| Brand | Biotage |
|---|---|
| Origin | USA |
| Model | V-10 Touch |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 0–1000 mL |
| Built-in Vacuum Pump | 2 mbar ultimate pressure |
| Maximum Rotor Speed | 8000 rpm |
| Brand | Biotage |
|---|---|
| Origin | USA |
| Model | TurboVap LV |
| Type | Automated Nitrogen Evaporation System |
| Sample Capacity | Up to 50 samples per run |
| Tube Compatibility | 10×75 mm to 20×150 mm |
| Temperature Control Range | Ambient to 90 °C (±0.5 °C accuracy) |
| Gas Flow Control | Independent, digitally regulated nitrogen flow per position (0–20 L/min total) |
| Evaporation Endpoint Detection | Optical endpoint sensing (photoelectric detection of solvent meniscus) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Initiator+ Alstra |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Reaction Vessel Count | 1 |
| Reaction Volume | 30 mL |
| Synthesis Scale | 5 μmol – 2 mmol |
| Control Interface | 10-inch Touchscreen |
| Reagent Delivery | Digital Metering Pumps |
| Mixing Method | Orbital Shaking |
| Vessel Type | Disposable Cartridges |
| Atmosphere Control | Inert Gas (N₂/Ar) Compatible |
| UV Monitoring | Integrated |
| Supported Chemistries | Fmoc & Boc Solid-Phase Peptide Synthesis (SPPS) |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Dalton 2000 |
| Application Level | Laboratory |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤ 2 × 10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Mass Range | m/z 80–2000 |
| Ionization Modes | Simultaneous Positive/Negative APCI (ESI optional) |
| Brand | Biotage |
|---|---|
| Origin | USA |
| Model | RapidTrace |
| Configuration | Modular, Up to 10 Units Scalable |
| Throughput | 40–100 Samples/Hour (10-Module Configuration) |
| Sample Capacity per Module | Up to 10 Samples |
| Solvent Channels per Module | 8 |
| Cartridge Compatibility | 1 mL, 3 mL, and 6 mL SPE cartridges (standard fritted or polypropylene housing) |
| Eluent Delivery | Positive-pressure-driven, flow-controlled |
| Waste Segregation | 4 Independent Waste Lines (Organic, Inorganic, Biological, Hazardous) |
| Integrated Reagent Mixing Chamber | Yes, with pH-adjustment capability |
| Software Interface | Menu-driven, method-centric, audit-trail enabled |
| Regulatory Compliance Support | FDA 21 CFR Part 11–ready, GLP/GMP-aligned workflow logging |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera LS |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 50–500 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi (10 bar) |
| Wavelength Range | 200–400 nm (standard UV), optional 200–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |