Atomic Absorption Spectrometer
Filter
Showing 31–60 of 76 results
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | enduro Z-1000 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Adjustable Magnetic Field Strength | 0.6–1.0 T (0.1 T increments) |
| Lamp Holder | 8-position Auto-aligning |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Hollow Cathode & Electrodeless Discharge Lamp Recognition | Encoded |
| Ultra-Lamp Power Supply | 10 V (1 standard, up to 4 optional) |
| Resolution | <0.2 nm |
| Sensitivity | ≤0.003 absorbance units for Cu at 324.8 nm |
| Detection Limit | ≤0.5 pg for Cd in graphite furnace mode |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SavantAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.9 Abs for 5 mg/L Cu solution |
| Repeatability (RSD) | 0.45% |
| Detection Limit | ≤0.003 ppm for Cu |
| Lamp Holder | 8-position Automatic with Auto-Alignment |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Slit Height | Adjustable (Standard & Reduced) |
| Gas Control | Fully Automated with Safety Interlocks |
| D₂ Lamp Lifetime | Up to 10× Longer Than Conventional Lamps |
| Lamp Identification | Encoded HCL & EDL Recognition (Standard on SavantAA Σ, Optional on SavantAA) |
| EDL Power Supply | 10 V Optimized Design (1 Standard on SavantAA & SavantAA Si |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SensAA |
| Instrument Type | Flame-Graphite Furnace Hybrid AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.8 Abs for 5 mg/L Cu solution |
| Precision (RSD) | ≤0.5% |
| Detection Limit | Cu ≤ 0.005 mg/L |
| Light Source Configuration | 6-target hollow cathode lamp turret enabling up to 13 element combinations |
| Integrated Control | Built-in 15″ Windows-based touchscreen PC |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | XplorAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | <0.2 nm |
| Sensitivity | >0.8 A for 5 mg/L Cu solution |
| Precision (RSD) | <0.45% |
| Detection Limit | Sub-ppb for most elements with graphite furnace |
| Software Control | Handheld PC-based interface |
| Lamp Positions | 2 fixed hollow cathode lamp slots |
| Upgrade Path | Field-upgradable to graphite furnace and hydride generation systems |
| Brand | Haiguang Instrument |
|---|---|
| Type | Flame AAS |
| Background Correction | Zeeman-effect |
| Optical System | Single-beam with quasi-dual-channel reference |
| Monochromator | Concave grating |
| Detector | Photomultiplier tube (PMT) |
| Slit Width Options | 0.2, 0.4, 1.0, 2.0 nm |
| Magnetic Field | 1 T DC transverse configuration |
| Cooling | Water-cooled magnet assembly |
| Safety | Interlock and flashback arrestor systems |
| Software Platform | Windows 7/8-based control and data processing suite |
| Measurement Modes | Atomic absorption, Zeeman background correction, flame emission |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-600 |
| Instrument Type | Flame AAS |
| Monochromator | Echelle grating |
| Optical System | Double-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp background correction |
| Spectral Bandwidth | 0.2, 0.4, 1.0, 2.0 nm (auto-switchable) |
| Wavelength Range | 190–900 nm |
| Burner Head | Titanium alloy, 3D adjustable |
| Nebulizer | High-efficiency concentric glass nebulizer with impact bead |
| Spray Chamber | Corrosion-resistant treated mixed-type chamber |
| Safety Features | Gas cutoff interlock, flame-out protection, power failure auto-shutdown |
| Software Platform | Windows 7/8/XP compatible AAS control and data analysis suite |
| Compliance | GB 5009.x series, HJ 491-2019, HJ 757-2015, GB/T 17141-1997 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-610 |
| Instrument Type | Flame AAS |
| Monochromator | Concave Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Range | 190–900 nm |
| Flame Emission Capability | Yes (for K, Na, Li) |
| Safety Features | Automatic gas cutoff, flame failure interlock, flashback arrestor |
