- All
- Favorite
- Popular
- Most rated
| Brand | GKINST |
|---|---|
| Model | DAC-HTP700 |
| Origin | Anhui, China |
| Press Type | BX90 (optional) |
| Press Material | Inconel 718 superalloy |
| Temperature Range | RT to 700 °C |
| Temperature Control Accuracy | ±1 °C |
| DAC Components | Tungsten Carbide gasket, Type-Ia diamond anvils |
| Temperature Regulation | PID dynamic feedback control |
| Thermocouple | K-type |
| Vacuum Chamber Leak Rate | <1×10⁻⁸ Pa·L/s |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | D7 Mate |
| Price Range | USD 28,000 – 140,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | 600 W / 1200 W (Selectable) |
| Angular Accuracy | ±0.0001° |
| High-Voltage Generator | 40 kV / 600 W or 40 kV / 1200 W |
| Target Materials | Cu, Cr, Mo |
| Goniometer Geometry | Horizontal θ/2θ or ω/θ |
| Goniometer Radius | 150 mm |
| Angular Range | −3° to 152° (140° with automatic beam-defining slit) |
| Repeatability | <0.0001° (2σ) |
| Detector | 640-channel 1D silicon strip detector, active area 32 mm × 8 mm |
| Cooling | Integrated recirculating water chiller (standard), optional external chiller interface |
| Beam Path | Air-scatter suppression module with motorized divergence slit and automatic anti-scatter device |
| Sample Stages | Fixed stage, in-situ heating stage, multi-axis rotating stage, capillary stage, thin-film stage, multifunctional stage, pouch-cell battery stage, high-throughput 8-position rotary stage, optional 6-position automated sample loader |
| Data Reproducibility | NIST SRM 660c LaB₆ reference standard, RSD ≤ 0.003% (peak position, 2θ) |
| Control Interface | External PC or integrated 10.1″ capacitive touchscreen |
| Dimensions (L×W×H) | 880 mm × 705 mm × 735 mm |
| Mass | ≤180 kg |
| Electrical Supply | AC 200–240 V, 50/60 Hz |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom-Engineered System |
| Pricing | Available Upon Request |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Product Category | Domestic (PRC-Made) |
| Model | Custom-Engineered X-Ray Instrument Systems |
| Pricing | Available Upon Technical Consultation |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | X-Ray Reflective Mirror |
| Pricing | Available Upon Request |
| Focal Length | 110 mm |
| Optimized Energies | 8.0 keV (Cu Kα), 17.24 keV (Mo Kα) |
| Output Beam Divergence | ΔΦ ≤ 0.4 mrad |
| Reflectivity | ≥ 65% (integrated, at optimized energy) |
| Dimensions (L × W × H) | 100 mm × 40 mm × 30 mm (custom sizes available) |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFocus |
| Pricing | Available Upon Request |
| Target Applications | XRD, XRF |
| Anode Materials | Mo, Cu, W, Ag, Cr, Co, Fe, Ti |
| Tube Voltage Range | 20–60 kV |
| Tube Current Range | 5–40 mA |
| Max Power Output | 0.4–3.0 kW (material-dependent) |
| Beam Geometry | Linear focal spot (line focus) |
| Protection Features | Overvoltage, Overcurrent, Overpower shutdown |
| Thermal Management | Adaptive preheat algorithm based on idle time |
| Brand | GKInst |
|---|---|
| Model | GK-GTS500/200/20 |
| Force Range | 0–500 N / 0–200 N / 0–20 N |
| Force Resolution | 0.01 N |
| Max. Extension | 80 mm |
| Displacement Resolution | 0.01 mm |
| Displacement Speed | 1–1000 µm/s |
| Force Control Modes | Constant Velocity, Constant Load, Position Hold, Jog, Cyclic Loading |
| Vacuum Compatibility | Customizable for Ultra-High Vacuum (≤10⁻⁵ Pa) |
| Brand | GKInst (Anhui GK Instrument Co., Ltd.) |
|---|---|
| Origin | Anhui, China |
| Model | AIR-SL-A30 / HV-SL-A30 / UHV-SL-A30 |
| Max Aperture | 30 mm × 30 mm |
| Resolution | 1 µm |
| Repeatability | 1 µm |
| Positioning Accuracy | ±2 µm |
| Blade Material | Tungsten Carbide (2 mm thick) |
| Housing Material | Anodized Aluminum (AIR/HV) / Stainless Steel (UHV) |
| Weight | 3.8 kg / 4.0 kg / 26 kg |
| Motor | Bipolar Stepper Motor |
| Vacuum Compatibility | Up to 10⁻⁵ mbar (AIR), 10⁻⁹ mbar (UHV), customizable to 10⁻⁶ mbar or lower |
| Flange Options | KF, CF (standard CF100), custom |
| Encoder Options | Absolute or Incremental (optional) |
| Customizable Aperture Shape | Rectangular, elliptical, or user-defined profiles |
| Optional Blade Materials | GaAs, Si, Cu, Ge |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Model | VGHS200 |
| Maximum Temperature | 200 °C |
| Minimum Temperature | Room Temperature (RT) |
| Max. Heating Rate | 30 °C/min |
| Temperature Stability | < 0.5 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Temperature Control | PID Dynamic Regulation |
| Application Domain | In-situ XRD for Materials Science, Semiconductor Characterization, Battery Research, Pharmaceutical Solid-State Analysis, and Mineralogical Studies |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | D-POWER |
| Price Range | USD 42,000 – 210,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-standing |
| Power Rating | 3 kW |
| Angular Accuracy | 0.0001° |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiniSAXS |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| Measurement Range | 1 nm – 100 nm |
| Available Anode Materials | Cu, Mo, Ag |
| Collimation | Pinhole-based collimation system |
| Filtration | Integrated beam filtration unit |
| Sample Stage | Motorized 3-axis stage with 16-position powder holder and 16-position solid-sample holder |
| Detector | Two-dimensional silicon pixel array single-photon counting detector |
| Pixel Size | 75 µm × 75 µm |
| Readout Mode | Continuous, zero dead time, no readout noise or dark current |
| Dynamic Range | 32-bit |
| Sample-to-Detector Distance (SD) | 40 mm – 350 mm |
| Scattering Vector (q) Range | 0.063 nm⁻¹ – 6.3 nm⁻¹ |
| Dimensions (W×D×H) | 840 mm × 750 mm × 700 mm |
| Power Supply | AC 220 V, 50 Hz (single-phase) |
| Supported Techniques | SAXS, WAXS, GIWAXS, GISAXS |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Customizable DAC |
| Pricing | Available Upon Request |
| Maximum Pressure | Up to 300 GPa (under proper operation and calibration) |
| Symmetric Configuration | Standard |
| High-Temperature Capability | Custom-integrated |
| Maximum Diffraction Angle | ≥50° |
| Alignment Precision | ≤3 µm |
| Interference Fringe Count (Post-Alignment) | ≤1.5 fringes |
| Dual-Function Compatibility | Simultaneous high-pressure and electrical transport measurements |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Model | EC150 |
| Temperature Range | −50 °C to +150 °C |
| Max. Heating/Cooling Rate | 30 °C/min |
| Temp. Stability | < 0.05 °C |
| Temp. Resolution | 0.01 °C |
| Sensor | PT100 Platinum Resistance Thermometer |
| Control Algorithm | PID Dynamic Regulation |
| Compliance | Designed for ASTM D3418, ISO 11357, and IEC 62660-2 thermal cycling protocols in electrochemical cell characterization |
| Brand | GKINST |
|---|---|
| Model | XMS-P15-AP-Ta5 |
| Aperture Diameter | 10 mm |
| X-ray Energy Range | 12–30 keV |
| Operating Temperature | 10–50 °C |
| Control Interface | 6-pin aviation connector |
| Drive Voltage/Current | ≤30 V, ≤2 A |
| Supply Voltage | 18 VDC |
| Dimensions (L×W×H) | 200 × 70 × 34 mm |
| Weight | 0.6 kg |
| Brand | GKINST |
|---|---|
| Model | GK-THMS350V |
| Max Temp | 350 °C |
| Min Temp | −195 °C |
| Max Heating Rate | 150 °C/min |
| Max Cooling Rate | 30 °C/min |
| Temp Resolution | < 0.05 °C |
| Temp Stability | < 0.05 °C |
| Control Algorithm | PID Dynamic Regulation |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Brand | GKinst |
|---|---|
| Model | GK-THMS600V |
| Temperature Range | −195 °C to +600 °C |
| Max. Heating Rate | 180 °C/min (customizable) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | <0.1 °C |
| Compatibility | Optical Microscopes, Raman Spectrometers, FTIR Microscopy Systems, UV-Vis Microspectrophotometers |
| Brand | GKinst |
|---|---|
| Model | GK-BSD Series |
| Material | Cu-Pb Composite |
| Diameter Range | 1.5–10 mm |
| Rod Diameter | 4 mm |
| Rod Length | 200 mm (customizable) |
| Compliance | ISO 17025-aligned installation practices |
| Mounting | Standard M4 threaded stem |
| Radiation Attenuation | Optimized for Cu Kα (8.04 keV) and Mo Kα (17.48 keV) X-ray sources |
| Brand | GKInst |
|---|---|
| Model | NFC |
| Type | Flow-through X-ray Transmission Cell |
| Window Material | Silicon Nitride (Si₃N₄) |
| Window Size | 1.5 mm × 1.5 mm |
| Window Thickness | 200 nm |
| Cell Volume | 5 mL |
| Cell Body Thickness | 1 mm |
| Fluidic Interface | M6 threaded port |
| Noise Suppression | Optimized laminar-flow pump coupling and acoustic decoupling mount |
| Brand | GKINST |
|---|---|
| Model | Customizable DAC Gas Loading System |
| Max Operating Pressure | 200 MPa |
| Compatible Gases | He, Ne, Ar, N₂, CH₄, H₂ (O₂ excluded) |
| DAC Compatibility | Modular Design for Standard & Custom DACs |
| Origin | Anhui, China |
| Supplier Type | Authorized Distributor |
| Brand | GKinst |
|---|---|
| Model | GK-TST350V |
| Force Range | 0–500 N / 0–200 N / 0–20 N |
| Force Resolution | 0.01 N |
| Max. Extension | 80 mm |
| Displacement Resolution | 0.01 mm |
| Displacement Speed | 1–1000 µm/s |
| Force Control Modes | Constant Velocity, Constant Force, Position Hold, Jog, Cyclic Loading |
| Vacuum Compatibility | Customizable for Ultra-High Vacuum (≤1×10⁻⁵ Pa) |
| Temperature Range | –195 °C to +350 °C |
| Origin | Anhui, China |
| Brand | GKinst |
|---|---|
| Model | GK-DLS-01 |
| Laser Wavelength | 633 ± 0.5 nm |
| Output Power | > 30 mW |
| Power Stability | < 0.5% |
| Spectral Linewidth | < 0.03 nm |
| Coherence Length | > 1 m |
| Detector Type | APD |
| Photosensitive Area | Φ0.5 mm |
| Spectral Response Range | 400–800 nm |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Molecular Weight Range | 10³–10⁸ g/mol |
| Hydrodynamic Diameter Range | 0.3 nm – 10 μm |
| Minimum Sample Volume | ≥ 0.5 μL |
| Origin | Anhui, China |
| Instrument Type | Benchtop DLS System |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Custom-Engineered DAC Dynamic Actuation System |
| Pricing | Available Upon Technical Inquiry |
| Brand | GKINST |
|---|---|
| Model | EC120 |
| Temperature Range | –50 °C to +120 °C |
| Max. Heating/Cooling Rate | 30 °C/min |
| Temp. Stability | < 0.05 °C |
| Temp. Resolution | 0.01 °C |
| Sensor | PT100 Platinum Resistance Thermometer |
| Control Algorithm | PID Dynamic Regulation |
| Compatibility | Liquid-phase electrochemical cells (e.g., coin-cell, pouch-cell, fuel cell configurations) |
| Compliance | Designed for integration with X-ray diffractometers (XRD), synchrotron beamlines, and in situ/operando electrochemical characterization platforms |
| Brand | GKInst |
|---|---|
| Model | LaScater 1.0 |
| Origin | Anhui, China |
| Instrument Type | Integrated SAS System |
| Laser Wavelength Range | 390–780 nm |
| Laser Power | 1–100 W (continuously adjustable) |
| Power Stability | < 1% RMS |
| Beam Divergence | < 0.015° |
| Sample Stage Travel (X/Y) | ±75 mm |
| Z-Travel | ±10 mm |
| Positioning Accuracy | 1 µm |
| Angular Axes (β/γ) | ±7.5°, Resolution: 0.001° |
| Rotational Axis (α) | 360°, Resolution: 0.001° |
| Detector | CCD/CMOS hybrid sensor |
| Pixel Size | 10 µm × 10 µm |
| SNR | >40 dB |
| Peak Quantum Efficiency | 0.65 A/W |
| Frame Rate (high-speed mode) | up to 60 fps |
| Cooling | Peltier-based thermoelectric cooling for low-noise acquisition |
Show next