Empowering Scientific Discovery

Anrongxin Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAPT2000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
ModelLSS2014
Measurement PrincipleLaser Backscatter (90°–180° detection geometry)
MeasurandParticulate Matter (PM) in Flue Gas
Range0–20 mg/m³ (Ultra-Low Mode), Dual-Range Operation Supported
LOD0.05 mg/m³
Installation TypeIn-Situ, Non-Extractive
Gas Condition RequirementDry, Non-Condensing Flue Gas
Compliance ContextDesigned for continuous emission monitoring systems (CEMS) per Chinese HJ 76-2017 and compatible with international flue gas monitoring frameworks (e.g., EN 15267, ISO 12141, US EPA Method 9 and Performance Specification PS-11)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
ModelMB22-NH3
TypeOnline Gas Analyzer
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Sample Path TemperatureFully Heated to ≥180 °C (Adjustable)
Detection LimitSub-ppm Range (Typical LOD < 0.5 ppmv)
Response Time (T90)< 10 s
Optical PathMulti-Pass Herriott Cell with Pressure Compensation
Wavelength StabilizationIntegrated Reference Gas Cell
CalibrationFull-Path Zero/ Span Auto-Calibration
Environmental RatingIP65 Enclosure
Operating Temperature−20 °C to +50 °C
Power Supply220 VAC ±10%, 50/60 Hz
Output Interfaces4–20 mA, RS485, Modbus TCP, Optional Ethernet/Profibus
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelARX-MA100
Measurement PrincipleOptical Scattering (for Particulates), Electrochemical (for SO₂/NO₂/CO/O₃), Photoionization Detection (PID) for TVOC
Measured ParametersTSP, PM₁₀, PM₂.₅, NO₂, CO, SO₂, O₃, TVOC, Temperature, Relative Humidity, Wind Speed, Wind Direction, Atmospheric Pressure
Optional GasesNH₃, H₂S
Sampling PumpBrushless Vacuum Pump with Stable Flow Control
Sample ConditioningDynamic Heating System (DHS) with Real-time Temperature Feedback
Data TransmissionIndustrial-grade Multi-protocol Module (RS485, 4G LTE, Ethernet, LoRaWAN)
Alarm FunctionFull-range Configurable Thresholds with Dry Contact Output for Dust Suppression Integration (e.g., Fog Cannon Trigger)
ComplianceDesigned to Support ISO 12103-1, EPA EQOA-1 Reference Methods (for comparative monitoring), and GLP-aligned data logging architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
ModelAGA800
Measurement PrincipleUltraviolet Differential Optical Absorption Spectroscopy (UV-DOAS)
Installation TypeIn-situ probe-mounted
Response Time≤8 s
Operating Temperature (Probe)Up to 400 °C (heated optical path)
Target GasesSO₂, NO, NO₂ (total NOₓ)
CalibrationAutomated in-situ optical zero/span correction
Compliance ContextDesigned for continuous emission monitoring systems (CEMS) per HJ 75-2017 & HJ 76-2017 (China), compatible with ISO 12039, EN 15267, and EPA Method 6C/7E requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelARX-C200 / ARX-G310
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy±2% of Full Scale (F.S.)
Response Time≤ 200 s
Measured ParametersSO₂, NO, NO₂, O₂, Particulate Matter (PM), Flue Gas Temperature, Static Pressure, Flow Velocity, Relative Humidity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
ModelLFS800
Measurement PrincipleLaser Forward Scattering
Sample TypeWet Flue Gas
Measured ParameterParticulate Matter (PM)
Range0–5 mg/m³ (Low Range), Dual-Range Auto-Switching
Detection Limit0.01 mg/m³
Accuracy±10% (Gravimetric Reference Method)
Isokinetic Sampling Flow RateUp to 200 L/min
HeatingFull-Path Heated Sampling Line
CalibrationAutomated Zero and Span Calibration
DisplayIntegrated LED Interface
OutputAnalog 4–20 mA + Digital RS485/Modbus RTU
ComplianceDesigned for China’s HJ 75–2017 & HJ 76–2017 CEMS Technical Specifications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelARX-C200H
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy±2% F.S.
Response Time≤120 s
Measured ParametersSO₂, NO, NO₂, O₂, NH₃, Particulate Matter (PM), Temperature, Pressure, Flue Gas Velocity, Relative Humidity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTDP2021
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnronX
OriginJiangsu, China
ModelMB11
Instrument TypeOnline Gas Analyzer
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Optical TechniqueHigh-Frequency Scanned Wavelength Modulation Spectroscopy with Dual-Wavelength Differential Compensation
Operating EnvironmentHigh-Temperature In-Situ or Extractive Sampling
Sample HandlingHeated Probe + Heated Sample Line (up to 200 °C)
Interference ResistanceImmune to H₂O, CO₂, SO₂, NOₓ, and Particulate Obscuration
Output Interfaces4–20 mA Analog, RS485 Modbus RTU, Relay Status Outputs, Optional Integrated Humidity Sensor