Empowering Scientific Discovery

Beijing Angke Huisheng Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAlioth-π
Price RangeUSD 4,200 – 5,600 (FOB)
Detection Limit (Pb in aqueous matrix)<0.3 mg/L
Detection Limit (Cd in aqueous matrix)<0.5 mg/L
Measurement Time60 s per analysis
Detector Resolution≤145 eV (Mn Kα)
X-ray TubeTransmission-target microfocus tube
Optical PathOptimized 3D ultra-short path (sample–tube–detector) with multilayer scatter suppression coating
CameraIntegrated 1-MP visible-light imager with real-time video capture
Enclosure RatingIP67-equivalent dual-layer liquid ingress protection
Housing MaterialAerospace-grade Al-Mg alloy
Software AlgorithmHolographic Fundamental Parameters (FP) quantification engine
Operating ModePC-controlled or standalone tablet interface
Warm-up Time<3 s
Power SupplyRechargeable Li-ion battery (8+ hrs continuous operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelMERAK-LEII
Detection RangeNa–Ti (extendable to C, N, O, F)
Light Element LLDsS ≤ 0.2 ppm, Cl ≤ 0.1 ppm, Si ≤ 0.8 ppm
ExcitationMonochromatized Wavelength-Selective X-ray Beam via Focusing Polycapillary Optics
Optical ArchitectureFixed X-Ray Path System (XFS)
Sample FormSolid, Liquid, or Powder in Disposable Cups/Membranes
ComplianceDesigned for ASTM D2622, D4294, D7039, ISO 8754, IP 287, and USP <233> elemental impurity testing workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHMET Automated Enrichment System
Price RangeUSD 7,000 – 14,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelMERAK-MINI
Detection Limit (S)0.5 ppm (300 s)
Detection Limit (Cl)0.3 ppm (300 s)
Quantification Range0.5 ppm – 5%
Analysis Time60–300 s
RepeatabilityRSD ≤ 3% @ 10 ppm S, RSD ≤ 1.5% @ 1000 ppm S
Dimensions350 mm × 230 mm × 370 mm
Weight12.5 kg
Power Consumption80 W
Operating Temperature5–40 °C
Battery Life>4 h
ComplianceASTM D7039, ASTM D7536, ISO 20884, ISO 15597
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelDUBHE-1710
Detection Limit (Cl)0.1 ppm
Measurement Range0.1 ppm – 5 wt%
Analysis Time60–300 s
Repeatability≤0.2 ppm (at 1 ppm Cl), ≤0.5 ppm (at 5 ppm Cl), ≤2.5 ppm (at 50 ppm Cl)
Sample Prep Time<10 s
Operating Warm-up≤10 min
Cost per Sample<USD 0.55 (excl. labor)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelMERAK-SC
ExcitationMonochromatic Focused X-ray (Johansson-type DCC crystal)
DetectionUltra-thin Graphene-window Silicon Drift Detector (SDD)
Elemental RangeF–Cl (light elements), K–Zn (transition metals)
LOD (F)0.15 wt% (300 s, aqueous matrix)
LOD (Al–Cl)0.0002–0.005 wt% (300 s)
Sample TypesLiquids, powders, solids
GeometryTop-illumination
Sample RotationMotorized, software-controlled
Temperature Control24 ± 0.3 °C
Analysis Time30–300 s per sample
Stability< ±3% intensity drift over 24 h
Quantification EngineFast FP 2.0 fundamental parameters software
ComplianceDesigned for ISO 8258 (control charts), ASTM E1621 (ED-XRF for cement), USP <233> (elemental impurities), and GLP/GMP-aligned data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelPHECDA-FVS
Instrument TypeMicro-Zone ED-XRF
Elemental RangeMg to U
Detection Limits (Large Spot Mode, Light Matrix)S: 10 mg/kg, Fe: 2 mg/kg, Pb: 1.0 mg/kg, Cd: 0.3 mg/kg
Minimum Focal Spotφ200 µm
Spot Size OptionsSoftware-Selectable Apertures (φ200–φ5000 µm, Rectangular Beam Optional)
X-Y Stage Range±10 mm
Step Resolution10 µm
Camera Magnification10×–100×
Sample Chamber Dimensions280 × 230 × 70 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelMERAK-CEMII
Price RangeUSD 70,000 – 140,000
ComplianceGB/T 176–2008
Elements AnalyzedNa, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn
Detection PrincipleWavelength-Dispersive XRF (WDXRF) with High-Flux Doubly Curved Crystal Spectrometer (HF DCCS) and Secondary Target Excitation
Sample FormSolid powders (pressed pellets or fused beads)
Vacuum/AtmosphereAmbient air operation (no vacuum pump or He purge required)
CoolingPeltier-cooled detector (no liquid nitrogen)
StabilityReady for measurement within 3 minutes after power-on
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelPHECDA-HE & PHECDA-HES
Detection Limit (soil matrix, 300 s)Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg
Repeatability (Cd, soil)RSD < 15% at 0.3 mg/kg
Elemental RangeMg–U
Sample TypesSolid, liquid, powder, viscous
DetectorHigh-performance Silicon Drift Detector (SDD)
Excitation PrincipleMonochromatic focused excitation via doubly curved crystal (DCC)
SoftwareFast FP® 2.0 quantitative engine
Auto-sampler30+ positions (PHECDA-HES)
HMET® integration for aqueous samples (detection limit1–3 µg/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMERAK-TINY
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelMEGREZ-A
ExcitationDual X-ray tube sources with polycapillary-focusing monochromators
Detection PrincipleEnergy-dispersive X-ray fluorescence (ED-XRF) with monochromatic excitation
Elemental RangeZ ≥ 5 (Boron and heavier elements)
Detection Limit (Heavy Metals)As low as 0.05 mg/kg (matrix-dependent)
Quantification MethodFast fundamental parameters (FP) algorithm with minimal or zero calibration standards
ComplianceDesigned for ISO 8258, ASTM E1621, and GB/T 30091–2013 compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelDUBHE-1610
Detection Limit (LLD)0.4 ppm (S)
Measurement Range0.4 ppm – 5 wt%
Analysis Time60–300 s
Repeatability≤0.2 ppm (at 2 ppm S), ≤0.5 ppm (at 10 ppm S), ≤2.5 ppm (at 50 ppm S)
Excitation LineCr Kα (5.41 keV)
Optical ConfigurationDual Polycapillary Focusing Monochromator + Full-Focus Bent Crystal Analyzer
Sample PreparationESP (Easy Sample Prepare) System
Operating ModeBenchtop, Air-path, No Gas or Solvent Consumption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelPHECDA-ECO
Element RangeMg–U
LOD (soil matrix, 600 s)Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg
Repeatability (Cd, soil)≤0.3 mg/kg, RSD <15%
Sample TypesSolid, liquid, powder, viscous
DetectorHigh-performance Silicon Drift Detector (SDD)
ExcitationMonochromatic focused excitation via doubly curved crystal (DCC)
MethodSingle-wavelength excitation + energy-dispersive detection
SoftwareFast FP® quantitative engine with matrix-adaptive modeling
Optional PreconcentrationHeavy Metal Enrichment Tape (HMET®) for aqueous samples (LOD: 1–3 µg/L)
Weight7.5 kg
Dimensions370 × 290 × 190 mm
OperationAmbient air, no vacuum/gas required
Sample InterfaceMotorized sample rotation stage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnchor Wisdom
OriginBeijing, China
ModelPHECDA-PRO
Excitation PrincipleMonochromatic Focused Excitation (using doubly curved crystal monochromator)
Detection PrincipleEnergy-Dispersive XRF (ED-XRF)
Elemental RangeMg–U
LOD (soil matrix, 600 s)Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg
Precision (RSD)Cd <15% at 0.3 mg/kg (soil, 600 s)
Sample TypesSolids, powders, slurries, liquids (with HMET® membrane enrichment), filters (e.g., PM₂.₅), and viscous matrices
DetectorHigh-performance silicon drift detector (SDD) with optimized active area and energy resolution
SoftwareFast FP® quantitative engine (fundamental parameters-based, matrix-adaptive, standard-free or minimal-standard calibration)
Optional EnhancementHeavy Metal Enrichment Technology (HMET®) for aqueous samples (LOD: 1–3 µg/L)
Portability8.7 kg
Show next