Animal Experiment Instruments
Filter
Showing 31–60 of 95 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM-KC |
| CO₂ Analysis Principle | Dual-Wavelength NDIR |
| CO₂ Range | 0–5% |
| CO₂ Resolution | ≤0.1 ppm |
| CO₂ Accuracy | ±1% FS |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.0001% |
| O₂ Accuracy | ±0.1% FS |
| Flow Control Range | 5–1000 mL/min |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ±2% |
| Response Time (CO₂) | <1 s |
| 24-h Drift (CO₂) | <0.02% FS |
| Sample Compatibility | Drosophila, Aphids, Nematodes, Spiders, Lepidopteran Larvae/Pupae, Bees, Grasshoppers, Soil Invertebrates |
| Brand | Histrong |
|---|---|
| Model | HC-800 |
| Measurement Range | 0–190 mg/L and 0–12,000 mg/L |
| Sample Types | Urine, Serum, Saliva, Aqueous Solutions |
| Resolution | 0.01 mg/L |
| Analysis Time | <3 min per sample |
| Display | Dual-output (LCD + Thermal Printer) |
| Communication Interfaces | RS232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50 Hz, <60 W |
| Dimensions | 38.5 × 23.5 × 34.5 cm |
| Operating Environment | 10–35 °C, RH <85%, Low Magnetic Interference |
| Compliance | Designed for GLP-compliant laboratory workflows |
| Software Option | Optional LIMS-integrated data management module |
| Brand | Hope-Med |
|---|---|
| Origin | Tianjin, China |
| Model | 8052DS |
| Chamber Operating Pressure Range | −20 Pa to 0 Pa (gauge, negative pressure mode) |
| Animal Capacity | Up to 25 kg (e.g., Beagle dogs) |
| Number of Exposure Ports | ≥4 |
| Aerosol Concentration Capability | ≥10,000 mg/m³ (liquid/solid aerosols) |
| Inter-port Uniformity | ±10% for gas & liquid aerosols |
| Construction | Stainless steel main frame with chemically resistant soft-contact interior surfaces |
| Fault Monitoring | Real-time alerts for condensate accumulation, electrical faults, pressure, temperature, relative humidity, O₂, and CO₂ deviations |
| Compliance | Designed to support OECD 412, ASTM E171, ISO 10993-12, and GLP-aligned inhalation toxicology workflows |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HSS-1B |
| Quotation | Upon Request |
| Temperature Control Range | Room Temp +10°C to 100°C |
| Temperature Stability | ±0.03°C |
| Heating Power | 1 kW |
| Circulation Pump Flow Rate | 6 L/min |
| Bath Tank Dimensions (L×W×H) | 330 × 200 × 180 mm |
| Bath Opening Dimensions | 190 × 160 mm |
| External Dimensions | 385 × 250 × 380 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Bath Tank Material | Stainless Steel (304) |
| Bath Volume | 12 L |
| Analgesia Chamber Diameter | φ160 mm |
| Brand | IITC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 600M (Mouse) / 600R (Rat) Dual-Paw Weight-Bearing Nociception Analyzer |
| Dimensions (H×W×D) | 31 cm × 30 cm × 25 cm |
| Weight | 2.6 kg (instrument only, excluding pedals, restraint, and power cord) |
| Max Load per Paw | 2200 g |
| Resolution | 0.05 g (<500 g), 0.1 g (full scale) |
| Accuracy | ±0.5% FS |
| Data Output Format | .csv (Excel-compatible) |
| Internal Storage | 4 GB (≥10,000 assays) |
| Measurement Duration | 1–360 s |
| Trigger Mode | Manual or Auto-Start (Ugo Basile–inspired activation logic) |
| Power Supply | 90–260 VAC, fanless design |
| Compliance | GLP-compliant data logging architecture, audit-ready metadata tagging |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 390 or 390G (Capacity: 6 Rats or 12 Mice) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MRBP-R01 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JTC-1 |
| Pricing | Upon Request |
| Output Voltage Range | 0–120 V AC (50 Hz), Continuously Adjustable |
| Output Current | ≥100 mA |
| Stimulation Modes | Single Pulse, Continuous Train, Externally Triggered Programmable Mode |
| Stimulation Duration | 0.2, 0.3, 0.4, 0.5, 0.6 s |
| Inter-Stimulus Interval (ISI) | Single Pulse, 1, 2, 5, 10 s |
| Trigger Sources | Internal Clock or External TTL-Compatible Signal (5–15 V) |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Classification | Domestic (China) |
| Model | S12033-11 |
| Pricing | Upon Request |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LE509 |
| Pricing | Available Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MDS-1 |
| Pricing | Upon Request |
| Brand | Melton Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | INHALOGIC MIES-N |
| Pricing | Upon Request |
| Brand | Melton Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | INHALOGIC NIES-GLP |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MGS-1/4 |
| Price | Upon Request |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | Vetus 9 |
