Animal Experiment Instruments
Filter
Showing 1–30 of 95 results
| Brand | Allentown |
|---|---|
| Origin | USA |
| Model | BCU-2 |
| Cage Capacity | 48 (6 × 8) |
| Frame Material | 304 Stainless Steel |
| Cage Material | Polysulfone (PSU) |
| HEPA Class | H14 (Filtration Efficiency ≥99.995% @ 0.1 µm) |
| Operating Pressure | Stable Negative Pressure (Controlled via Feedback Loop) |
| Sterilization | Autoclavable at 134°C |
| Backup Power | ≥10 h (at 50% airflow) |
| Dimensions (W×D×H) | 1466 × 651 × 1995 mm (incl. casters) |
| Weight | 148 kg (empty), 237 kg (fully loaded) |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Discovery™ IVC |
| Regulatory Classification | Imported Medical/Research Equipment |
| Distribution Model | Authorized Distributor |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | EasyCage |
| Cage Base Area (Mouse) | 500 cm² |
| Cage Base Area (Rat) | 903 cm² |
| Feed Capacity (Mouse) | 454 g (HDPE hopper) |
| Feed Capacity (Rat) | 798 g (stainless steel wire mesh lid) |
| Water Options | 300 mL bottle (mouse), dual 300 mL bottles or automatic water (rat) |
| Material | BPA-free, recyclable PET |
| Compatibility | NexGen IVC rack platform |
| Airflow Control | Positive/negative pressure configurable |
| Structural Frame | 304 stainless steel, autoclavable at 134°C |
| Integrated Bedding | NestPak® (100 g pre-filled with ALPHA-dri®, corn cob, or Performance BioFresh™) |
| Ergonomic Features | Snap-fit assembly, visual docking indicators, lightweight design |
| Brand | Allentown |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ferret Isolator System |
| Pricing | Available Upon Request |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | NexGen |
| Construction | 304 Stainless Steel Frame |
| Sterilization Compatibility | Autoclavable at 134°C |
| Cage Material | Polysulfone (High-Transparency, USP Class VI Compliant) |
| System Integration | EcoFlo™ Blower, WiVarium Plus™ Wireless Monitoring, Sentinel™ Health Surveillance, Wi-Com Sensus™ RFID Tracking |
| Compliance | CCAC, AAALAC, NIH Guide, EU Directive 2010/63/EU |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Sentry SPP |
| Construction | 304 Stainless Steel Frame |
| Filtration | Dual Certified HEPA (Supply & Exhaust, Optional) |
| Sterilization | Autoclavable at 134°C |
| Power Backup | ≥10-hour Battery Redundancy |
| Cage Sizes | Mouse (537 cm² floor area), Rat (916 cm² floor area) |
| Sealing System | Patented 4-Point Automatic Seal (US Patent 6,308,660) |
| Docking Interface | SmartDock® Visual Alignment System |
| Compliance | Meets NIH Guide, AAALAC International standards, supports GLP/GMP-aligned animal facility operations |
| Brand | Alzet |
|---|---|
| Origin | USA |
| Type | Implantable Osmotic Delivery Device |
| Dimensions | ~19.7 mm × 5.6 mm (cylindrical capsule) |
| Delivery Duration | Up to 28 days (model-dependent) |
| Flow Rate Range | 0.11–10.0 µL/h (varies by model) |
| Reservoir Volume | 100–200 µL (model-dependent) |
| Material Compliance | USP Class VI-certified ethylene-vinyl acetate (EVA) and polyurethane |
| Sterilization | Ethylene oxide (EtO) |
| Biocompatibility | ISO 10993-1 tested |
| Operating Temperature | 37 °C (in vivo) |
| Accuracy | ±10% over specified duration |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | SmallFocus |
| Pricing | Available Upon Request |
| Tube Voltage Range | 20–90 kV |
| Focal Spot Size | 5 µm |
| Active Imaging Area | 325 mm × 325 mm |
| Flat-Panel Detector Resolution | 100 µm |
| Chamber Material | Stainless Steel |
| Exposure Control | Fully Automated One-Touch Exposure |
| Remote Diagnostics | Integrated Ethernet-Based Support |
| Image Processing | Dedicated Workstation Included |
| Brand | Smith |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APEX |
| Price | $1 (Reference Only) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 10–90% RH |
| Altitude Range | −400 to 3000 m |
| Dimensions (H×L×W) | 30.5 × 52 × 44.5 cm |
| Weight | 24 kg |