| Housing Material | Corrosion-resistant all-plastic enclosure |
| Software Platform | Windows 7/8/XP-compatible proprietary AAS control and data analysis suite |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-810 |
| Instrument Type | Flame AAS |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp (D₂) method |
| Burner Head | Titanium alloy |
| Atomization System | Full-plastic nebulizer chamber + high-efficiency glass concentric nebulizer |
| Safety Features | Water seal detection, waste liquid level monitoring, gas pressure monitoring, flame sensor, automatic gas cutoff on flameout, anti-flashback protection |
| Graphite Furnace Option | Longitudinal heating |
| Temp. range | ambient to 3000 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-820 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Single-beam |
| Monochromator | Plane grating (1800 lines/mm) |
| Focal Length | 270 mm |
| Background Correction | Deuterium (D₂) Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Atomizer | Integrated Flame/GF system (flame mode optional per GGX-830 reference) |
| Graphite Furnace Heating | Longitudinal |
| Temperature Range | Ambient to 3000 °C |
| Temperature Control Accuracy | ≤0.5% at 2000 °C |
| Maximum Ramp Rate | ≥2000 °C/s |
| Autosampler | 52-position, programmable matrix modifier addition, sample delivery precision ≤±0.5% |
| Safety Systems | Flame failure cutoff, gas pressure monitoring, liquid level sensing, water seal detection, anti-flashback design, automatic gas shutoff |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-830 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium (D₂) lamp |
| Burner Head | Titanium alloy |
| Graphite Furnace | Longitudinal heating, temperature range: ambient to 3000 °C, temperature control accuracy ≤0.5% at 2000 °C, ramp rate ≥2000 °C/s |
| Autosampler | 52-position graphite furnace autosampler with automated calibration curve generation, matrix modifier addition capability, and sample delivery precision ≤±0.5% |
| Safety Systems | Flame monitoring, gas pressure sensing, water seal detection, waste liquid level detection, anti-flashback protection, automatic fuel cutoff upon flameout |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-900 |
| Instrument Type | Flame AAS |
| Monochromator | Concave Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Range | 190–900 nm |
| Flame Atomization System | Titanium Alloy Burner, Corrosion-Resistant Hybrid Nebulizer Chamber, High-Efficiency Glass Concentric Nebulizer with Impact Bead |
| Safety Features | Gas/Air Interlock, Automatic Flame-Out Cutoff, Over-Temperature Alarm for Magnet Assembly, Water-Cooled Permanent Magnet |
| Software Platform | Windows 7/8/XP Compatible AAS Control & Data Analysis Suite with ASTM/ISO/GLP-Compliant Audit Trail, Excel Export, Multi-Mode Quantitation (Absorption, Background-Subtracted Absorption, Pure Background, Emission) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E30 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical Design | Czerny-Turner with 270 mm focal length and 1800 lines/mm grating |
| Slit Widths | 6 auto-switchable positions |
| Light Source | 8-lamp rotating turret with simultaneous preheating |
| Lamp Recognition | Automatic identification of hollow cathode lamps (HCL), self-reversal lamps, and high-performance lamps |
| Background Correction | D₂ lamp and self-absorption methods across full wavelength range (190–900 nm) |
| Atomization Modes | Flame (triple-gas flow control with safety interlock) and electrothermal graphite furnace (integrated power supply) |
| Autosampler | 84-position sliding-type flame/graphite furnace integrated autosampler |
| Software Functions | Auto-alignment, auto-peak search, auto-slit selection, startup diagnostics, and analytical condition recommendation |
| Optional Accessories | Hydride generation system for As, Hg, Se, Sb, Bi, etc. |
