| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DHX |
| Pricing | Upon Request |
| Tidal Volume Range | 1–50 mL / 1–150 mL / 1–300 mL / 1–500 mL (selectable) |
| Respiratory Rate | 1–199 breaths/min |
| I | E Ratio Options: 1:1, 1:2, 1:3, 2:1 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 400 × 140 × 280 mm |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM-KC |
| CO₂ Analysis Principle | Dual-Wavelength NDIR |
| CO₂ Range | 0–5% |
| CO₂ Resolution | ≤0.1 ppm |
| CO₂ Accuracy | ±1% FS |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.0001% |
| O₂ Accuracy | ±0.1% FS |
| Flow Control Range | 5–1000 mL/min |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ±2% |
| Response Time (CO₂) | <1 s |
| 24-h Drift (CO₂) | <0.02% FS |
| Sample Compatibility | Drosophila, Aphids, Nematodes, Spiders, Lepidopteran Larvae/Pupae, Bees, Grasshoppers, Soil Invertebrates |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | VentStar |
| Pricing | Upon Request |
| Brand | Unisense |
|---|---|
| Origin | Denmark |
| Model | microrespiration |
| Detection Principle | Amperometric Microsensor-Based Closed-Circuit Respirometry |
| Measurement Range (O₂) | 0–500 µM |
| Current Resolution | 10⁻¹² A |
| Detection Limits | O₂: 0.3 µM |
| NO | 20–30 nM |
| Sample Volume Capacity | 0.5–8 mL (dual-port microrespiration vials) |
| Electrode Compatibility | O₂, H₂, H₂S, NO, N₂O, pH, Redox, Temperature, Flow, Diffusivity, NO₂⁻, NO₃⁻ |
| Signal Processing | Low-Noise Analog Amplification + 24-bit ADC Conversion |
| Compliance | GLP-Compatible Data Acquisition Architecture |
| Brand | YUYANBIO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | V-100 |
| Price Range | USD 1,400 – 7,000 |
| Power Supply | 220 V AC |
| Dimensions | 24 × 16 × 10 cm |
| Weight | 1.5 kg |
| Operating Temperature | −10 °C to 60 °C |
| Relative Humidity | 20–80 % RH |
| Respiratory Rate | 1–300 breaths/min |
| Tidal Volume | 0.1–10 mL (0.1 mL step resolution) |
| I | E Ratio: 1:5 to 5:1 (0.1 step) |
| Peak Inspiratory Pressure Limit | 6 kPa |
| Airway Pressure Relief | Automatic overpressure release with user-set threshold |
| Gas Source | Ambient air or external gas supply (no high-pressure gas required) |
| Drive Mechanism | Electrically driven, electronically controlled |
| Interface | Touch-sensitive digital control panel with LED indicators (inspiration/expiration/maintained inspiration) |
| Safety Features | Real-time pressure monitoring, audible/visual alarms, fail-safe pressure limiting |