- All
- Favorite
- Popular
- Most rated
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSolar |
| Spectral Range | 300–2500 nm |
| Detector Type | Back-illuminated CCD & InGaAs array |
| Spectral Resolution | 0.5–20 nm (model-dependent) |
| Optical Dynamic Range | 3800:1 |
| Signal-to-Noise Ratio | 450:1 to 5000:1 (wavelength-dependent) |
| Stray Light | <0.3% to <0.5% |
| Wavelength Accuracy | ±0.3 nm (UV-VIS), ±1.5–3.0 nm (NIR-SWIR) |
| Pixel Resolution | 2048-pixel CCD (14 × 500 µm) / 256-pixel TE-cooled InGaAs |
| Integration Time | 2 µs – 20 s |
| Linearity | >99% (nonlinear calibration applied) |
| Calibration Traceability | NIM (National Institute of Metrology, China), U = 8.0% (k=2) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048CL-EVO |
| Spectral Range | 200–1100 nm |
| Detector | CMOS linear array (2048 pixels) |
| Optical Resolution (FWHM) | 0.06–20 nm (configuration-dependent) |
| Sensitivity | 375,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 300:1 |
| Dynamic Range | 4000:1 |
| Stray Light | 0.19–1.0% (grating-dependent) |
| AD Converter | 16-bit, 6 MHz |
| Integration Time | 9 µs – 59 s |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Sampling Speed | 0.38 ms/spectrum (USB3), 1.0 ms/spectrum (Ethernet) |
| I/O | HD-26 connector with 2 analog in/out, 13 digital I/O, trigger/sync/laser control |
| Power | USB 3.0 (500 mA) or 12 VDC (300 mA) |
| Dimensions & Weight | 177 × 127 × 44.5 mm, 1135 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaLight-XE-HP |
| Light Source Type | Pulsed Xenon Lamp |
| Spectral Output Range | 200–1000 nm |
| Pulse Energy | 39 mJ per flash |
| Average Optical Power | 6 W (pulsed) |
| Lifetime | >1 × 10⁹ flashes |
| Synchronization Interface | 9-pin D-sub, TTL-compatible |
| Electrical Requirements | 11–28 VDC, 2.08 A |
| Connector | SMA-905 |
| Dimensions | 98 × 44 × 35 mm |
| Weight | 192 g |
| Mounting | OEM-integrated design |
| Illumination Mode | External illumination |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HS2048XL-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 pixels) |
| Resolution (FWHM) | 1–20 nm (configuration-dependent) |
| Sensitivity | 1,250,000 counts/µW·ms |
| Signal-to-Noise Ratio | 525:1 |
| Stray Light | < 1% |
| Dynamic Range | 200–1160 nm |
| Numerical Aperture | 0.22 |
| Focal Length | 37.5 mm |
| Integration Time | 2 µs – 600 s |
| A/D Conversion | 16-bit, 1 MHz |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Data Acquisition Rate | 2.44 ms per scan (with on-board averaging) |
| Digital I/O | HD-26 connector with 2 analog inputs, 2 analog outputs, 3 digital inputs, 12 digital outputs, trigger & sync support |
| Power Supply | USB-powered (700 mA) or external 12 VDC (360 mA) |
| Dimensions & Weight | 175 × 165 × 85 mm, 1.95 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR256-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan (USB 3.0) |
| Integration Time | 10 µs – 500 ms |
| Detector | 256-pixel InGaAs linear array (50 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| Dynamic Range | 6000:1 (HS mode), 9000:1 (LN mode) |
| SNR | 1900:1 (HS), 5000:1 (LN) |
| Sensitivity | 8.2 × 10⁶ counts/µW·ms (HS, 1000–1750 nm) |
| ADC | 16-bit, 500 kHz |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft v8+ with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048x64TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 × 64 pixels) |
| Resolution (FWHM) | 0.09–20 nm (configurable via slit width & grating) |
| Sensitivity | 300,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 550:1 |
| Stray Light | <1% |
| Dark Noise Reduction | 2–3× via thermoelectric cooling |
| Cooling Delta | −35 °C relative to ambient |
| Integration Time | 9.7 ms – 500 s |
| A/D Converter | 16-bit, 500 kHz |
| Interface | USB 2.0 (480 Mbps) / RS-232 (115.2 kbps) |
| Optical Design | Symmetric Czerny-Turner, 75 mm focal length |
| Power Supply | 5 VDC, 3.0 A (instrument) |
| Dimensions & Weight | 250 × 179 × 144 mm, 3.6 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaRaman Bundles |
| Instrument Type | Portable Raman Spectrometer |
| Spectral Range | 100–3600 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Laser Excitation | 785 nm integrated |
| Detector Platform | AvaSpec-ULS2048x64TEC-EVO-RS or AvaSpec-ULS2048CL-EVO-RS (TE-cooled CCD) |
| Slit Options | 25 µm |
| Fiber Connector | FC/PC |
| Software | Panorama-Light with AvaRaman module |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & user access control enabled) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NIR256-1.7-HSC-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.13 ms/scan |
| Data Sampling Interval | 0.4 ms/scan |
| Measurement Mode | Transmission/Reflection |
| Optical Design | Symmetrical Czerny-Turner, 100 mm focal length, 1-stage TE-cooled |
| Detector | TE-cooled InGaAs linear array (256 × 50 µm × 500 µm) |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| AD Converter | 16-bit, 1.2 MHz |
| Integration Time (HS mode) | 20 µs – 500 ms |
| Integration Time (LN mode) | 20 µs – 20 s |
| Dynamic Range (HS/LN) | 4900:1 / 7600:1 |
| SNR (HS/LN) | 1900:1 / 5000:1 |
| Gain Modes | High Sensitivity (HS) and Low Noise (LN) |
| Grating Options | Four selectable, exchangeable gratings |
| Slit Options | Interchangeable slits (25–500 µm) |
| Digital I/O | HD-26 connector with 13 bidirectional digital I/O lines, 2 analog inputs/outputs, trigger/sync/gate/laser control |
| Operating Temperature | 0–40 °C |
| Cooling | ΔT = 24 °C below ambient |
| Dimensions & Weight | 185 × 160 × 184 mm, 3.6 kg |
| Software | AvaSoft suite with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | VARIUS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (VARIUS™ 2K) / 365:1 (VARIUS™ 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR-Mini |
| Spectral Range | 900–1750 nm |
| Detector | InGaAs (256-pixel array) |
| Optical Resolution | 6 nm (typical, slit- and grating-dependent) |
| Sensitivity (HS mode) | 665,000 counts/µW/ms (integrated over 1000–1750 nm) |
| Signal-to-Noise Ratio (HS) | 1900:1 |
| Dynamic Range (HS) | 4750:1 |
| Stray Light | <1% |
| A/D Converter | 16-bit, 500 kHz |
| Integration Time (HS) | 10 µs – 300 ms |
| Interface | USB 2.0 (480 Mbps), fiber-coupled input, 50 cm integrated cable |
| Dimensions | 95 × 68 × 20 mm |
| Weight | 185 g |
| Operating Temperature | 0–55 °C |
| Software Compatibility | AvaSoft v8+, Windows/Linux DLL support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048x64-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 × 64 pixels, 0.89 mm height) |
| Optical Resolution | 0.09–20 nm (configuration-dependent) |
| Sensitivity | 650,000 counts/µW per millisecond |
| Signal-to-Noise Ratio | 450:1 |
| Stray Light | <1% |
| AD Converter | 16-bit, 1.33 MHz |
| Integration Time | 2.4 ms – 25 s |
| Read Noise | 7.5 counts RMS |
| Data Transfer Rate | 2.44 ms/scan (USB 3.0) |
| Interface | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (885 mA) or 12 VDC (420 mA) |
| Dimensions & Weight | 175 × 127 × 44.5 mm, 1180 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaLight-LED |
| Light Source Type | High-Stability LED Array |
| Illumination Mode | External Illumination |
| Connector | SMA 905 |
| Power Supply | 12 VDC, 40 mA |
| Dimensions & Weight | 175 × 110 × 44 mm, 480 g |
| Spectral Options | 355/380 nm, 400/410/430 nm, 450/470/490 nm, 530/590/780 nm |
| FWHM | 11–30 nm (model-dependent) |
| Output Power (into 600 µm fiber) | 10–25 µW |
| Control Interface | TTL-compatible pulse modulation via IC-DB26-2 cable (optional, for synchronization with AvaSpec-USB2 spectrometers) |
| Compliance | CE, RoHS |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR512-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan |
| Data Sampling Interval | 0.53 ms/scan |
| Detector | 512-pixel InGaAs linear array (25 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| AD Converter | 16-bit, 500 kHz |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| Integration Time | 10 µs – 10 s |
| Dynamic Range | up to 9000:1 (LN mode) |
| SNR | up to 5000:1 (LN mode) |
| Trigger & I/O | HD-26 connector with 13 digital I/O lines, 2 analog in/out, TTL trigger, sync, strobe, laser control |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft suite with chemometrics support |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & user access control enabled) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NEXOS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (NEXOS™, 2K) / 365:1 (PNEXOS™, 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Communication Interfaces | USB (NEXOS™), RS232/SPI (NEXOS™ Link), Optical Bench Only (NEXOS™ Bench Only) |
| Optical Design | Symmetric Czerny-Turner |
| Pixel Options | 2048 or 4096 |
| Slit Options | Configurable slit widths |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HSC1024x58TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD |
| Resolution (FWHM) | 0.2–7 nm (configurable) |
| Sensitivity | 445,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 1200:1 |
| Dynamic Range | 40,000 |
| Stray Light | 0.5% |
| Optical Platform | Symmetrical Czerny-Turner, f = 100 mm, NA = 0.13 |
| Cooling | Single-stage thermoelectric (TEC) |
| ADC | 16-bit, 250 kHz |
| Integration Time | 5.2 ms – 60 min |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 I/O connector |
| Dimensions | 185 × 161 × 185 mm |
| Weight | 3500 g |
Show next