| Output Power | 7200 W continuous, 24,000 W peak |
| Output Voltage | 0–1200 VDC / 0–240 VRMS AC |
| Frequency Range | 1–1000 Hz |
| Waveforms | DC, Pulsed DC, Burst DC, AC |
| Onboard Data Logging | Peak/Avg Voltage, Current, Power, Waveform Parameters, GPS Coordinates, Timestamp, Internal Temperature, Altitude, Error Codes |
| Display | Sunlight-readable color LCD |
| Safety | Footswitch + Emergency Stop |
| Memory | 12 Predefined Waveform Profiles |
| Environmental Rating | IP54-equivalent enclosure for field use |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | CM-191 |
| Measurement Principle | Antimony Electrode Potentiometry (pH 4.00–9.00) & Glass Electrode Potentiometry (pH 0.00–14.00) |
| Temperature Compensation | Automatic/Manual (0°C to 100°C) |
| Input Impedance | >10¹³ Ω |
| Resolution | 0.01 pH / 1 mV |
| Accuracy (pH) | ±0.01 pH |
| Accuracy (mV) | ±1 mV |
| Display | Digital LCD |
| Power Supply | AC 100 V, 50/60 Hz (12 V DC adapter) |
| Power Consumption | ~1 VA |
| Dimensions (W×D×H) | 165 × 180 × 70 mm |
| Weight | ~1000 g |
| Data Output | 0–1.4 V analog signal (compatible with external data loggers) |
| Standard Accessories | pH 4.01 & 6.86 calibration buffers (1× each), 12 V AC adapter, 0–100°C thermometer |
| Optional Electrodes | CMS-191 antimony micro-catheter electrode (1.0 mm OD), CM-181 glass electrode (2.4 mm OD) |
| Brand | Asylum Research |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Rodent Metabolic Monitoring System |
| Model | Mice Metabolic Cage |
| Dimensions (L×W×H) | 210 × 210 × 400 mm |
| Material | Polycarbonate (PC), autoclavable at 120°C |
| Urine Collection Capacity | 15 mL |
| Water Bottle Capacity | 880 mL |
| Grid Aperture | Ø1 mm |
| Compliance | ISO 9001-certified manufacturing process |
| Sterilization | Compatible with steam autoclaving (120°C, 20 min) |
| Brand | Asylum Research |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Laboratory Animal Housing |
| Model | G-12 |
| Unit Price | USD 1,280 |
| Cage Layout | 3 columns × 4 rows = 12 individual units |
| Single Cage Dimensions | 500 × 400 × 260 mm (L×W×H) |
| Full Rack Dimensions | 2000 × 650 × 1720 mm (L×W×H) |
| Material | AISI 304 stainless steel |
| Components Included | Feed hopper, gravity-fed water bottle with stainless steel sipper tube, removable waste tray, integrated water reservoir |
| Compliance | Designed to meet NIH Guide for the Care and Use of Laboratory Animals, AAALAC International housing standards, and ISO 55000-aligned facility maintenance protocols |
| Brand | Aurora |
|---|---|
| Origin | USA |
| Model | 1300A |
| Force Range | Up to 10 N |
| Temperature Control | Precision-regulated platform |
| Stimulation | Biphasic current/voltage neuromuscular stimulator (701C) |
| Software | Dynamic Muscle Control & Analysis (DMC/DMA) |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, supports GLP-compliant audit trails and FDA 21 CFR Part 11–ready data export |
| Brand | Aurora Scientific |
|---|---|
| Origin | USA |
| Model | A1300 |
| Application Scope | Rodent (mouse/rat) skeletal muscle functional assessment |
| Core Sensor | Dual-Mode Muscle Lever (force + length transduction & actuation) |
| Temperature Control | Integrated thermostatic platform (±0.1 °C stability) |
| Stimulator | High-energy biphasic stimulator (0–200 V, 0.01–100 ms pulse width) |
| Data Acquisition | Up to 100 kHz sampling rate |
| Software Platform | DMC/DMA v6.x (Windows/Linux compatible) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Avisoft |
|---|---|
| Origin | Germany |
| Model | UltraSoundGate 116Hm |
| Channel Count | Dual-channel (stereo) |
| Sampling Rate | Up to 384 kHz |
| Bit Depth | 24-bit |
| Frequency Range | 0.5 Hz – 250 kHz (ultrasonic-capable) |
| Input Impedance | >10 MΩ |
| Preamp Gain | Adjustable up to +60 dB |
| Power Supply | USB bus-powered or external 5 V DC |
| Environmental Rating | IP54 (dust- and splash-resistant) |
