| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GR-200 |
| Readability | 0.1 mg |
| Max Capacity | 210 g |
| Repeatability | ±0.2 mg |
| Calibration | Internal motorized calibration with built-in reference weights |
| Compliance | GLP/GMP/ISO 9001-ready |
| Interface | RS-232C |
| Software | Win-CT (included) |
| Weighing Units | 13 selectable units + counting, % weighing, density determination (with optional AD-1653 kit) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GR-202 |
| Type | Analytical Balance |
| Maximum Capacity | 42 g / 210 g |
| Readability | 0.01 mg / 0.1 mg |
| Repeatability | ±0.03 mg / ±0.2 mg |
| Calibration | Internal motorized calibration with built-in reference weights |
| Compliance | GLP, GMP, ISO 9001, ISO/IEC 17025 applicable |
| Interface | RS-232C serial port |
| Software | Win-CT (included) for data export to Excel, Word, and statistical analysis |
| Optional Accessory | AD-1653 Density Determination Kit |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GR-300 |
| Maximum Capacity | 310 g |
| Readability | 0.1 mg |
| Repeatability | ±0.2 mg |
| Weighing Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 249 × 330 × 328 mm |
| Weight | ~6.0 kg |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GX Series |
| Weighing Capacity Range | 210 g to 8100 g |
| Readability | 0.001 g / 0.01 g / 0.1 g |
| Repeatability | ±0.001 g / ±0.01 g / ±0.1 g |
| Linearity Error | ±0.002 g to ±0.03 g |
| Pan Size | 128 × 128 mm or 165 × 165 mm |
| Dimensions (W×D×H) | 210 × 317 × 86 mm |
| Weight | ~4.0–4.5 kg |
| IP Rating | IP54 |
| Display | High-contrast fluorescent LCD |
| Internal Calibration | Motor-driven automatic calibration with built-in weights |
| Connectivity | RS-232C interface, Win-CT software compatibility |
| Compliance | GLP, GMP, GCP, ISO standards |
| Data Storage | Up to 40 weighing records + 20 unit weight entries in counting mode |
| Auto-Power-Off | After 10 min idle |
| Weighing Modes | Standard weighing, counting, percentage, animal weighing, density (optional), comparison |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Internal Calibration Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Stabilization Time | ~1.5 s |
| Pan Size | Ø90 mm |
| Dimensions (W×D×H) | 259 × 358 × 332 mm |
| Interface | Dual RS-232C and USB |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Static Elimination | Built-in high-speed electrostatic discharger (2× faster than conventional units) |
| Environmental Compensation | Auto-self-calibration triggered by temperature drift |
| Software Features | ISD (Impact Sensing & Detection), APA (Automatic Minimum Weight Assessment), FRD (Flow Rate Display), User Permission Management (up to 11 accounts) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Internal Calibration Precision Balance |
| Model | GX203A |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Interface | Dual RS-232C and USB-B (simultaneous bidirectional communication) |
| Compliance | GLP/GMP/GCP-compliant data output, ISO/IEC 17025 traceable operation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Precision Balance |
| Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Internal Calibration | Automatic (built-in motorized calibration weight) |
| Stabilization Time | ≤1.0 s (typical), 0.8 s with ≥5 g load |
| Protection Rating | IP65 |
| Pan Material | SUS316 Stainless Steel |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Interface | Dual RS-232C and USB (simultaneous operation) |
| Compliance | GLP/GMP/GCP/ISO-compliant data output, FDA 21 CFR Part 11–ready audit trail support (via optional software) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Internal Calibration Precision Balance |
| Maximum Capacity | 32.2 kg |
| Readability | 0.1 g |
| Repeatability | 0.1 g |
| Stabilization Time | ~1.5 s |
| Protection Rating | IP65 |
| Pan Material | SUS316 Stainless Steel |
| Interface | Dual RS-232C + USB |
| Compliance | GLP/GMP/GCP/ISO Data Output Format |
| Weighing Modes | Standard, Animal Weighing, Checkweighing, Flow Rate Display (FRD), Lower/Upper Limit Comparison |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | HL-100 / HL-200 / HL-400 / HL-2000 / HL-4000 |
| Capacity | 100 g to 4000 g |
| Readability | 0.01 g to 1 g |
| Pan Size | Ø70 mm or 136 × 136 mm |
| Display | 7-digit, 12 mm high LCD |
| Power | Rechargeable battery or AC adapter (optional) |
| Battery Life | ~200 hours |
| IP Rating | IP65 (HL-WP models) |
| Housing | Stainless steel arc-shaped enclosure |
| Weight | ~500 g |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | HR Series |
| Capacity | 120 g / 210 g / 310 g |
| Readability | 0.1 mg |
| Repeatability | 0.1–0.2 mg |
| Linearity | ±0.2–±0.3 mg |
| Pan Diameter | 85 mm / 90 mm |
| Dimensions (W×D×H) | 213×319×301 mm / 217×429×316 mm |
| Weight | 6.0–8.0 kg |
| GLP/GMP/ISO Compliance | Yes |
| Interface Options | RS-232C |
| Optional | Rechargeable Battery (up to 10 h operation) |
| Units | 13 selectable weight units + counting + % mode |
| ACAI Function | Yes |
| Auto External Calibration | Single-key activated |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HR-250A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 252 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Calibration Method | External Calibration |
| Stabilization Time | 2 s |
| Display | Backlit LCD with 14 Weighing Units |
| Connectivity | RS-232C standard, USB (optional), Ethernet with Win-Plus (optional) |
| Power | AC adapter or rechargeable battery (optional) |
| Compliance | GLP/GMP/GCP/ISO-compliant data reporting |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MC-1000 / MC-6100 / MC-10K / MC-30K |
| Readability | 0.0001 g to 0.01 g |
| Capacity | 1.1 kg to 31 kg |
| Repeatability | 0.0005 g to 0.015 g |
| Linearity | ±0.002 g to ±0.2 g |
| Sensitivity Drift | ±2 ppm/°C to ±3 ppm/°C |
| Pan Size | 128×128 mm to 270×210 mm |
| Calibration | Internal motorized calibration with built-in weights |
| Stabilization Time | 1.5 s |
| Compliance | OIML R111 Class F1, GLP/GMP/GCP, ISO/IEC 17025 applicable procedures |
| Interface | RS-232C, USB (MC-1000/MC-6100), optional analog voltage output, current loop, comparator output with buzzer |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Product Type | Imported Precision Balance |
| Model | SK-1000WP |
| Max Capacity | 1000 g |
| Readability | 0.5 g |
| Repeatability | ±0.5 g |
| Calibration | External |
| Protection Rating | IP65 |
| Power Supply | 6 × D-cell batteries (approx. 200 h operation) or optional AC adapter |
| Display | High-contrast LCD with stability indicator, net weight mode, and low-battery warning |
| Construction | Stainless steel arched housing and weighing pan |
| Compliance | Designed for GLP/GMP environments requiring washdown-capable instrumentation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4212A |
| Readability | 0.1 mg (high-sensitivity mode), 1 mg (standard mode) |
| Response Time | 0.8 s (1 mg), 1.1 s (0.1 mg) |
| Interface | RS-232C standard, optional Ethernet (AD-4212A-08), BCD output (AD-4212A-01), external trigger input |
| Output Signals | Three-level comparator (HI / OK / LO) with audible buzzer alarm |
| Power Management | Auto-on / auto-off function |
| Mechanical Options | Stainless steel draft shield (AD-4212A-19), metal leveling feet (AD-4212A-20), 3 m extension cable (AD-4212A-07) |
| Sensor Technology | SHS (Super Hybrid Sensor) |
| Separated Design | Weighing unit and display unit connected via detachable cable (standard 2 m, extendable up to 5 m) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Calibration | Internal Automatic Calibration |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Display | 5-inch full-color capacitive touchscreen (BH-T series) |
| Draft Shield | Motorized auto-sensing infrared door with seamless flush design |
| Electrostatic Control | External DC ionizer (optional, BH-T model) |
| Weighing Pan | Perforated anti-convection pan (φ90 mm) |
| Stabilization Time | ≤3 s |
| Operating Environment | 15–30 °C, 20–80% RH (non-condensing) |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Features | Built-in daily/periodic performance verification, minimum weight auto-detection per USP <41> & ChP 2025, user-defined print formats, audit trail, role-based access control |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GR-300 / GR-202 / GR-200 / GR-120 |
| Capacity | 120–310 g |
| Readability | 0.01–0.1 mg |
| Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 249 × 330 × 328 mm |
| Weight | ~6.0 kg |
| Calibration | Internal motorized砝码, one-touch auto-calibration |
| Environmental Compensation | Automatic temperature & drift correction |
| Interface | RS-232 standard |
| Compliance | GLP, GMP, GCP, ISO/IEC 17025 |
| Software | WinCT Data Acquisition Suite |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | HW Series |
| IP Rating | IP65 |
| Display Type | LCD (HW-KGL) / Fluorescent (HW-KGV) |
| Weighing Range | 10 kg to 220 kg |
| Readability | 1 g to 20 g |
| Pan Dimensions | 250 × 250 mm to 390 × 530 mm |
| Dimensions (W×D×H) | 275 × 474 × 368 mm to 390 × 712 × 773 mm |
| Weight | 6 kg to 18 kg |
| Key Functions | High/Low Limit Checking, Batch Weighing, Tare, Preset Counting, Auto-Zero Tracking |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CQT-2601 |
| Instrument Type | Precision Balance |
| Maximum Capacity | 2600 g |
| Readability | 0.1 g |
| Repeatability | ±0.1 g |
| Linearity Error | ±0.2 g |
| Calibration Method | External Calibration |
| Calibration Weight Required | 2000 g |
| Display | 6-digit, 15 mm high backlit LCD |
| Stabilization Time | 3 s |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 12 V AC @ 150 mA adapter or 6 × AA batteries (optional) |
| Weighing Units | kg, g, lb, oz, ct, dr, GN |
| Pan Diameter | 145 mm |
| Draft Shield Dimensions (L×W×H) | 180 × 158 × 82 mm |
| Housing Material | Matte-finish ABS |
| Overall Dimensions (L×W×H) | 195 × 240 × 70 mm |
| Shock Protection | ShockProtect™ technology (withstands up to 180 kg overload) |
| Security | Bottom-mounted Kensington lock slot |
| Protection Class | IP42-rated enclosure (dust and splash resistant) |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EAB Series |
| Instrument Type | Analytical Balance |
| Capacity Range | 200–500 g |
| Readability | 0.01 mg / 0.1 mg |
| Maximum Capacity | 510 g |
| Repeatability | 0.02 mg |
| Calibration | Fully Automatic Internal Calibration and Optional External Calibration |
| Compliance | GLP-Compliant Data Logging, ISO/IEC 17025 Supportable, ASTM E898-22 Referenced Procedures |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CARRY CASE |
| Instrument Category | Accessory for Portable Balances |
| Compatible Models | ACBplus, AQT Series Portable Balances |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HCB 602H |