| Imaging Platform | ZST+ Zone Scanning Technology |
| Core Modalities | B-mode, Color/Power Doppler, Pulsed-wave & Continuous-wave Spectral Doppler, Contrast-enhanced Ultrasound (UWN+), Shear Wave Elastography, Tissue Doppler Imaging (TDI), Tissue Tracking Quantification |
| Regulatory Status | CE Marked, FDA 510(k) cleared for veterinary use |
| Intended Use | Diagnostic imaging and functional assessment in companion animals, equine, and large animal clinical practice |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MSZ-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MTS-1 |
| Pricing | Upon Request |
| Brand | Muromachi |
|---|---|
| Origin | Imported (Japan) |
| Model | 51730M |
| Drive Type | Motorized (Stepper Motor Actuation) |
| Axes | X (Mediolateral), Y (Anteroposterior), Z (Dorsoventral) |
| Position Resolution | 10 µm per step |
| Control Interface | Capacitive Touchscreen Display |
| Manual Override | Integrated Mechanical Knobs |
| Joystick Mode | Analog Force-Feedback Translation |
| Zero-Point Memory | One-Touch Reference Reset |
| Compliance | ASTM F2118-22 (Stereotaxic Device Performance Criteria), ISO 13485–Certified Manufacturing Environment |
| Brand | Muromachi |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | MK-AL21D |
| Oxygen Flow Rate | 0.5–5 L/min |
| Vaporizer Capacity | 250 mL (max) |
| Adjustable Anesthetic Concentration Range | 0–5% (v/v) |
| Delivery Format | Benchtop, Key-Operated Fill System |
| Safety Compliance | Non-flammable anesthetic compatible (e.g., isoflurane, sevoflurane) |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MYS-1 |
| Pricing | Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DSWY-1 |
| Pricing | Available Upon Request |
| Sensor Included | Yes |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE8815 / LE8816 |
| External Dimensions | 450 × 450 × 200 mm or 220 × 220 × 200 mm |
| Infrared Frame Options | 450 × 450 mm (32 sensors, 25 mm spacing) or 250 × 250 mm (32 sensors, 13 mm spacing) |
| IR Wavelength | 950 nm |
| Sampling Frequency | 40 Hz |
| Software | Acti-Track v5.x |
| Max Concurrent Channels | 32 |
| Configurable Zones | Single-animal or dual-animal (split-zone) mode |
| Behavioral Metrics | Distance traveled, velocity profiles (max/min/mean), time-in-zone, zone entries, rearing count & duration, rotation counts, trajectory-based path analysis, nose-poke detection (threshold-defined), ambulation classification (fast/slow/immobility) |
| Brand | Parvo Medics |
|---|---|
| Origin | USA |
| Model | True One2400 |
| O₂ Analysis Range | 0–100% or 0–25% |
| O₂ Accuracy | ±0.02% |
| O₂ Response Time | 200 ms (21% → 16% in 4 L mixing chamber) |
| CO₂ Analysis Method | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–15% |
| CO₂ Accuracy | ±0.03% (for 0–10% CO₂) |
| CO₂ Response Time | 100 ms |
| Flow Measurement Accuracy | ±0.5% |
| Flow Range | 0–800 L/min |
| Calibration | Dual-stage (3 L syringe, 16% O₂ / 4% CO₂ gas mixture) |
| Operating Temperature | 14–30 °C |
| Relative Humidity | 20–80% RH |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Software Platform | Windows XP–compatible proprietary metabolic analysis suite |
| Data Export | Native Excel (.xls) output |
| Brand | SCChengyi |
|---|---|
| Model | PHG-1 |
| Temperature Range | Ambient to 100°C |
| Max Heating Power | 350 W |
| Heating Time (Ambient → 38°C) | <10 min |
| Operating Voltage | AC 220 V, 50 Hz |
| Temperature Control Accuracy | ≤0.2°C |
| Display Resolution | 0.1°C |
| Dual Display | Actual & Set Temperature |
| Dual Preheating Reservoirs | 45 mL and 200 mL |
| Preheating Glass Tubes | Three 20 mL + One 60 mL Quartz Tubes |
| Leakage Protection | 10 mA Trip Current |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 68016 |
| Price Range | USD 1,400 – 7,000 |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | 68306 |
| Pricing | Available Upon Request |
| Scale Resolution | 1 mm |
| Tip Geometry | 60° Blunt Angle |
| Design Purpose | Minimized Cranial Pressure for Mouse Skull Integrity |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 68511 |
| Pricing | Available Upon Request |
| Precision Options | 100 µm / 10 µm |
| Configuration | Lightweight, Single-Arm, Digital Readout, Rat-Specific |
| Structural Design | Open-Frame Architecture (No U-Shaped Frame) |
| Compatibility | Standard Rodent Ear Bars, Nose Clips, Microinjection Pumps, Manual/Electric Cranial Drills, Inhalational Anesthesia Systems (e.g., RWD Anesthesia Units) |
| Mounting Flexibility | Benchtop or Custom Rig Integration |