| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AD-4212C-300 |
| Instrument Type | Analytical Balance Module |
| Capacity Range | 200–500 g |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ≤0.001 g |
| Stabilization Time | 0.5 s |
| Data Output Rate | 50 Hz |
| Protection Rating | IP65 |
| Housing Material | Stainless Steel |
| Pan Dimensions | 50 mm × 50 mm |
| Interface Options | Analog Output / Comparator Output / BCD Output |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AD-4212C-301 |
| Instrument Type | Analytical Balance Module |
| Capacity | 51 g / 320 g |
| Readability | 0.0001 g / 0.001 g |
| Repeatability | ≤ 0.0002 g / ≤ 0.001 g |
| Pan Size | 50 mm × 50 mm |
| Stabilization Time | 0.5 s |
| Data Output Rate | 50 Hz |
| Protection Rating | IP65 |
| Housing Material | Stainless Steel |
| Interface Options | Analog Output / Comparator Output / BCD Output |
| Mounting Width | 59 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4401 |
| Display Resolution | 1/16,000 |
| Internal A/D Resolution | 1/1,000,000 |
| Sampling Rate | 100 Hz |
| Input Sensitivity | 0.3 µV/d |
| IP Rating | IP65 (Front Panel) |
| Communication Interfaces | RS-232 (Current Loop & Optional TTL), RS-422/485 (Optional), BCD (Optional), 4–20 mA Analog Output (Optional) |
| Max Device Count on RS-422/485 Network | 10 units |
| Operating Modes | 8 Predefined Weighing & Control Modes |
| Built-in Diagnostics | I/O, A/D, Peripheral Detection |
| Auto-Compensation | Fuzzy Logic-Based Drop Compensation & Re-Feed Control |
| Data Logging | Batch Weight Summation & Cycle Count Accumulation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4402 |
| Sampling Rate | 100 Hz |
| Internal A/D Resolution | 1:1,000,000 |
| Display Resolution | 1:16,000 |
| Input Sensitivity | 0.3 µV/d |
| IP Rating | IP65 (Front Panel) |
| Programmable Recipes | 100 |
| Stored Materials | 100 |
| I/O Channels | 11 inputs / 11 outputs |
| Configurable Functions | 50 |
| Alarm Outputs | 8 |
| Communication Interfaces | RS-232, RS-422/485, BCD, Parallel I/O, Analog Output, CC-Link, DeviceNet, PROFIBUS |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-8121B |
| Printing Technology | Serial Dot-Matrix |
| Character Format | 5×7 dot matrix (2.5 mm H × 1.8 mm W) |
| Characters per Line | 16 |
| Interface Options | RS-232C or Current Loop (20 mA) |
| Power Supply | AC adapter or 4×AA alkaline batteries |
| Programmable Interval Printing | 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 30 min |
| Statistical Functions | Min, Max, Mean, Standard Deviation, Coefficient of Variation, Range |
| Print Head Lifetime | Approx. 500,000 lines |
| Dimensions (W×D×H) | 180 × 160 × 80.5 mm |
| Weight | ~1.2 kg |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BA-6TE |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 6.2 g |
| Readability | 1 µg (0.000001 g) |
| Repeatability | ≤ 0.001 mg |
| Calibration Method | Internal Motorized Auto-Calibration with Built-in Weights |
| Minimum Weight Detection | Auto-Verified per USP <41> |
| Static Elimination | DC Ionizer-Free Electrostatic Neutralization |
| Compliance | GLP/GMP/GCP/ISO Data Output Format |
| Environmental Monitoring | Real-Time Ambient Temperature & Humidity Tracking |
| Connectivity | RS-232, USB, Ethernet, Optional GPIB and PLC I/O |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Semi-Micro Analytical Balance |
| Model | BH225TE |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.015 mg (at 50 g), 0.03 mg (at 200 g) |
| Internal Calibration | Yes |
| Stabilization Time | ~7 s |
| Pan Diameter | Ø90 mm |
| Net Weight | ~8 kg |
| Compliance | GLP/GMP/GCP/ISO-compliant data output, USP <41> and <1251> compliant minimum weight assessment, FDA 21 CFR Part 11 ready (with optional audit trail software) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Ultra-Micro Balance |
| Capacity | 520 g |
| Readability | 1 µg |
| Repeatability | ≤ ±0.001 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Interface | RS-232C and USB (dual simultaneous output) |
| Data Storage | 200 measurement records (100 timestamped), 50 calibration logs |
| Display | High-contrast white-backlit LCD |
