Empowering Scientific Discovery

Anjie General Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeConfocal Micro-Raman Spectrometer
Excitation Wavelength785 nm
Spectral Range200–3350 cm⁻¹
Spectral Resolution4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹)
Spatial Resolution1 µm (lateral), 1 µm (axial)
Minimum Wavenumber200 cm⁻¹
Spectral Reproducibility≤ ±0.15 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandSafe
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelAT-X100
PortabilityHandheld / Field-Deployable
Elemental RangeMg to U
Quantification Range1 ppm – 99.99% (w/w)
Repeatability≤ 0.1% RSD
Detector OptionsSi-Pin or SDD (Selectable)
ComplianceDesigned for field-deployable environmental screening per EPA Method 6200, ASTM D7298, and China’s HJ 1003–2018]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelAT-Z300
Instrument TypeLaboratory-Based
Measurement PrincipleUltraviolet Spectrophotometry (UV-Vis)
Measurement Range0.002–64,000 mg/L
Limit of Detection (LOD)< 0.01 mg/L
Accuracy±0.2 mg/L
Resolution< 0.004 mg/L
Analysis Time per Sample7–12 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Spectrophotometry (Fourier-transform-free, Dispersive NIR with Fixed-Wavelength Detection at 2930, 2960, and 3030 cm⁻¹)
Measurement Range0.002–64,000 mg/L
Detection Limit< 0.04 mg/L
Accuracy±2% (relative error, certified reference materials)
Resolution0.002 mg/L
Analysis Cycle Time30 seconds per sample (including extraction solvent introduction, cell filling, and spectral acquisition)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeOEM/ODM Manufacturer
Instrument TypePortable Handheld Raman Spectrometer
ModelAT-RS200
Spectral Range200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis)
Spectral Resolution≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman)
Minimum Wavenumber200 cm⁻¹
Spectral Repeatability≤±0.15 cm⁻¹
Detection ModalitiesSurface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA)
Total Assay Coverage~600 analytes across food safety, environmental monitoring, and veterinary medicine
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeManufacturer
Regional ClassificationDomestic (China)
ModelHART375
Instrument TypeHART Protocol Field Communicator
Calibration TargetHART-enabled Pressure Transmitters, Temperature Transmitters, Flow Meters
DesignIntegrated Handheld Unit
Application EnvironmentIndustrial Plant Floors, Control Rooms, Field Maintenance Zones
Communication ModesPoint-to-Point, Multi-Drop (4–20 mA Loop), HART Primary Master Emulation
Supported DevicesAll HART Revision 5–7 compliant field instruments
Power SourceInternal Rechargeable Li-ion Battery (Typical Runtime: >12 h continuous operation)
Loop InterfaceBuilt-in 250 Ω precision resistor, loop-powered operation
Display3.5" TFT LCD (320 × 240 pixels), sunlight-readable with adjustable backlight
Environmental RatingIP65 (Dust-tight, water-jet resistant)
Operating Temperature–10 °C to +50 °C
ComplianceIEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Immunity), ATEX/IECEx Zone 2 / Class I Div 2 (Optional Certified Variant Available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeManufacturer
Regional ClassificationDomestic (China)
ModelAT-H300
Instrument TypeLaboratory
Measurement PrincipleInfrared Spectrophotometry (Fourier-transform-free, dual-beam fixed-wavelength absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹)
Measurement Range0.01–64,000 mg/L
Detection Limit0.01 mg/L
Accuracy±0.01 mg/L
Resolution0.004 mg/L
Sample Throughput7–10 minutes per sample
ComplianceHJ 637–2018, HJ 1051–2019, HJ 1077–2019, JJG 1153–2023
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelAT-AE06
Price RangeUSD 1,400 – 4,200
Extraction Efficiency0–100%
Extraction Time0–999 s
Oscillation MethodSealed, Clean Air Internal Circulation Agitation
Simultaneous Extraction Positions6
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelAT-AE06-Z
Extraction Efficiency0–99%
Extraction Time0–999 s
Agitation MethodClosed-loop Clean Air Oscillation
Simultaneous Extraction Capacity6 positions
Reagent Dispensing Range0–50 mL
Dispensing Accuracy≥2%
Sample Vessel Options250 / 500 / 1000 / 2000 mL (standard: 1000 mL)
Power Rating400 W
Voltage220 V ± 10%
Control Interface7-inch Color TFT Touchscreen
Waste HandlingIntegrated Activated Carbon Filtration for Liquid & Gaseous Effluents
Cleaning ModeWide-angle Pressurized Spray Rinse
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypePortable
Instrument CategoryFourier Transform
Wavenumber Range7800–350 cm⁻¹
Spectral Resolution0.01 cm⁻¹
Scan Speed1 scan per 60 seconds
Signal-to-Noise Ratio (SNR)45,000:1
Wavenumber Accuracy≤0.5 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSafe
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelAT-DX100
Instrument TypePortable
Biological Agent*Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria
Operating Temperature Range0–70 °C
Reagent Storage & Usage Temperature0–55 °C
Coefficient of Variation (CV)≤5%
Batch Capacity1–10 samples per run
Detection Time≤5 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent General (Safe, Fast, General)
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Origin CategoryDomestic
ModelAT-RDLS10
PriceUSD 2,800 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent General
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelAT-Z200
Instrument TypePortable
Measurement PrincipleUltraviolet Spectrophotometry (UV-Vis)
Measurement Range0.002–60 mg/L
Detection Limit< 0.01 mg/L
Accuracy±2% (relative error)
Resolution0.001 mg/L
Analysis Cycle Time7 minutes per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent General
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelAT-H200
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Measurement Range0.002 – 64,000 mg/L
Detection Limit< 0.2 mg/L
Accuracy±2% (relative error, certified reference standards)
Resolution0.001 mg/L
Analysis Time7 minutes per sample
ComplianceHJ 637–2018 (PRC Environmental Standard), JJF 1830–2020 (National Metrological Verification Regulation for Oil-in-Water Analyzers)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0