| Software | Avisoft-SASLab Pro v5.2+ |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & electronic signature support via optional configuration) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Cuff Model | NO. 10 |
| Pricing | Available Upon Request |
| Animal Size Range | Canine, NHP, Feline, Rabbit, Guinea Pig |
| Measurement Method | Oscillometric (Air-Vibration) |
| Display | High-Contrast LCD with Real-Time Pulse Waveform Monitoring |
| Data Storage | Internal Memory ≥ 100 Sessions |
| Interface | RS-232/USB for PC Communication |
| Software Included | BPView™ Data Management Suite (Waveform Capture, Export, Audit Trail) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF50 / LF90 |
| Application | In vivo quantitative analysis of fat mass, lean body mass, and free fluid in live mice and rats |
| Measurement Principle | Pulsed low-field TD-NMR (1H) at 0.047 T (2 MHz) |
| Sample Orientation | Vertical or horizontal magnet configuration |
| Analysis Time | ≤ 120 s per animal |
| Animal Safety | Non-invasive, no ionizing radiation, no anesthesia required |
| Regulatory Context | Compliant with GLP-aligned data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF50/mq7.5 |
| Measurement Principle | Time-Domain Nuclear Magnetic Resonance (TD-NMR) |
| Operating Frequency | 7.5 MHz |
| Maximum Sample Mass | 85 g (mice) |
| Sample Tube Inner Diameter | 49 mm |
| System Footprint | ~70 cm × 110 cm |
| Regulatory Compliance | CE Marked, ISO 9001:2000 Certified |
| Software Platform | Microsoft Windows with Microsoft Access Database |
| Data Acquisition Interface | Graphical User Interface (GUI) optimized for lab operation |
| Calibration | User-performed with reference standards or biological samples |
| Animal State During Measurement | Conscious, non-anesthetized, unrestrained |
| Measurement Duration | Typically < 3 minutes per animal |
| Environmental Suitability | Designed for rodent housing facility integration (dust-resistant enclosure, shielded magnet housing) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF90II |
| Instrument Type | In Vivo Rodent (Mouse/Rat) Body Composition Analyzer |
| Operating Frequency | 6.2 MHz |
| Measurement Time | < 120 s per animal |
| Sample Handling | Non-invasive, anesthesia-free, restraint-only in dedicated cylindrical holder |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DHX |
| Pricing | Upon Request |
| Tidal Volume Range | 1–50 mL / 1–150 mL / 1–300 mL / 1–500 mL (selectable) |
| Respiratory Rate | 1–199 breaths/min |
| I | E Ratio Options: 1:1, 1:2, 1:3, 2:1 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 400 × 140 × 280 mm |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CQY-1 |
| Pricing | Available Upon Request |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM-6240BD / RM-6240CD |
| Interface | USB 2.0 |
| Max Sampling Rate | 1000 kHz (single channel) |
| Input Impedance | ≥100 MΩ (differential) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS |
| Frequency Response | DC–10 kHz |
| Input Range | 5 µV–500 mV |
| Sensitivity Ranges | Bioelectric: 20 µV/div–500 mV/div |
| Blood Pressure | 0.48–24 kPa/div or 3.6–180 mmHg/div |
| Hardware Filters | Low-pass: 3/10/30/100/500/1k/3k Hz, OFF |
| Time Constant | 0.001–5 s, DC |
| Stimulator Output | Voltage: 0–150 V (opt.), Current: 0–150 mA |
| Pulse Width/Delay/Interval | 0.1–1000 ms |
| Frequency | 1–3000 Hz |
| Calibrated Transducers | Tension: 0–50 g, Sensitivity: 100 mV/30 g (6 V DC) |
| Pressure | −10 to +40 kPa, Sensitivity: 25 mV/12 kPa (6 V DC) |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240E/EC |
| Channel Count | 4 (expandable to 8 or 16 via daisy-chaining) |
| A/D Resolution | 16-bit |
| Max Single-Channel Sampling Rate | 1,000 kHz |
| Min Sampling Rate | 0.01 Hz |
| Continuous 4-Channel Sampling Rate | 200 kHz |
| Input Impedance | ≥100 MΩ (differential), ≥50 MΩ (single-ended) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS / ≤±3 µV P-P |
| Frequency Response | DC–20 kHz |
| Input Range | 5 µV–500 mV |
