| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Max Capacity | 220 g / 121 g (dual-range) |
| Readability | 1 mg / 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| External Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| User Management | Password-protected, unlimited users, role-based permissions |
| Software Compatibility | LabX™ (21 CFR Part 11 compliant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg (certified: 1 mg) |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| External Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| User Management | Password-protected, unlimited users, role-based permissions |
| Compliance | 21 CFR Part 11–ready (with LabX), USP <41> compliant, GLP/GMP-supportive |
| Electrostatic Detection | Not supported |
| Series | XPR Essential |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g / 81 g (dual-range) |
| Readability | 0.1 mg / 0.01 mg |
| Repeatability (typ.) | 0.01 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 20 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B, Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Series | XPR Essential |
| Regulatory Compliance | 21 CFR Part 11–compatible (with LabX), USP <41>, ISO/IEC 17025 support |
| User Management | Password-protected, unlimited users, role-based permissions |
| Static Detection | Not integrated |
| Industry Applications | Pharmaceuticals, Chemicals, Food & Beverage, Quality Control Laboratories |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g / 121 g |
| Readability | 0.1 mg / 0.01 mg |
| Repeatability (typ.) | 0.01 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 20 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, Fully Automatic (FACT) |
| Interfaces | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Display | 7-inch color TFT touchscreen |
| User Management | Password-protected, unlimited users, configurable permissions |
| Pan Dimensions (W × D) | 78 mm × 73 mm |
| Dimensions (H × W × D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Electrostatic Detection | Not supported |
| Product Line | XPR Essential |
| Regulatory Compliance | 21 CFR Part 11–ready (with LabX software), USP <41> compliant, GLP/GMP traceable operation |
| Recommended Industries | Pharmaceuticals, Chemicals, Food & Beverage |
| Key | Brand: METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR226DRQ |
| Type | Analytical Balance |
| Max Capacity | 220 g |
| Readability | 2 µg |
| Accuracy | 5 µg |
| Repeatability | 0.01 mg |
| Calibration | Internal motorized calibration |
| Application | Automated gravimetric dispensing and quantitative sample preparation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR26/56 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.0003 mg |
| Calibration | Automatic (proFACT) |
| Compliance | USP Chapter <41> & <1251>, ISO/IEC 17025, GWP® Verified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| External Dimensions (H × W × D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| User Management | Password-protected, unlimited users, configurable permissions |
| Compliance | 21 CFR Part 11–compatible (via LabX), USP <41> compliant, GLP/GMP-ready |
| Series | XPR Essential |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Ultra-Micro Balance |
| Model | XPR3DUE/AC |
| Maximum Capacity | 3.2 g / 1.2 g |
| Readability | 0.01 mg / 0.001 mg |
| Repeatability (typ.) | 0.0008 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 1.6 mg |
| Stabilization Time | 6 s |
| Pan Dimensions (W × D) | 32 mm × 32 mm |
| Dimensions (H × W × D) | 196 mm × 195 mm × 478 mm |
| Built-in Calibration | FACT (Fully Automatic Calibration Technology) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B, Ethernet, Bluetooth (optional) |
| 21 CFR Part 11 Compliance | Yes (with LabX software) |
| User Management | Unlimited users with role-based permissions |
| Leveling Guidance | Integrated digital level indicator |
| Static Detection | Not automated |
| Minimum Weight (U=1%, k=2, typ.) | 0.16 mg |
| Certified Readability | 1 mg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR603SN |
| Maximum Capacity | 610 g |
| Readability | 1 mg |
| Repeatability | 0.5 mg |
| Calibration | Internal |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible (via LabX), ISO/IEC 17025 support |
| Sample Pan Type | SmartPan™ |
| Leveling System | LevelMatic™ |
| Connectivity | Ethernet, USB, RS232 |
| Data Integrity | LabX-integrated, audit trail enabled, electronic signature support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Micro Balance |
| Readability | 0.001 mg / 0.01 mg (dual range) |
| Max Capacity | 0.8 g / 3.1 g (dual range) |
| Repeatability (sd) | 0.0008 mg / 0.006 mg |
| Linearity Error | ±0.01 mg |
| Typical Stabilization Time | 6 s |
| Pan Diameter | Ø27 mm |
| Design | Separated weighing unit and display/control unit |