| Draft Shield | Conductive-coated mesh-patterned glass with electrostatic neutralization (integrated ionizer) |
| Brand | A&D |
|---|---|
| Origin | Tianjin, China |
| Model | CL102 |
| Max Capacity | 100 g |
| Readability | 0.01 g |
| Repeatability | ±0.01 g |
| Linearity Error | ±0.02 g |
| Stabilization Time | ≤2.5 s |
| Pan Diameter | φ115 mm |
| Dimensions (W×D×H) | 186 × 275 × 87 mm |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 10–70 %RH |
| Warm-up Time | 30–60 min |
| Power Input | 220 V AC / 50 Hz |
| Output | 12 V DC / 1 A |
| RS232 Baud Rates | 300–9600 |
| Accuracy Class | Class II |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Intrinsically Safe Laboratory Balance |
| Model | EK-300EP |
| Max Capacity | 300 g |
| Readability | 0.01 g |
| Repeatability | ≤ ±0.01 g |
| Calibration | External |
| Weighing Units | g, oz, ct, dwt, tl, ozt, lb, GN |
| Display | High-contrast LCD with 16 mm digit height |
| Power | 4 × AA alkaline batteries (up to 250 h continuous operation) |
| Pan Material | Washable stainless steel |
| Auto Power-Off | Yes |
| Certifications | IECEx Ex ia IIB T3 Ga |
| FM/FMc (NEC 505) | AEx / Ex ia IIB T3 |
| FM/FMc (NEC 500) | IS / I / 1 / C,D / T3C |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-120i / EK-200i / EK-300i / EK-410i / EK-610i / EK-600i / EK-1200i / EK-2000i / EK-3000i / EK-4100i / EK-6100i / EK-6000i / EK-12Ki |
| Capacity Range | 120 g – 12,000 g |
| Readability | 0.01 g – 1 g |
| Display | Backlit LCD with 60,000 internal resolution |
| Interface | RS-232C standard |
| Compliance | GLP, GMP, ISO 9001 |
| Power Options | AC adapter or optional rechargeable Li-ion battery |
| Software Compatibility | Win-CT for data logging and instrument control |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-iD/GF-D |
| Measurement Principle | Archimedes’ Principle |
| Weighing Range | 300 g to 3100 g (model-dependent) |
| Readability | 0.001 g to 0.1 g |
| Density Resolution | 0.001 g/cm³ |
| Repeatability | ±0.002 g/cm³ |
| Display | High-contrast LCD (EK-iD) / Fluorescent display (GF-D), 16 mm digit height |
| Stabilization Time | 1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Weighing Pan Size | 108 × 80 mm |
| Interface | RS-232 standard port |
| Software | WinCT for Windows (data logging, statistical analysis, Excel export) |
| Compliance | Built-in GLP/GMP/ISO audit trail support |
| Environmental Adaptation | Adjustable response speed (FAST/MID/SLOW) |
| Power Options | AC adapter or rechargeable battery (EK-iD only, up to 10 h operation) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Product Type | Imported Precision Balance |
| Model | FX-1200CT |
| Instrument Category | Analytical/Precision Balance |
| Maximum Capacity | 1260 ct / 252 g |
| Readability | 0.001 ct / 0.1 mg |
| Repeatability | ≤ ±0.001 ct / ±0.2 mg |
| Calibration | External |
| Stabilization Time | ≤ 2 s |
| Display | Backlit High-Contrast LCD with Large Digits |
| Interface Options | RS-232C, USB (FXi-02), Ethernet (WINCT-Plus), Optional Rechargeable Battery (FXi-09) |
| Dimensions (W×D) | 198 × 294 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | External Calibration Precision Balance |
| Max Capacity | 3200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Stabilization Time | ~1 s |
| Pan Diameter | Ø150 mm |
| Dimensions (W×D×H) | 193 × 262.5 × 85.5 mm |
| Protection Rating | IP65 |
| Interface | RS-232, USB (driver-free), optional Ethernet |
| Software | WinCT-Plus (standard WinCT included) |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP data traceability support |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | FX-GD |
| Capacity Range | 122 g to 3200 g (model-dependent) |
| Readability | 0.001 g or 0.01 g |
| Repeatability | ±0.001 g or ±0.01 g |
| Linearity | ±0.002 g or ±0.02 g |
| Pan Diameter | 130 mm or 150 mm |
| Dimensions (W×D×H) | 193 × 262.5 × 85.5 mm |
| Weight | ~2.5 kg |
| Interface | USB (driver-free), Ethernet (with WinCT-Plus software), optional built-in rechargeable battery (FXi-09 variant) |
| Display | High-contrast fluorescent LCD |
| Units | g, pcs, %, ct, mom |
| Compliance | GLP, GMP, ISO 9001, ISO/IEC 17025 applicable |
| Stabilization Time | ≤1 s |
