Balance
Filter
Showing 61–90 of 367 results
| Brand | Adam |
|---|---|
| Origin | UK |
| Manufacturer | Adam Equipment |
| Type | Precision Balance |
| Model | STB |
| Capacity | 3200–8200 g |
| Readability | 0.01 g |
| Repeatability | ±0.02 g |
| Linearity Error | ±0.03–0.04 g |
| Stabilization Time | 3 s |
| Calibration | Internal (i-models) or External (e-models) |
| Display | 15 mm high graphical LCD |
| Weighing Units | g, mg, ct, GN, lb, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, custom |
| Interface | RS-232 |
| Operating Temperature | 10–30 °C |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Pan Size | 185 × 185 mm |
| Dimensions (W×D×H) | 224 × 374 × 95 mm |
| Net Weight | 6.4 kg (i), 6.7 kg (e) |
| Construction | ABS housing, 304 stainless steel pan |
| Compliance | GLP-compliant data logging, password protection, audit-ready timestamped printouts |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-20 |
| Type | Ultra-Micro Balance |
| Maximum Capacity | 22 g |
| Readability | 1 µg (0.001 mg) |
| Repeatability | 0.0025 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Sample Pan | Perforated mesh design |
| Draft Shield | Conductive-coated glass with lateral sliding door |
| Interfaces | RS-232C and USB |
| Data Storage | 200 measurement records + 50 calibration logs |
| Software | WinCT-Balance (A&D certified, GLP/GMP-compliant) |
| Display | High-contrast white-backlit LCD |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-22 |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 22 g |
| Dual Range | 5–20 g |
| Readability | 0.1 µg (10⁻⁷ g) |
| Repeatability | 0.004 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Communication Interfaces | RS-232C and USB |
| Data Storage | 200 measurement records + 50 calibration logs |
| Software | WinCT-Balance (GLP/GMP-compliant reporting) |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-5 |
| Type | Ultra-Micro Balance |
| Capacity | 5.2 g |
| Readability | 0.001 mg (1 µg) |
| Repeatability | ±0.0012 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Weighing Pan | Perforated mesh pan |
| Draft Shield | Conductive-coated glass with lateral sliding door |
| Interfaces | RS-232C and USB |
| Data Storage | 200 weighing records + 50 calibration logs |
| Software | WinCT (A&D proprietary GLP/GMP-compliant data acquisition and reporting suite) |
| Display | Large high-contrast white-backlit LCD |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-10001A |
| Maximum Capacity | 10200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Capacity Range | >5000 g |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-10002A |
| Maximum Capacity | 10200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Capacity Range | >5000 g |
| Accuracy Class | 0.01 g (100 mg) |
| Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, JIS B 7721, ASTM E898 |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-1003A |
| Type | Precision Balance |
| Maximum Capacity | 1100 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-2002A |
| Maximum Capacity | 2200 g |
| Readability | 0.01 g |
| Repeatability | ±0.01 g |
| Calibration | External |
| Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready data logging |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-203A |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Balance Type | Precision Top-Loading Balance |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-3002A |
| Type | Precision Balance |
| Maximum Capacity | 3200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Weighing Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Stabilization Time | ~1.0 s (at 50 g load) |
| Compliance | ISO 9001, JIS B 7721, ASTM E898 |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-303A |
| Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-4002A |
| Maximum Capacity | 4200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Pan Size | 165 × 165 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, ISO/IEC 17025 compatible workflows, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6001A |
| Maximum Capacity | 6200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6002A |
| Maximum Capacity | 6200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-ready, GLP/GMP-supportive architecture |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-603A |
| Maximum Capacity | 620 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Brand | Axel Semrau |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CHRONECT XPR |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | RSD ≤ ±10% at 1 mg |
| Calibration | Fully Automatic |
| Sample Throughput | Up to 32 powder samples and 6 liquid reagents per run |
| Environmental Operation | Inert gas-compatible (N₂/Ar), glovebox-integrated |