| Built-in Applications | Weighing, Statistics, Formulation, Counting, Percentage, Density, Dynamic Weighing |
| Compliance | GWP® Excellence integrated risk-based validation support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Precision Balance |
| Model Series | XS |
| Sensor Technology | MonoBloc HighSpeed single-module electromagnetic force compensation sensor |
| Readability | 0.1 mg to 1 g |
| Max Capacity | 210 g to 100 kg |
| Repeatability (sd) | 0.0008 mg to 0.6 g |
| Linearity Error | 0.002 mg to 0.3 g |
| Stabilization Time | 1.2 s to 1.5 s |
| Pan Dimensions (W×D) | 127×127 mm to 280×360 mm |
| Protection Class | IP54 |
| Construction | Full-metal monocoque frame with rounded edges and seamless, flat surfaces |
| Interface Options | RS232 (standard), plus modular slot for Bluetooth, Ethernet, PS/2, LocalCAN, or MiniMettler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Series |
| Instrument Type | Analytical Balance |
| Capacity Range | 41–220 g (dual-range and single-range variants) |
| Readability | 0.01 mg to 0.1 mg |
| Repeatability (sd) | 0.02 mg to 0.1 mg |
| Linearity Error | ≤ 0.2 mg |
| Typical Stabilization Time | 1.5–4 s |
| Pan Dimensions | 78 × 73 mm (standard) |
| Key | Brand: METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS203S |
| Maximum Capacity | 210 g |
| Readability | 0.001 g |
| Linearity (typ.) | ±0.002 g |
| Repeatability (at 200 g) | 0.5 mg |
| Minimum Weight (USP, typ.) | 1 g |
| Stabilization Time | 1.5 s |
| Pan Dimensions (D×W) | 127 mm × 127 mm |
| Overall Dimensions (H×W×D) | 276 mm × 198 mm × 305 mm |
| Weighing Chamber | None (open design with SmartPan™) |
| Calibration | Internal, FACT (Fully Automatic Calibration Technology) |
| Compliance | ISO/IEC 17025, USP <41> & <1251>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS4001S |
| Instrument Type | Precision Balance |
| Maximum Capacity | 4.1 kg |
| Readability | 0.1 g |
| Linearity (typ.) | ±60 mg |
| Repeatability (typ.) | 40 mg |
| Repeatability (2 kg test weight) | 80 mg |
| Minimum Weight (USP, typ.) | 82 g |
| Stabilization Time | 0.8 s |
| Calibration | Internal / FACT |
| Pan Dimensions (D×W) | 190 mm × 223 mm |
| Housing Dimensions (H×W×D) | 96 mm × 195 mm × 257 mm |
| Display Height | 16 mm digits |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS8001S |
| Maximum Capacity | 8.1 kg |
| Readability | 0.1 g |
| Linearity (typ.) | ±0.1 g |
| Repeatability (typ.) | 40 mg |
| Repeatability (with 5 kg test weight) | 80 mg |
| Minimum Weight (USP, typ.) | 82 g |
| Stabilization Time | 1 s |
| Calibration | Internal / FACT |
| Pan Dimensions (D×W) | 190 mm × 223 mm |
| Housing Dimensions (H×W×D) | 96 mm × 194 mm × 257 mm |
| Display Digit Height | 16 mm |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Model | XSR |
| Compliance | ISO/IEC 17025, USP <41>, USP <1251>, ASTM E898, GLP/GMP-ready |
| Software | LabX®-compatible, FDA 21 CFR Part 11 compliant (with optional audit trail license) |
| Weighing Range | Up to 520 g (model-dependent) |
| Readability | 0.001 mg to 0.01 mg |
| Repeatability (sd) | ≤ 0.0006 mg (typical) |
| Calibration | Internal & external, fully traceable to SI units |
| Draft Shield | Motorized automatic draft shield with SmartDoor™ logic |
| Pan Design | SmartGrid™ perforated weighing pan |
| Connectivity | USB, RS232, Ethernet, Bluetooth (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR Precision Balance |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Readability | Down to 0.1 mg–1 mg (model-dependent) |
| Repeatability | ≤ 0.0002 g (at full capacity) |
| Internal Calibration | FACT (Fully Automatic Calibration Technology) with motorized weights |
| Environmental Compensation | Built-in temperature and drift monitoring |
| Connectivity | 4× USB-A, 1× Ethernet (LAN), optional RS-232 |
| Data Security | User-level password protection, audit trail enabled, 21 CFR Part 11 compliant configuration available |
| SmartPan™ | Patented draft shield-free weighing pan design reducing air current interference |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Analytical Balance |
| Model Range | XSR105, XSR105DU, XSR205DU, XSR64, XSR104, XSR204, XSR204DR, XSR304, XSR225DU |
| Maximum Capacity | 61–320 g (full range) |
| Readability | 0.01 mg (high-resolution models) to 1 mg |
| Repeatability (sd, 5% load) | 0.008–0.04 mg |
| Stabilization Time | 1.5–3 s |
| Minimum Weight (USP <41> compliant) | 16–82 mg |
| Calibration | proFACT — fully automatic, time- and temperature-triggered internal calibration |
| Display | Full-color touchscreen with multilingual UI (including English) |
| Connectivity | 4 × USB ports, 1 × Ethernet (LAN) port |
| Environmental Control | Active Temperature Control (ATC™), LevelControl™ leveling system, SmartGrid™ draft shield grid |
| Compliance | USP <41>, GWP® Verified, GLP/GMP-ready audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR105 |