| Compliance | Fully supports GB, HJ, and ISO 8288, ISO 11170, ASTM D5059, USP <730>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E50 |
| Instrument Type | Flame–Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Safety Features | Over-Temperature Alarm, Low Gas Pressure Alert, Graphite Tube Break/Loose Clamp Detection |
| Automated Functions | Self-Check at Startup, Automatic Slit Adjustment, Peak Search, Lamp Positioning |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Flame AAS |
| Model | HD-AAS4H |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner enhanced optical system |
| Grating Density | 1800 lines/mm |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ≤ ±0.1 nm |
| Wavelength Repeatability | ≤ ±0.025 nm |
| Resolution | 0.2 nm (Cu 324.7 nm, 0.2 nm bandwidth) |
| Baseline Drift | 0.003 ABS/30 min (static), 0.005 ABS/15 min (dynamic) |
| Detector | Hamamatsu photomultiplier tube |
| Background Correction | Deuterium lamp |
| Characteristic Concentration (Cu) | 0.025 µg/mL/1% |
| Detection Limit (Cu) | 0.006 µg/mL |
| Precision (RSD) | ≤ 0.5% |
| Atomizer | Titanium 0.5 mm × 100 mm burner head |
| Nebulizer | High-efficiency glass nebulizer with metal cap |
| Spray Chamber | Corrosion-resistant all-plastic chamber |
| Safety System | Real-time acetylene leak detection, flame-out monitoring, gas pressure interlock, automatic shutdown |
| Lamp System | Motorized turret for 4/6/8 lamp positions |
| Data Interface | RS232, USB |
| Software | Windows-compatible AAS control suite with dual-language UI (EN/CN), remote calibration support, GLP-compliant audit trail, multi-format export (CSV, PDF, Excel) |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-1000 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Quasi-Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect (50 kHz) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A |
| RSD (Repeatability) | ≤0.3% |
| Detection Limit (Cu) | <0.006 µg/L |
| Max Graphite Furnace Temperature | 3000 °C |
| Heating Rate | Up to 7000 °C/s |
| Argon Flow Rate | <1 L/min (high-purity) |
| Wavelength Range | 185–900 nm |
| Typical LODs | Pb ≤0.05 µg/L, Cr ≤0.01 µg/L |
| Dimensions | 800 × 475 × 310 mm |
| Weight | 50 kg |
| Power Supply | 380 VAC, 50 Hz (3-phase) |
| Cooling | Integrated Closed-Loop Recirculating Water System |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-915MD |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A (for Cu at 324.8 nm) |
| RSD (Repeatability) | <0.3% |
| Detection Limit (Cu) | <0.006 mg/L |
| Detection Limits (Typical) | Pb ≤ 0.05 µg/L, Cr ≤ 0.01 µg/L |
| Max Graphite Furnace Temperature | 2950 °C |
| Max Heating Rate | 7000 K/s |
| Argon Flow Rate (Ultra-High Purity) | <1 L/min |
| Wavelength Range | 190–900 nm |
| Dimensions | 800 × 570 × 390 mm |
| Weight | 75 kg |
| Power Supply | 380 V AC, 50 Hz (3-phase) |
| Cooling | Closed-Loop Recirculating Water System |
| Power Consumption | <0.2 kW (standby/analysis), <18 kW (atomization/cleaning) |
| Brand | PerkinElmer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + AC Zeeman |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Flame (Cu): ≤0.02 µg/mL |
| GF-AAS (Cd) | ≤5.0×10⁻¹³ g |
| Precision (RSD) | Flame (Cu): ≤0.45% |
| GF-AAS (Cd) | ≤3.0% |
| Detection Limit | Flame (Cu): ≤0.003 µg/mL |
| GF-AAS (Cd) | ≤1.0×10⁻¹² g |
| Baseline Stability | ≤0.002 A/30 min (static) |
| Lamp Turret | 8-position Auto-rotating |
| Graphite Furnace | Transversely Heated |
| Magnetic Field | AC Zeeman, 0.6–1.1 T adjustable in 0.1 T increments |
| Optional Features | Integrated Graphite Furnace Viewing System |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Model | PinAAcle 500 |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam |
| Detector | Solid-State CCD Array |
| Background Correction | Deuterium Lamp |
| Flame System | FAST Flame Automated Burner Head Positioning and Gas Control |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Country of Origin | Imported |