| Compliance | Designed for GLP/GMP environments with audit trail support |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 2-5750-01 |
| Type | Mechanical Dual-Pan Centrifuge Tube Balancing Scale |
| Max. Tube Diameter | Ø35 mm |
| Pan Opening Diameter | Ø36 mm |
| Balance Base Material | Stainless Steel (SUS304) |
| Stand Material | PVC |
| Tube Holder Material | PMMA (Polymethyl Methacrylate) |
| Holder Dimensions | Ø50 × 86 mm |
| Net Weight | 820 g |
| Overall Dimensions (L×W×H) | 311 × 100 × 230 mm |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory balance verification workflows |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES-J120D |
| Instrument Type | Density-Specific Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Density Resolution | 0.0001 g/cm³ |
| Weighing Chamber Height | 210 mm |
| Pan Diameter | Φ90 mm |
| Operating Temperature Range | 13–25 °C |
| Operating Humidity Range | 20–85% RH (non-condensing) |
| Stabilization Time (Avg.) | ≤2.5 s |
| Warm-up Time | 30–60 min |
| Power Supply | 220 V AC / 50 Hz input |
| RS232 Baud Rates | 300, 600, 1200, 2400, 4800, 9600 |
| Construction | Stainless Steel Density Accessories |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM D792, ISO 1183, and USP <841> density determination protocols |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Model | ES1035A |
| Max Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability | ±0.02 mg |
| Linearity | ±0.02 mg |
| Calibration | Automatic Internal Calibration |
| Stabilization Time | ≤2.5 s |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–80 %RH |
| Pan Diameter | Ø90 mm |
| Chamber Height | 230 mm |
| Display | Adjustable LCD (185 × 100 mm) |
| Interface | RS232 (300–9600 bps) |
| Power | 220 V AC / 50 Hz input |
| Accuracy Class | Class I (per OIML R76) |
| Brand | D&T |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP1204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability (5% load) | ±0.2 mg |
| Repeatability (near full load) | ±0.3 mg |
| Linearity Error | ±0.3 mg |
| Calibration Method | Internal (isoCAL) |
| Stabilization Time | ≤3 s |
| Pan Diameter | Φ90 mm |
| Dimensions (W×D×H) | 210 × 310 × 315 mm |
| Draft Shield Height | 210 mm |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Temperature Drift | ≤5 ppm/°C |
| Warm-up Time | <15 min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| DC Output | 12 VDC, 1 A |
| Communication Interface | RS232 (configurable baud rates: 300–9600) |
| Display | VA LCD |
| Environmental Compensation | Automatic temperature & time-triggered isoCAL |
| Shock Protection | Four-stage damping system |
| Accuracy Class | ISO 9001-compliant design |
| Brand | D&TC Dantec |
|---|---|
| Origin | Tianjin, China |
| Model | ES1200 |
| Maximum Capacity | 1200 g |
| Readability | 10 mg |
| Repeatability | ±10 mg |
| Linearity Error | ±10 mg |
| Stabilization Time | ≤2.5 s |
| Pan Diameter | Φ160 mm |
| Dimensions (W×D×H) | 210 × 310 × 90 mm |
| Operating Temperature | 13–25 °C |
| Operating Humidity | 10–70 % RH |
| Warm-up Time | 30–60 min |
| Power Input | 220 V AC / 50 Hz |
| Output | 7.5 V DC / 600 mA |
| RS232 Baud Rates | 300–9600 |
| Accuracy Class | Class II |
| Sensor Type | Gold-plated ceramic variable-capacitance transducer |
| Environmental Compensation | Integrated high-precision humidity & temperature sensors |
| Display | Backlit LCD with intuitive layout |
| Weighing Units | g, ct, oz, lb, etc. |
| Modes | Standard weighing, counting, percentage, checkweighing |
| Construction | Corrosion-resistant stainless-steel pan |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | XE2.7S |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 2.1 g |
| Readability | 0.1 µg |
| Accuracy Class | Class I (per EU Directive 2014/31/EU) |
| Verification Scale Interval (e) | 1 µg |
| Minimum Weight (USP <41>) | 0.82 mg (recommended), 1.3 mg (typical) |
| Sensitivity Drift | 5 ppm/K (10–30 °C) |
| Tare Range | <100% of max capacity |
| Calibration | Internal (IsoCAL™ automatic temperature- and time-controlled calibration) |
| Stabilization Time | 8 s (typical) |
| Measurement Time | 12 s (typical) |
| Pan Diameter | Ø30 mm |
| Chamber Height | 80 mm |
| Dimensions (L×W×H) | 90 mm × 295 mm × 150 mm |
| Net Weight | ~4.7 kg |
| Operating Environment | 18–23 °C, 50–75% RH, temp. drift ≤1 °C/h |
| Power Supply | 100–240 VAC, 50/60 Hz, 0.5–1.0 A |
| Compliance | FDA 21 CFR Part 11 (ALCOA+ principles), GLP/GMP data integrity, OIML R111-1 E1 external calibration standard |
| Brand | D&T Corp |
|---|---|
| Origin | Tianjin, China |
| Model | ES8K |
| Maximum Capacity | 8000 g |
| Readability | 0.1 g |
| Repeatability | ±0.2 g |
| Linearity Error | ±0.2 g |
| Operating Temperature | 13–25 °C |
| Operating Humidity | 10–70 % RH |
| Response Time (avg.) | ≤2.5 s |
| Display Size | 185 × 100 mm |
| Pan Size | 370 × 310 mm |
| Dimensions (W×D×H) | 370 × 310 × 140 mm |
| Warm-up Time | 30–60 min |
| Power Supply | AC 220 V / 50 Hz → DC 7.5 V / 600 mA |
| Accuracy Class | Class II |
| Sensor Type | Gold-plated ceramic variable-capacitance transducer |
| Environmental Compensation | Integrated high-precision humidity & temperature sensors |
| Communication Interface | RS232 bidirectional |
| Weighing Modes | Standard, Piece Counting, Percentage, Checkweighing |
| Units | g, ct, oz, dwt |
| Construction | Anti-static, corrosion-resistant, spill-proof stainless steel pan and reinforced streamlined chassis |
| Brand | Dante / D&T |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES-LMZ |
| Instrument Type | Precision Laboratory Balance for Coal Testing |
| Readability | 0.01 mg to 10 mg (model-dependent) |
| Calibration | isoCAL Fully Automatic Internal Calibration |
| Repeatability | 0.04 mg (at 5% load, ES-L55-MZ) |
| Sensitivity Drift | 5 ppm/K (10–30 °C) |
| Stabilization Time | ≤2.5 s |
| Weighing Pan Diameter | Φ48 mm (standard) or custom |
| Dimensions | 227.17 × 144.5 × 94.2 mm |
| Power Input | DC 24 V ±10%, 0.1 A |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 30–85% RH |
| Interface | RS232 / RS485 |
| Communication Protocols | DAT232, DAT485 (MODBUS-compatible), customizable |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | VLF Series |
| Type | Analytical Balance |
| Capacity | 100 g / 120 g / 200 g / 220 g |
| Readability | 0.1 mg |
| Calibration | External (VLF-E models) or Internal (VLF-C models) |
| Stabilization Time | ≤2 s (fast mode) or ≤4 s (precision mode) |
| Pan Diameter | Φ85 mm |
| Dimensions (W×D×H) | 350 × 210 × 346 mm |
| Display | LED, with real-time ambient temperature indication |
| Leveling | Front-mounted bubble level |
| Interface | RS232C serial port |
| Data Management | Local storage & recall, PC connectivity via dedicated software, optional Bluetooth printer support |
| Weighing Modes | Standard weighing, counting, percentage, density (indirect), animal/weighing-in-motion (via software extension) |
| Units | g, mg, oz, ct, lb, etc. |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model Series | VLP |
| Instrument Type | Analytical Balance |
| Capacity Range | 20–6000 g |
| Readability | 10 mg / 100 mg / 1 g (model-dependent) |
| Calibration | External |
| Dimensions (W×D×H) | 270 × 190 × 110 mm |
| Pan Diameter | Ø130 mm or Ø160 mm (model-dependent) |
| Compliance | ISO 9001-manufactured |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | VLS-2204A |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg (adjustable to 1 mg / 0.01 g / 0.1 g / 1 g) |
| Repeatability | ±0.1 mg |
| Linearity Error | ±0.2 mg |
| Accuracy Class | Class I (per OIML R76) |
| Stabilization Time | 2 s (fast) or 4 s (slow) |
| Pan Diameter | Ø85 mm |
| Net Weight | 7.8 kg |
| Dimensions (W×D×H) | 365 × 215 × 330 mm |
| Calibration | Internal |
| Power Supply | 220 V / 50 Hz |
| Communication Interfaces | Bluetooth 5.0, USB Type-A, RS-232, IoT platform API support |
| Brand | INNOTEG |
|---|---|
| Origin | Imported |
| Manufacturer Type | Direct Manufacturer |
| Model | IB / IBE |
| Instrument Type | Analytical Balance |
| Capacity | 122 g / 220 g / 320 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Minimum Weight (USP) | 120 mg / 3.0 mg / 5.0 mg |
| Linearity Error | ±0.2 mg / ±0.2 mg / ±0.3 mg |
| Stabilization Time | ~1.5 s (IB), ~2.0 s (IBE) |
| Calibration | Internal Automatic Calibration (IB) / External Calibration (IBE) |
| Pan Diameter | Ø90 mm |
| Dimensions (W×D×H) | 258 × 357 × 331 mm |
| Interface | Dual RS-232C + USB |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Optional | Density kit, below-balance weighing hook, rechargeable battery, control I/O modules |
| Brand | Longteng |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES Series |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Instrument Type | Precision Mass Comparator |
| Maximum Capacity | 5,000 g |
| Readability | 0.01 g |
| Repeatability | ≤ ±0.01 g |
| Calibration Method | Automatic Internal Calibration |
| Pan Dimensions | Up to 340 × 300 mm |
| External Dimensions | Up to 460 × 315 × 160 mm |
| Compliance | Meets JJG 99-2006 (Chinese National Verification Regulation for Weights), ISO/IEC 17025 traceable operation |
| Brand | Longteng |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES Series Standard |
| Instrument Type | Platform Balance |
| Maximum Capacity | Up to 600 kg |
| Readability | 0.5 g to 200 g (model-dependent) |
| Calibration Method | Manual |
| Repeatability | ≤ ±2 g |
| Sensor Technology | Strain Gauge |
| Power Supply | AC/DC with Built-in Rechargeable Battery |
| Connectivity | RS-232 Interface for PC Data Transfer |