| Gain Settings | 10 µV/div–500 mV/div (bioelectric), 0.36–360 mmHg/div (blood pressure) |
| Hardware Filters | Low-pass (0.3 Hz–20 kHz, OFF), Time Constant (0.001 s–DC), 5+ order analog filtering |
| Stimulator Output | ±50 V max, ≤100 mA, programmable pulse modes (single, train, dual, incremental, timed), galvanically isolated |
| ECG Lead Support | Full 12-lead (I, II, III, aVR, aVL, aVF, V1–V6), software-switchable |
| Environmental Sensors | Integrated temperature, atmospheric pressure, and humidity measurement |
| Software Certifications | Certified software copyright (No. 2012SR137470), Sichuan Software Registration Certificate (Chuan DGY-2013-0154) |
| Data Export | MATLAB (.mat), SPSS (.sav), SAS (.sas7bdat), CSV |
| Compliance | Meets national safety standards for biomedical instrumentation (leakage current <3 mA) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | C76688 |
| Pricing | Available Upon Request |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | AASS |
| Sound Output Range | 20 Hz – 25.5 kHz (audio), 20 Hz – 20 kHz (white noise) |
| Max SPL | 128 dB |
| Stimulus Control | Computer-controlled amplitude, frequency, duration, rise/fall time |
| Optional Modules | Footshock (up to 3.0 mA), Visual Flash Stimulus |
| Chamber Configuration | Single or 8-chamber sound-attenuated enclosures |
| Data Acquisition | Analog signal conditioning (amplification + integration), 16-bit ADC |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | Databiosci |
|---|---|
| Origin | Tianjin, China |
| Model | ASG-C |
| Compliance | ISO 3308:2012, CIR |
| Automation Level | Semi-Automatic |
| Ignition Type | Flameless (2 s) |
| Dilution Flow Rate | Up to 10 L/min |
| Dilution Ratio | 3–50% |
| Puff Volume Range | 3–150 mL |
| Puff Interval | ≥4.2 s/puff |
| Sample Capacity | 2 cigarettes (standard) |
| Material | Corrosion-Resistant Pathways (e.g., electropolished stainless steel, PTFE-lined) |
| Software | ecSoft v3.x (standalone or integrated with eComa platform) |
| Regulatory Conformance | FDA 21 CFR Part 11 (audit trail, electronic signature, user access control) |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HT-Respiro 24/96/240 Series |
| Pricing | Available Upon Request |
| Oxygen Measurement Range | 0–50% O₂ or 0–22.5 mg/L |
| Detection Limit | 0.15% O₂ (15 ppb DO) |
| Accuracy | ±1% at 20.9% O₂ |
| Resolution | ±0.4% at 20.9% O₂ or ±5 µmol at 283.1 µmol |
| Response Time | <30 s |
| Drift | <1% air saturation per week (10-min sampling interval) |
| Channel Capacity | Up to 240 parallel channels (10 × 24-channel readers) |
| Sensor Technology | Fluorescence-based optical oxygen sensing (REDFLASH for 96-well format) |
| Sample Chamber Material | Borosilicate glass (24-well) or sterile polystyrene (96-well) |
| Chamber Volume | 80–1700 µL (24-well) |
| Dimensions (per 24-channel reader) | 163 × 89 × 22 mm |
| Weight (per reader) | 380 g |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BP-2010A |
| Pricing | Available Upon Request |
| Display | 4.3-inch color LCD |
| Measurement Principle | Infrared photoplethysmography (PPG) |
| Method | Tail-cuff occlusion with automated inflation/deflation |
| Temperature Control Range | 30–40 °C (adjustable via host or software) |
| Blood Pressure Range | 0–350 mmHg |
| Pulse Rate Range | 0–1000 BPM |
| Measured Parameters | Systolic BP, Mean Arterial Pressure (MAP), Diastolic BP, Heart Rate |
| Data Storage | SD card and/or PC via USB 2.0 |
| Software Features | Automated measurement initiation, post-acquisition editing, averaging (6–7 cycles), scheduled measurements, report generation (PDF/CSV), GLP-compliant audit trail export |
| Throughput | Up to 3 rodents per session (sequential) |
| Measurement Duration | ≤15 min (rats), ≤5 min (mice) |
| Compliance | Designed for ISO 13485-aligned manufacturing environments |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Human Energy Metabolism Laboratory System |
| Price Range | USD 28,000 – 70,000 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |