| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3350 cm⁻¹ |
| Spectral Resolution | 4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| [Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AT-X100 |
| Portability | Handheld / Field-Deployable |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% (w/w) |
| Repeatability | ≤ 0.1% RSD |
| Detector Options | Si-Pin or SDD (Selectable) |
| Compliance | Designed for field-deployable environmental screening per EPA Method 6200, ASTM D7298, and China’s HJ 1003–2018] |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AT-Z300 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Ultraviolet Spectrophotometry (UV-Vis) |
| Measurement Range | 0.002–64,000 mg/L |
| Limit of Detection (LOD) | < 0.01 mg/L |
| Accuracy | ±0.2 mg/L |
| Resolution | < 0.004 mg/L |
| Analysis Time per Sample | 7–12 minutes |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Principle | Infrared Spectrophotometry (Fourier-transform-free, Dispersive NIR with Fixed-Wavelength Detection at 2930, 2960, and 3030 cm⁻¹) |
| Measurement Range | 0.002–64,000 mg/L |
| Detection Limit | < 0.04 mg/L |
| Accuracy | ±2% (relative error, certified reference materials) |
| Resolution | 0.002 mg/L |
| Analysis Cycle Time | 30 seconds per sample (including extraction solvent introduction, cell filling, and spectral acquisition) |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Model | AT-RS200 |
| Spectral Range | 200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis) |
| Spectral Resolution | ≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Detection Modalities | Surface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA) |
| Total Assay Coverage | ~600 analytes across food safety, environmental monitoring, and veterinary medicine |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HART375 |
| Instrument Type | HART Protocol Field Communicator |
| Calibration Target | HART-enabled Pressure Transmitters, Temperature Transmitters, Flow Meters |
| Design | Integrated Handheld Unit |
| Application Environment | Industrial Plant Floors, Control Rooms, Field Maintenance Zones |
| Communication Modes | Point-to-Point, Multi-Drop (4–20 mA Loop), HART Primary Master Emulation |
| Supported Devices | All HART Revision 5–7 compliant field instruments |
| Power Source | Internal Rechargeable Li-ion Battery (Typical Runtime: >12 h continuous operation) |
| Loop Interface | Built-in 250 Ω precision resistor, loop-powered operation |
| Display | 3.5" TFT LCD (320 × 240 pixels), sunlight-readable with adjustable backlight |
| Environmental Rating | IP65 (Dust-tight, water-jet resistant) |
| Operating Temperature | –10 °C to +50 °C |
| Compliance | IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Immunity), ATEX/IECEx Zone 2 / Class I Div 2 (Optional Certified Variant Available) |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AT-H300 |
| Instrument Type | Laboratory |
| Measurement Principle | Infrared Spectrophotometry (Fourier-transform-free, dual-beam fixed-wavelength absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹) |
| Measurement Range | 0.01–64,000 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±0.01 mg/L |
| Resolution | 0.004 mg/L |
| Sample Throughput | 7–10 minutes per sample |
| Compliance | HJ 637–2018, HJ 1051–2019, HJ 1077–2019, JJG 1153–2023 |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AT-AE06 |
| Price Range | USD 1,400 – 4,200 |
| Extraction Efficiency | 0–100% |
| Extraction Time | 0–999 s |
| Oscillation Method | Sealed, Clean Air Internal Circulation Agitation |
| Simultaneous Extraction Positions | 6 |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AT-AE06-Z |
| Extraction Efficiency | 0–99% |
| Extraction Time | 0–999 s |
| Agitation Method | Closed-loop Clean Air Oscillation |
| Simultaneous Extraction Capacity | 6 positions |
| Reagent Dispensing Range | 0–50 mL |
| Dispensing Accuracy | ≥2% |
| Sample Vessel Options | 250 / 500 / 1000 / 2000 mL (standard: 1000 mL) |
| Power Rating | 400 W |
| Voltage | 220 V ± 10% |
| Control Interface | 7-inch Color TFT Touchscreen |
| Waste Handling | Integrated Activated Carbon Filtration for Liquid & Gaseous Effluents |
| Cleaning Mode | Wide-angle Pressurized Spray Rinse |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AT-DX100 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–70 °C |
| Reagent Storage & Usage Temperature | 0–55 °C |
| Coefficient of Variation (CV) | ≤5% |
| Batch Capacity | 1–10 samples per run |
| Detection Time | ≤5 minutes |
| Brand | Agilent General (Safe, Fast, General) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic |
| Model | AT-RDLS10 |
| Price | USD 2,800 (FOB) |
| Brand | Agilent General |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AT-Z200 |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet Spectrophotometry (UV-Vis) |
| Measurement Range | 0.002–60 mg/L |
| Detection Limit | < 0.01 mg/L |
| Accuracy | ±2% (relative error) |
| Resolution | 0.001 mg/L |
| Analysis Cycle Time | 7 minutes per sample |
| Brand | Agilent General |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AT-H200 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0.002 – 64,000 mg/L |
| Detection Limit | < 0.2 mg/L |
| Accuracy | ±2% (relative error, certified reference standards) |
| Resolution | 0.001 mg/L |
| Analysis Time | 7 minutes per sample |
| Compliance | HJ 637–2018 (PRC Environmental Standard), JJF 1830–2020 (National Metrological Verification Regulation for Oil-in-Water Analyzers) |