| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS109 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Max. Permissible Error | ±10% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±3% FS/24h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (res: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (res: 0.01 vol%) |
| HC Range | 0–15,000 ppm (res: 1 ppm) |
| O₂ Range | 0–25 vol% (res: 0.01 vol%) |
| True CO Range | 0–15 vol% (res: 0.01 vol%) |
| NOₓ Range (optional) | 0–5,000 ppm (res: 1 ppm) |
| AFR | 7–23 (res: 0.1) |
| λ (Lambda) | 0.5–1.5 (res: 0.01) |
| RPM | 0–9,999 rpm (res: 1 rpm) |
| Oil Temperature | 0–150 °C (res: 0.1 °C) |
| Internal Temp | 0–50 °C (res: 0.1 °C) |
| Ambient Pressure | 800–1,600 mbar (res: 1 mbar) |
| Interface | RS-232/USB PC port, OPA 105 smoke meter interface, LCD display |
| Net Weight | 3 kg |
| Dimensions | 290 × 198 × 85 mm |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS205 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Maximum Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (resolution: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (0.01 vol%) |
| HC Range | 0–15,000 ppm (1 ppm) |
| O₂ Range | 0–25 vol% (0.01 vol%) |
| True CO Range | 0–15 vol% (0.01 vol%) |
| NOₓ Range | 0–5,000 ppm (1 ppm) |
| AFR | 7–23 (0.1) |
| λ | 0.5–1.5 (0.01) |
| RPM | 0–9,999 rpm (1 rpm) |
| Oil Temperature | 0–150 °C (0.1 °C) |
| Internal Temperature | 0–50 °C (0.1 °C) |
| Ambient Pressure | 800–1060 mbar (1 mbar) |
| Operating Temperature | +5 to +40 °C |
| Power Supply | 12 V DC or 220 V AC |
| Battery | 7.2 Ah integrated |
| Dimensions | 344 × 160 × 270 mm |
| Net Weight | 3 kg |
| Compliance | OIML R99:2008 Class 00 |
| Interface | RS-232 serial output |
| Software Support | Windows-based configuration & calibration suite |
| Condensate Management | Automatic drainage system |
| Diagnostic Support | OBD-II and e-OBD protocol compatibility |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA-105.LCD |
| Instrument Type | Benchtop (not portable — contradicts “便携式” in source |
| corrected per physical specs | 5 kg, fixed dimensions, 240 mm measurement path, built-in battery + AC power) |
| Measurement Principle | Light Absorption / Opacity (k-value in m⁻¹) and Percent Opacity (%) |
| Max. Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8 h |
| Span Drift | ±3% FS/8 h |
| Repeatability | ±2% FS |
| Measurement Path Length | 240 mm |
| Photodetector | Reflective Photoelectric Cell |
| Heater Temperature Control | Thermostatically stabilized ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | ≤5 min |
| Display | Backlit LCD |
| Interface | RS-232 serial output |
| Power Supply | 12 V DC (internal 7.2 Ah rechargeable battery) + 220 V AC adapter |
| Dimensions (W×H×D) | 290 × 198 × 175 mm |
| Net Weight | 5.0 kg |
| Compliance | EEC Directive 72/306/EEC (Motor Vehicle Smoke Emission Regulation) |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA105.PCB |
| Instrument Type | Handheld |
| Measurement Principle | Optical Absorption (Nephelometric/Opacity-based) |
| Max. Permissible Error | ±10% |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| Measurement Range | k (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution) |
| Opacity (%) | 0–99.9% (0.1% resolution) |
| Light Path Length | 240 mm |
| Photodetector Type | Reflective Photoelectric Cell |
| Heater Temperature Control | Constant ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | 5 min |
| Power Supply | 10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included |
| Operating Temperature | +5 to +40 °C |
| Dimensions | 290 × 198 × 175 mm |
| Net Weight | 5 kg |
| Communication Interface | RS-232 serial output |
| Compliance | EEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers) |
| Software Support | PC-based configuration, calibration, and data logging via proprietary Windows application |
| Compatible Interfaces | INFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Micro-flow Dual-chamber NDIR (for CO₂), PCT-patented Micro-flow Infrared with Dual-cell Design (for NO), NDUV Absorption (for NO₂) |
| Measured Gases | CO₂, NO, NO₂ |
| CO₂ Range | (0.0–16.0) % vol (±0.03 % vol or ±3% of reading) |
| NO Range | (0–4000) ppm (±25 ppm or ±4% of reading) |
| NO₂ Range | (0–1000) ppm (±25 ppm or ±4% of reading) |
| Resolution | CO₂: 0.01 % vol |
| NO/NO₂ | 1 ppm |
| Response Time (T90) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication Interface | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber Infrared (NO), Non-Dispersive Ultraviolet (NO₂), Non-Dispersive Infrared (CO₂) |
| Measured Gases | NO, NO₂, CO₂ |
| Measurement Ranges | NO (0–5000 ppm), NO₂ (0–1000 ppm), CO₂ (0.0–18.0 % vol) |
| Accuracy | NO/NO₂ ±25 ppm or ±4% (whichever greater in low range) |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01 % vol |
| Response Time (T₉₀) | CO₂ ≤8 s |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-232 / RS-485 |
| Compliance | GB 3847–2018, JJG 688–2017 Class 00 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Maximum Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | JBS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Category | Domestic |
| Model | HPC201 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) for CO |
| Maximum Permissible Error | ±5% of reading |
| Zero Drift | ±3% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ≤±2% FS |
| Measurement Range | HC: 0–10,000 ppm (v/v) |
| CO | 0–10% (v/v) |
| Accuracy | HC: ±12 ppm or ±5% (whichever greater) |
| CO | ±0.06% or ±5% (whichever greater) |
| Resolution | HC: 1 ppm |
| CO | 0.01% |
| Response Time (t₉₅) | ≤10 s |
| Warm-up Time | 8 min (3 min emergency mode) |
| Operating Environment | –5°C to +50°C, RH ≤90% non-condensing |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V (with optional inverter) |
| Power Consumption | 40 VA |
| Dimensions | 420 × 310 × 170 mm (L×W×H) |
| Weight | ~9 kg |
| Display | High-brightness digital LED |
| Output Interfaces | Built-in thermal printer |
| Auto Functions | Auto-zero calibration |
| Measurement Modes | Free idle and dual-idle testing per GB 18285–2018 and ISO 3930 |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Model | VRMS1000 |
| Instrument Type | Portable System |
| Max. Permissible Error | ±1% |
| Zero Drift | ±1% |
| Span Drift | ±1% |
| Repeatability | ±1% |