| Statistical Functions | Counting, % weighing, piece counting, net/gross/tare |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | FX-120i / FX-1200i |
| Capacity | 122 g / 1220 g |
| Readability | 0.001 g / 0.01 g |
| Stabilization Time | ≤1 s |
| Display | High-contrast fluorescent LCD |
| Interface | RS-232C, USB (driver-free), Ethernet |
| Compliance | GLP, GMP, GCP, ISO 9001 |
| Power | AC adapter + built-in rechargeable battery |
| Features | Auto-calibration, ACAI (Automatic Counting Accuracy Improvement), animal weighing, parts counting, statistical analysis, comparison mode, underhook weighing, data storage |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | FX-iWP Series |
| Capacity Range | 122 g to 3200 g |
| Readability | 0.001 g (up to 320 g), 0.01 g (1220 g and above) |
| Pan Diameter | Ø130 mm (models ≤320 g), Ø150 mm (models ≥1220 g) |
| Stabilization Time | ≤1 s |
| Protection Rating | IP65 |
| Sensor Type | SHS (Super Hybrid Sensor) |
| Display | Large fluorescent LCD |
| Power | Rechargeable internal battery + AC adapter |
| Compliance | GLP/GMP/GCP/ISO data traceability support |
| Features | Auto-counting with ACAI, animal weighing, below-balance weighing, % weighing, statistical functions, overload protection with shock absorption, programmable buzzer alerts, auto power-off (10 min inactivity) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Precision Balance |
| Model | FZ-200i |
| Maximum Capacity | 520 g |
| Readability | 0.001 g |
| Repeatability | ≤ ±0.001 g |
| Calibration | Internal motorized calibration with built-in weight |
| Stabilization Time | ≤ 1 s |
| Dimensions (W × D × H) | 193 × 262.5 × 85.5 mm |
| Net Weight | ~3.0 kg |
| Power Supply | AC adapter or rechargeable Li-ion battery |
| Compliance | GLP, GMP, GCP, ISO/IEC 17025 compatible |
| Key Features | SHS high-speed sensor, B5 footprint, fluorescent LCD display, below-balance weighing hook, ACIA counting accuracy enhancement, auto-on/auto-off, response indicator, unit conversion, statistical counting, comparator mode, animal weighing mode |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Internal Calibration Precision Balance |
| Model | FZ-300iWP |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Stabilization Time | ~1 s |
| Pan Diameter | Ø130 mm |
| Dimensions (W×D×H) | 193 × 262.5 × 85.5 mm |
| Protection Rating | IP65 |
| Interface | RS-232 (standard), USB (driver-free), optional Ethernet |
| Software | WinCT-Plus (standard), GLP/GMP-compliant data export |
| Compliance | ISO/IEC 17025 traceable calibration, ASTM E1234, USP <41> & <1251>, FDA 21 CFR Part 11 ready (with audit trail enabled) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GF-200 / GF-300 / GF-2000 / GF-3000 |
| Capacity | 210 g / 310 g / 2100 g / 3100 g |
| Readability | 0.001 g (GF-200, GF-300) / 0.01 g (GF-2000, GF-3000) |
| Stabilization Time | ≤1 s |
| Display | High-brightness fluorescent display |
| Protection Rating | IP54 |
| Interface | RS-232C standard |
| Software | WinCT v3.x for data logging and GLP/GMP compliance |
| Internal Calibration | Auto-recalibration triggered by temperature drift or relocation |
| Weighing Modes | Standard weighing, counting, percentage, animal weighing, density (optional), comparison |
| Data Storage | 40 weight records + 20 unit-weight entries (counting mode) |
| Interval Logging | Configurable from 2 s to 10 min |
| Standards Compliance | GLP, GMP, GCP, ISO/IEC 17025 (applicable procedures), FDA 21 CFR Part 11 (via WinCT audit trail) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GF Series |
| Capacity Range | 210 g to 8100 g |
| Readability | 0.001 g to 0.1 g |
| Pan Size | 128 × 128 mm or 165 × 165 mm |
| Dimensions (W×D×H) | 210 × 317 × 86 mm |
| Weight | 4.6 kg to 5.1 kg |
| Display | High-contrast fluorescent LCD |
| Environmental Rating | IP54 |
| Interface | RS-232 standard |
| Compliance | GLP/GMP support, audit-ready data output |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Type | Precision Balance |
| Maximum Capacity | 420 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Precision Balance |
| Model | GF-8K |
| Maximum Capacity | 8000 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Calibration | Internal |
| Protection Rating | IP65 |
| Compliance | GLP, GMP, ISO/IEC 17025, USP <41>, ASTM E898 |
| Interface | RS-232C |
| Software | WinCT v3.x (included) |
| Operating Environment | 10–40 °C, 20–80% RH (non-condensing) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Precision Balance |
| Maximum Capacity | 10200 g |
| Readability | 0.1 g |
| Repeatability | 0.1 g |
| Calibration | Manual |
| Interface | Dual RS-232C and USB |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Optional Features | Density determination kit, below-balance weighing hook, flow rate display (FRD), impact shock detection (ISD), automatic minimum weight assessment (APA), auto environmental compensation (GX-A models), user permission management (up to 11 users), internal rechargeable battery (optional), control I/O modules (optional) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Internal Calibration Precision Balance |
| Maximum Capacity | 32.2 kg |
| Readability | 0.1 g |
| Repeatability | 0.1 g |
| Stabilization Time | ~1.5 s |
| Protection Rating | IP65 |
| Pan Material | SUS316 Stainless Steel |
| Interface | Dual RS-232C + USB |
| Data Storage | 200 weighing records / 50 unit mass sets / 50 calibration logs / 20 tare values / 20 upper/lower limit sets |
| Compliance | GLP/GMP/GCP/ISO-compliant report output |
| Optional Features | Animal Weighing, Dynamic Flow Rate Display (FRD), Impact Sensing Detection (ISD), Automatic Minimum Weight Verification (APA), Underhook Weighing, Comparison Mode, User Access Control |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Precision Balance |
| Max Capacity | 6200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Protection Rating | IP65 |
| Pan Material | SUS316 Stainless Steel |
| Stabilization Time | ~1 s |
| Interface | Dual RS-232C + USB |
| Compliance | GLP/GMP/GCP/ISO Data Output |
| Optional | Internal Rechargeable Battery, Control Output Modules, Bottom Hook |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Product Type | Imported Ultra-Micro Balance |
| Model | GH-202 |
| Maximum Capacity | 220 g / 51 g (dual-range) |
| Readability | 0.1 mg / 0.01 mg |
| Repeatability | ≤ ±0.1 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Pan Diameter | 90 mm |
| Compliance | GLP, GMP, GCP, ISO/IEC 17025, FDA 21 CFR Part 11 (audit trail capable via RS-232C interface) |
| Interface | Standard RS-232C port with WinCT-ROM software support |
| Power | Auto-on upon power application |
| Data Logging | Date/time-stamped weight, calibration event, user ID, and serial number storage |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GP-12K / GP-20K / GP-30K |
| Capacity | 12 kg / 20 kg / 30 kg |
| Readability | 0.1 g |
| Construction | Aluminum alloy housing + stainless steel pan |
| Display | Blue fluorescent VFD |
| Auto-calibration | Internal motorized weights |
| Environmental rating | IP65 (base unit) |
| Interface | RS-232C standard |
| Compliance | GLP, GMP, GCP, ISO 9001, ISO/IEC 17025 |
| Data storage | 200 weighing records, 100 timestamped entries, 20 tare values, 50 GLP-compliant logs (date/time, calibration ID, serial number), 50 unit weights for counting, 20 high/low limit sets |
| Stabilization time | ≤1.5 s |
| Weighing units | g, kg, lb, oz, ct, pcs, %, etc. |
| Auto-zero & auto-off | Yes |
| Output options | Comparator (3-level), analog output (optional) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GR-120 |
| Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 0.2 mg |
| Calibration | Internal motorized calibration with built-in reference weights |
| Compliance | GLP/GMP/ISO-compliant data output |
| Connectivity | RS-232C interface with Win-CT software |
| Weighing Units | 13 selectable units + counting, % weighing, density determination (with optional AD-1653 kit) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GR-200 |
| Maximum Capacity | 210 g |
| Readability | 0.1 mg |
| Repeatability | ≤ ±0.1 mg |
| Calibration | Internal Automatic Calibration with Motorized Weights |
| Environmental Compensation | Auto temperature & humidity drift correction |
| Interface | RS-232C serial port |
| Compliance | GLP, GMP, ISO/IEC 17025-ready |
| Software | WinCT v3.0 (included) |
| Optional Accessory | AD-1653 Density Measurement Kit |