Asphalt Physical Property Tester
Filter
Showing all 8 results
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest GmbH, a company of Anton Paar) |
| Product Category | Imported |
| Model | BPA |
| Price | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 256000/M, ASTM D6 |
| Power Supply | 220 V / 50 Hz, 2000 W |
| Temperature Range | Ambient to 180 °C ± 1 °C |
| Temperature Control Accuracy | ±0.1 °C (PID + Pt100 RTD) |
| Rotational Speed | 5.5 rpm (adjustable 5–6 rpm) |
| Internal Chamber Dimensions | 60 × 80 × 80 cm (W × H × D) |
| Net Weight | ~30 kg |
| Safety Certification | CE |
| Compliance Standards | ASTM D6, ASTM D1754, IP 145 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV-HT |
| Temperature Control Range | 40 °C to 150 °C |
| Kinematic Viscosity Measurement Range | 0.5 mm²/s (cSt) to 10,000 mm²/s (cSt) |
| Compliance Standards | AASHTO T201, ASTM D2170, ASTM D445 |
| Throughput | Up to 12 samples/hour |
| Software | VISCPRO® PC (supports up to 4 instruments per workstation) |
| Sample Preheater | Adjustable |
| Waste Line Heater | Integrated |
| Solvent Inlets | Dual standard ports |
| Calibration | Single-point temperature calibration capability |
| Capillary Exchange | Tool-free, operator-performed in minutes |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0777 |
| Test Temperature Range | 30–60 °C (±1 °C) |
| Applied Pore Water Pressure | 200–400 kPa (±30 kPa) |
| Sample Dimensions | Ø100–150 mm × 25–150 mm (diameter × height) |
| Power Supply | AC 220 V ±10%, 50 Hz, 1500 W |
| Operating Environment | 5–35 °C, RH ≤80% |
| Dimensions (L×W×H) | 530 × 530 × 1200 mm |
| Net Weight | 260 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS325 |
| Pricing | Available Upon Request |
| Brand | SCAVINI |
|---|---|
| Origin | Germany |
| Model | AD113 |
| Temperature Range | −10 °C to 40 °C |
| Ductility Extension Lengths | 50 cm, 100 cm, 150 cm |
| Load Measurement Range | 0–200 N |
| Load Resolution | 0.5 N |
| Temperature Control Accuracy | ±0.1 °C |
| Bath Material | Stainless Steel with PTFE-coated base |
| Cooling System | Integrated hermetic refrigeration compressor |
| Drive Mechanism | Variable-speed electric motor |
| Sample Capacity | 2 specimens simultaneously |
| Data Interface | RS-232 |
| Compliance | ASTM D113, ASTM D5976, IP 32, ISO 1208, GB/T 4508 |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SYD-2806H |
| Pricing | Upon Request |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | LF-1 |
| Standards Compliance | GB/T 12579–1990, ASTM D892–84, JIS K2518–1991 |
| Temperature Control | Dual-bath PID system (24 °C and 93.5 °C) |
| Bath Volume | Ø300 × 460 mm each |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W (24 °C bath), 2 × 1000 W (93.5 °C bath) |
| Cooling Input Power | 600 W |
| Working Medium | Distilled water |
| Stirring Motor Power | 25 W |
| Air Pump Power | 6 W |
| Gas Diffuser | Ø25.4 mm, pore size <80 µm, air permeability 3000–6000 mL/min |
| Graduated Cylinder | 1000 mL |
| Air Flow Rate | 94 ± 5 mL/min |
| Timer Resolution | 1 s |
| Power Supply | AC 220 V, 50 Hz |
| Total Rated Power | 3.3 kW |