| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Cuff Model | NO. 10 |
| Pricing | Available Upon Request |
| Animal Size Range | Canine, NHP, Feline, Rabbit, Guinea Pig |
| Measurement Method | Oscillometric (Air-Vibration) |
| Display | High-Contrast LCD with Real-Time Pulse Waveform Monitoring |
| Data Storage | Internal Memory ≥ 100 Sessions |
| Interface | RS-232/USB for PC Communication |
| Software Included | BPView™ Data Management Suite (Waveform Capture, Export, Audit Trail) |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM-6240BD / RM-6240CD |
| Interface | USB 2.0 |
| Max Sampling Rate | 1000 kHz (single channel) |
| Input Impedance | ≥100 MΩ (differential) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS |
| Frequency Response | DC–10 kHz |
| Input Range | 5 µV–500 mV |
| Sensitivity Ranges | Bioelectric: 20 µV/div–500 mV/div |
| Blood Pressure | 0.48–24 kPa/div or 3.6–180 mmHg/div |
| Hardware Filters | Low-pass: 3/10/30/100/500/1k/3k Hz, OFF |
| Time Constant | 0.001–5 s, DC |
| Stimulator Output | Voltage: 0–150 V (opt.), Current: 0–150 mA |
| Pulse Width/Delay/Interval | 0.1–1000 ms |
| Frequency | 1–3000 Hz |
| Calibrated Transducers | Tension: 0–50 g, Sensitivity: 100 mV/30 g (6 V DC) |
| Pressure | −10 to +40 kPa, Sensitivity: 25 mV/12 kPa (6 V DC) |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240E/EC |
| Channel Count | 4 (expandable to 8 or 16 via daisy-chaining) |
| A/D Resolution | 16-bit |
| Max Single-Channel Sampling Rate | 1,000 kHz |
| Min Sampling Rate | 0.01 Hz |
| Continuous 4-Channel Sampling Rate | 200 kHz |
| Input Impedance | ≥100 MΩ (differential), ≥50 MΩ (single-ended) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS / ≤±3 µV P-P |
| Frequency Response | DC–20 kHz |
| Input Range | 5 µV–500 mV |
| Gain Settings | 10 µV/div–500 mV/div (bioelectric), 0.36–360 mmHg/div (blood pressure) |
| Hardware Filters | Low-pass (0.3 Hz–20 kHz, OFF), Time Constant (0.001 s–DC), 5+ order analog filtering |
| Stimulator Output | ±50 V max, ≤100 mA, programmable pulse modes (single, train, dual, incremental, timed), galvanically isolated |
| ECG Lead Support | Full 12-lead (I, II, III, aVR, aVL, aVF, V1–V6), software-switchable |
| Environmental Sensors | Integrated temperature, atmospheric pressure, and humidity measurement |
| Software Certifications | Certified software copyright (No. 2012SR137470), Sichuan Software Registration Certificate (Chuan DGY-2013-0154) |
| Data Export | MATLAB (.mat), SPSS (.sav), SAS (.sas7bdat), CSV |
| Compliance | Meets national safety standards for biomedical instrumentation (leakage current <3 mA) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BP-2010A |
| Pricing | Available Upon Request |
| Display | 4.3-inch color LCD |
| Measurement Principle | Infrared photoplethysmography (PPG) |
| Method | Tail-cuff occlusion with automated inflation/deflation |
| Temperature Control Range | 30–40 °C (adjustable via host or software) |
| Blood Pressure Range | 0–350 mmHg |
| Pulse Rate Range | 0–1000 BPM |
| Measured Parameters | Systolic BP, Mean Arterial Pressure (MAP), Diastolic BP, Heart Rate |
| Data Storage | SD card and/or PC via USB 2.0 |
| Software Features | Automated measurement initiation, post-acquisition editing, averaging (6–7 cycles), scheduled measurements, report generation (PDF/CSV), GLP-compliant audit trail export |
| Throughput | Up to 3 rodents per session (sequential) |
| Measurement Duration | ≤15 min (rats), ≤5 min (mice) |
| Compliance | Designed for ISO 13485-aligned manufacturing environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MRBP-R01 |
| Pricing | Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DSWY-1 |
| Pricing | Available Upon Request |
| Sensor Included | Yes |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FOP-LS-PT9-10 |
| Pressure Range | ±300 mmHg |
| Accuracy | ±3 mmHg |
| Resolution | ±0.3 mmHg (dependent on filter settings) |
| Operating Temperature | 10–50 °C |
| Sampling Rate | Analog Output: 15,000 Hz |
| Digital Output | 5,000 Hz (configurable via Evolution software) |
| Data Output | USB 2.0 (digital, 16-bit) / 0–5 V analog |
| Catheter Size | 0.5 Fr (FOP-LS-PT9-11), 0.9 Fr (FOP-LS-PT9-10), 2 Fr (FOP-LS-2FR-10), 3 Fr (FOP-LS-3FR-10) |
| MRI Compatibility | Yes (RF- and EMI-immune) |
| Sensor Type | Non-electronic fiber-optic transducer |
| Reusability | Multiple-use catheter |
| Signal Conditioning | FPI-LS-10 single-channel optical signal conditioner |
| Data Acquisition | Compatible with iWorx IX-4041 4-channel system & LabScribe2 software |
| Optional Module | LS-30BP blood pressure analysis add-on |
| Brand | YUYANBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | YUYANBIO Instrument Co., Ltd. |
| Model | NIBP-M1 (Single-Channel) / NIBP-MR4 (4-Channel) |
| Measurement Principle | Oscillometric + Infrared Photoplethysmography |
| Temperature-Controlled Warming Platform | Yes |
| Output Parameters | Systolic BP (SBP), Diastolic BP (DBP), Mean Arterial Pressure (MAP), Heart Rate (HR) |
| Data Export Format | Raw binary + CSV/Excel |
| Software Compliance | Audit trail-capable data logging, timestamped acquisition, user-access control |
| Channel Capacity | 1–4 simultaneous rodents (mouse or rat) |
| Animal Compatibility | Mouse (20–35 g) and Rat (200–500 g) with interchangeable tail-cuff adapters |
| Regulatory Context | Designed for preclinical GLP-compliant cardiovascular phenotyping |