppm methane
PID0.5–2,000 ppm isobutylene
Response Time (90%)≤3.5 s (FID @ 10,000 ppm CH₄
Repeatability & Accuracy≤2% RSD for both FID (methane) and PID (isobutylene)
Preheat Time≤20 min
Operating Temperature−10 °C to +50 °C
Relative Humidity0–95% RH (non-condensing)
Sample Flow Rate0.1–3.0 L/min (adjustable, nominal 1.0 L/min at probe inlet)
Hydrogen Supply20 L solid-state metal hydride cartridge (≥12 h runtime at ambient temp)
Battery6400 mAh Li-ion (≥8 h runtime at ambient temp)
Data Storage4 GB internal
Display3.5-inch capacitive touchscreen
CommunicationBluetooth 5.0, Wi-Fi 802.11 b/g/n, USB 2.0
Explosion ProtectionEx db ib IIC T4 Gb
Weight≤1.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOMA
OriginAnhui, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelMINI FID M3
PriceUpon Request
Detection Limit0.5 ppm methane (defined as 7× peak-to-peak noise standard deviation)
Detector TypesFID (primary), with optional PID, O₂, CO, SO₂, H₂S sensors