| Instrument Type | Precision Balance |
| Capacity | 600 g |
| Readability | 0.01 g |
| Repeatability (s.d.) | 0.002 g |
| Linearity Error | ±0.02 g |
| Pan Size | 120 mm diameter |
| Calibration Method | Internal HandiCal™ Auto-Calibration |
| Stabilization Time | ≤2 s |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 12 V DC, 800 mA (AC adapter included) |
| Display | 6-digit backlit LCD with capacity tracking bar |
| Connectivity | Dual RS-232 and USB interfaces |
| Construction | ABS plastic housing with stainless steel weighing pan |
| Dimensions (W×D×H) | 170 × 245 × 80 mm |
| Net Weight | 1.5 kg |
| Compliance | ISO/IEC 17025 compatible operation |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HCB1002 |
| Maximum Capacity | 1000 g |
| Readability | 0.01 g |
| Repeatability | 0.02 g |
| Calibration | Automatic Internal Calibration (HandiCal™) |
| Power Supply | Rechargeable Li-ion Battery & AC Adapter (12 VDC, 800 mA) |
| Interface | RS-232 and USB Bidirectional |
| Stabilization Time | ≤2 s |
| Operating Temperature | 0–40 °C |
| Display | 6-digit LCD with auto-backlight and capacity tracking bar |
| Pan Size | 120 mm Ø stainless steel |
| Dimensions (W×D×H) | 170 × 245 × 80 mm |
| Net Weight | 1.5 kg |
| Compliance | CE, UKCA, ISO/IEC 17025 traceable calibration support |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LPB |
| Instrument Type | Precision Balance |
| Capacity Range | 500–1000 g |
| Readability | 0.001 g |
| Calibration | Internal or External |
| Maximum Capacity | 820 g |
| Measurement Accuracy | 0.001 g |
| Repeatability | 0.002 g |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LTB |
| Instrument Type | Precision Balance |
| Capacity Range | 2000–5000 g |
| Maximum Capacity | 6000 g |
| Readability | 0.01 g |
| Calibration | Internal or External |
| Repeatability | 0.02 g |
| Linearity Error (±) | 0.03 g |
| Minimum Weight | 20 g |
| Stabilization Time | 2 s |
| Display | Backlit LCD with 24 mm high white digits on black background |
| Weighing Units | g, kg, ct, GN, N, dr, lb, oz, lb:oz, ozt, dwt, tl.T, tl.H, tl.S, T, Custom |
| Interface | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 185 × 185 mm |
| Dimensions (W × D × H) | 224 × 374 × 95 mm |
| Net Weight (Internal Calibration Models) | 5.9 kg |
| Net Weight (External Calibration Models) | 4.5 kg |
| Functions | Weighing, Piece Counting, Percentage Weighing, Checkweighing, Check Counting, Animal/Dynamic Weighing, Density Determination, Net/Gross Weighing, Display Hold, Peak Hold |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment Ltd. |
| Product Type | Imported Precision Balance |
| Model | LBB |
| Instrument Category | Precision Balance |
| Maximum Capacity | 15,000 g |
| Readability | 0.1 g |
| Calibration Method | External Calibration |
| Repeatability | 0.2 g |
| Linearity Error (±) | 0.3 g |
| Minimum Weight | 200 g |
| Stabilization Time | 2 s |
| Weighing Units | g, kg, ct, GN, N, dr, lb, oz, lb:oz, ozt, dwt, tl.T, tl.H, tl.S, T, Custom Units |
| Interfaces | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Display | Backlit LCD with 24 mm high white digits on black background |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 185 × 185 mm |
| Dimensions (W × D × H) | 224 × 374 × 95 mm |
| Net Weight | 4.5 kg |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment (UK) |
| Product Type | Analytical Balance |
| Model | LAB Series (e.g., LAB 214i, LAB 254e) |
| Maximum Capacity | 250 g |
| Readability | 0.0001 g |
| Repeatability | ±0.0002 g |
| Linearity Error | ±0.0003 g |
| Minimum Weight | 200 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (i-models) or External (e-models) |
| Display | Backlit LCD, 24 mm digit height |
| Weighing Units | g, mg, ct, GN, N, dr, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, user-defined |
| Interfaces | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 90 mm diameter |
| Draft Shield | Standard tempered glass square shield (192 × 195 × 230 mm W×D×H) |
| Dimensions (W×D×H) | 224 × 374 × 338 mm |
| Net Weight | 6.2 kg (i-models), 5.8 kg (e-models) |
| Compliance | GLP-compliant data logging, ISO/IEC 17025 support, USP Chapter 41 & 1251 compatible |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DDK |
| Instrument Type | Analytical Balance-Compatible Density Kit |
| Balance Compatibility | Adam NBL Series Balances Only |
| Maximum Load Capacity (with NBL balance) | 800 g |
| Mass Readability | 0.0001 g (0.1 mg) / 0.001 g (1 mg) |
| Repeatability | ±0.0001 g / ±0.001 g |
| Calibration | Internal Automatic or Manual Calibration Supported |
| Density Measurement Range | Solid & Liquid Samples |
| Measurement Principle | Archimedean Buoyancy Method (ASTM D792, ISO 1183, USP <841>) |
| Brand | Adam |
|---|---|
| Origin | UK |
| Manufacturer | Adam Equipment |
| Model | NBL / NBL-p |
| Capacity | 2000–5000 g (up to 32,000 g) |
| Readability | 0.1 g |
| Internal Resolution | 0.00001 g (10 µg) |
| Repeatability | ±0.2 g |
| Linearity Error | ±0.4 g |
| Operating Temperature | 0–40 °C |
| Power Supply | 12 V DC, 50/60 Hz, 800 mA |
| Display | Backlit LCD (digit height 20 mm) |
| Weighing Pan | 304 Stainless Steel (400 × 300 mm) |
| Dimensions (W×D×H) | 401 × 460 × 102 mm (base), column: 401 × 500 × 600 mm |
| Net Weight | 4.5–7.3 kg |
| Communication | USB + bidirectional RS-232 |
| Weighing Modes | Standard, Net/Gross, Checkweighing, Percentage, Piece Counting, Animal/Dynamic, Density, Below-Balance |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SAB |
| Instrument Type | Analytical Balance |
| Capacity Range | 200–500 g |
| Readability | 0.01 mg (10 µg) / 0.1 mg (100 µg) |
| Calibration | Internal Automatic Calibration & External Calibration |
| Maximum Capacity | 510 g |
| Repeatability | 0.02 mg |
| Display | 15 mm high graphic LCD |
| Interface | RS-232 |
| Operating Temperature | 10–30 °C |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Net Weight | 6.7–7.0 kg |
| Dimensions (W×D×H) | 224 × 374 × 338 mm |
| Pan Size | 80 mm diameter |
| Draft Shield | Standard glass square draft shield (192 × 195 × 230 mm) |
| Housing Material | ABS plastic |
| Compliance | GLP-compliant data logging, password protection, audit-ready timestamped output |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPB363i / SPB723i / SPB1203i / SPB2103i (Internal Calibration) / SPB363e / SPB723e (External Calibration) |
| Weighing Capacity | 360 g – 2100 g |
| Readability | 0.001 g |
| Repeatability | ±0.002 g |
| Linearity Error | ±0.003 g to ±0.005 g |
| Stabilization Time | ≤3 s |
| Calibration | Internal (i-series) or External (e-series) |
| Display | 15-mm-high graphical LCD |
| Pan Size | 110 mm diameter |
| Draft Shield | Standard tempered glass square shield (192 × 195 × 115 mm, W×D×H) |
| Housing Material | ABS plastic |
| Dimensions (W×D×H) | 224 × 374 × 219 mm |
| Net Weight | 6.4 kg (i-series), 6.7 kg (e-series) |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Operating Temperature | 10 °C – 30 °C |
| Connectivity | RS-232 |
| Weighing Units | g, mg, ct, GN, lb, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, user-defined |
| Compliance | GLP-compliant data logging (date/time stamp), password protection, audit-ready operation |