| Model | PinAAcle 900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Longitudinal Zeeman |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PinAAcle D900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp Correction |
| Safety Interlocks | 7 Integrated Sensors |
| Automation | Dual-Mode Autosampler Compatible with Both Flame and GF Modes |
| Software Interface | Touchscreen-Controlled Method Wizard with Real-Time Camera Integration |
| Reporting | Customizable PDF Reports Including Calibration Curves and Sample Data |
| Brand | PerkinElmer |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | PinAAcle™ 950D |
| Pricing | Available upon request |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Wavelength Accuracy | ±0.15 nm |
| Baseline Stability | ±0.002 A/30 min (static) |
| RSD (Repeatability) | ≤0.6% for Cu (air-acetylene), ≤1.0% for Cu (LPG-air) and Ba (N₂O-acetylene), ≤2.0% for Cu and Cd (graphite furnace) |
| Characteristic Concentration | Cu < 0.02 µg/mL/1% (air-acetylene & LPG-air), Ba < 0.15 µg/mL/1% (N₂O-acetylene) |
| Detection Limit | Cu < 0.004 µg/mL (flame), Cd < 0.4 pg (graphite furnace) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Cu Sensitivity | >0.3 A at 5 ppm |
| Precision (RSD) | <0.4% |
| Cu Detection Limit | <0.004 µg/mL |
| Baseline Drift | <0.0008 A/30 min |
| Peak-to-Peak Baseline Noise | <0.0008 A/30 min |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | CPG2/CPG2S |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer (GFAAS) |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp Dual-Beam Background Correction |
| Detection Limits | Pb: 0.02 mg/kg, Cd: 0.002 mg/kg |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Wavelength Accuracy | ±0.25 nm |
| Spectral Bandwidth | ≤0.15 nm |
| Detection Limit (Flame, Cu) | 0.006 µg/mL |
| Detection Limit (GFAAS, Cd) | 1.0 pg |
| Characteristic Concentration (Cu) | <0.04 µg/mL per 1% absorption |
| Baseline Stability (Static) | ±0.004 A/30 min |
| RSD (Flame Cu) | <1% |
| RSD (GFAAS Cu) | <3.0% |
| RSD (GFAAS Cd) | <4.0% |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Persee General Instrument Co., Ltd. |
| Model | TAS-990 |
| Instrument Type | Dual-mode (Flame + Electrothermal Graphite Furnace) |
| Monochromator | Concave Grating |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-reversal Method |
| Wavelength Accuracy | ±0.25 nm |
| Baseline Stability (Static) | ±0.004 A / 30 min |
| RSD (Repeatability) | ≤1.0% (Flame, Cu), ≤3.0% (GFAAS, Cu) |
| Characteristic Concentration (Cu) | <0.04 µg/mL per 1% absorption |
| Detection Limit (Flame, Cu) | <0.006 µg/mL |
| Detection Limit (GFAAS, Cd) | <1.0 pg |
| Brand | PHXTEC |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AA68 A |
| Instrument Type | Flame AAS |
| Monochromator Element | Plane Grating |
| Optical System | Single-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Sensitivity | >0.3 A (for Cu 0.5 µg/mL) |
| Repeatability (RSD) | ≤0.5% |
| Detection Limit | 0.003 µg/mL (for Cu) |
| Baseline Stability | ≤0.002 A / 30 min |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3520AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Compliance | Meets GB/T 21187–2007 (Chinese National Standard for AAS), ASTM E1941, ISO 8288 |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3530AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Background Correction Capacity | >80× |
| Software Platform | Win-AAS Workstation |
| Data Output Modes | Time-Averaged Signal, Peak Height, Peak Area, Statistical Summary |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3590AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Single-beam, All-reflective Achromatic Optics |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-reversal (Self-absorption) Method |
| Safety Features | Automatic Lamp Switching, Graphite Tube Auto-diagnosis, Multi-point Radiation Shielding |
| Compliance | Designed for GLP-compliant laboratories |