| Instrument Type | Precision Balance |
| Readability | 1 mg |
| Construction | Full-metal corrosion-resistant housing |
| Pan System | SmartPan™ with integrated spill containment tray |
| Draft Shield Operation | Optional — door can remain open during weighing in fume hoods or under laminar flow |
| Compliance | Designed for GLP/GMP environments |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | AX Series |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g to 8200 g |
| Readability | 0.1 mg to 0.1 g |
| Calibration | Internal (AutoCal™) or External |
| Repeatability | 0.1 mg to 0.1 g |
| Linearity Error | ±0.0002 g to ±0.2 g |
| Stabilization Time | ≤1.5 s to ≤3 s |
| Accuracy Class | ISO 9001-certified manufacturing |
| Operating Temperature | 10–30 °C |
| Humidity Range | ≤80% RH at ≤30 °C, linearly decreasing to 50% RH at 40 °C |
| Display | 4.3-inch WQVGA capacitive touchscreen (10.9 cm diagonal) |
| Interface | RS-232, dual USB (front-facing for USB flash drive, rear for PC connection) |
| GLP/GMP Compliance | Real-time clock, user-defined audit trail metadata (sample ID, project name, operator), time-stamped data export |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | i-D33P60B1R1ZH |
| Pricing | Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | i-D33P300B1V3ZH |
| Pricing | Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DF52P1500HLXZH |
| Pricing | Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DF52XW1500WLXZH |
| Pricing | Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DF52XW5000WVZH |
| Pricing | Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Product Line | EXPLORER |
| Instrument Type | Analytical/Micro Balance |
| Maximum Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability (sd) | 0.01 mg (at 20 g), 0.02 mg (at 100 g) |
| Linearity Error | ±0.1 mg |
| Calibration | Internal AutoCal™ with dual internal calibration weights |
| Stabilization Time | ≤8 s (0.01 mg models) |
| Minimum Weight (USP, u=0.10%, k=2) | 20 mg (typical), 9 mg (optimized) |
| Temperature Drift | 0.80 ppm/°C |
| Display | 5.7″ VGA color touchscreen |
| Connectivity | Dual USB + RS232 (standard), optional Ethernet |
| Compliance | GLP/GMP-ready, supports 21 CFR Part 11 audit trail via optional software |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | EXPLORER Professional Balance |
| Instrument Type | Precision Balance |
| Maximum Capacity | 12 kg |
| Readability | 0.1 g |
| Repeatability | 0.1 g |
| Linearity Error | ±0.2 g |
| Stabilization Time | ≤1 s |
| Calibration | Internal AutoCal™ (triggered every 11 h or upon ΔT ≥1.5 °C) |
| Protection Rating | IP54 (base unit) |
| Accuracy Class | Class II (per OIML R76) |
| Minimum Weight (USP <781>, K=2, U=0.10%) | 160 g |
| Operating Temperature | 10–30 °C |
| Humidity Range | 15–80% RH (non-condensing, ≤30 °C) |
| Display | 5.7″ color VGA TFT resistive touchscreen |
| Interface | RS-232, USB host/device |
| Data Export | Direct save to USB drive (TXT, CSV) |
| Software | SmartText™ 2.0 with 14 GLP/GMP-compliant weighing applications |
| Compliance | Fully supports FDA 21 CFR Part 11 audit trail requirements via optional software configuration |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | NVT6200ZH |
| Instrument Type | General-Purpose Portable Balance |
| Maximum Capacity | 6200 g |
| Readability | 1 g |
| Repeatability | ±1 g |
| Calibration Method | External |
| Overload Protection | Up to 400% of rated capacity |
| Transport Lock | Integrated mechanical sensor lock |
| Compliance | Designed to meet ISO 9001 manufacturing standards and supports GLP/GMP documentation workflows |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | NAVIGATOR |
| Instrument Type | Precision Balance |
| Maximum Capacity | 620 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | Internal |
| Overload Protection | Up to 400% of maximum capacity |
| Stabilization Time | As fast as 1 second |
| Construction | High-strength ABS housing with SUS 304 stainless steel pan |
| Power | AC adapter (included) or 4 × AA batteries (270-hour battery life) |
| Operating Environment | 10–40 °C, 10–85% RH (non-condensing) |
| Communication Options | Optional RS232, USB, or Ethernet interface |
| Display | Backlit LCD with 20 mm digit height |
| Dimensions (W×D×H) | 204 × 230 × 70 mm |
| Net Weight | 1.0 kg |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | NV622ZH |
| Instrument Type | General-Purpose Portable Balance |
| Capacity Range | 200–500 g |
| Readability | 0.01 g |
| Repeatability | ±0.02 g |
| Maximum Overload Capacity | 400% of full scale (up to 2480 g) |
| Calibration | External |
| Protection Class | IP42 (dust and splash resistant) |
| Power Supply | AC adapter or 4 × AA batteries (optional) |
| Tare Range | Full capacity |
| Weighing Units | g, oz, ct, dwt, lb, ozt, GN, momme, tola, tael (HK/SG), tl (TH), kg |