Empowering Scientific Discovery

Beijing Handasen Mechanical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelS60
Instrument TypeAutomatic Quantitative Concentrator
Temperature RangeAmbient to 99°C
Temperature Control Accuracy±0.5°C
Sample Volume Capacity0–60 mL
Heating MethodWater Bath (Manufactured in Singapore)
Power Rating800 W
Gas Flow Rate0–8 L/min
Compatible Tube Sizes1.5 mL to 50 mL
Application FieldsEnvironmental (EPA), Pharmaceutical (FDA, USP), Clinical (CDC), Food Safety, Academic Research, and Chemical Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAurora
OriginCanada
ModelVERSA 110
Plate Positions8
Pipetting PrecisionCV <5% at 1 µL
Pipetting Range30 nL – 1000 µL
Channel ConfigurationSingle-channel
Dimensions (W×D×H)45 × 57 × 54 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelSPE360/SPE330/SPE200
Automation LevelFully Automatic
Channel Count6 (SPE360), Multi-Channel (SPE330), Dual-Channel (SPE200)
Extraction TypeCartridge-Based SPE
Flow Rate Control0.1–60 mL/min
Solvent Types Supported6 (SPE360), 8 (SPE330 & SPE200)
Sample Capacity36 samples (SPE360), 6 samples (SPE330), 2 samples (SPE200)
Sample Load Volume10–20,000 mL (SPE360/SPE330), 1–1,000 mL (SPE200)
Solvent-Wetted MaterialsPTFE
Volumetric Accuracy±1.0% (system), ±1.5% (peristaltic pump)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelRS27/KS27
Operating Temperature (Continuous)-20°C to 170°C (Ex model: ≤60°C)
Operating Temperature (Short-term)up to 200°C (Ex model: ≤60°C)
Mounting Vessel Diameter26–28 mm
Housing MaterialPEI (Polyetherimide)
Standard Cable Length7 m (optional: 20 m)
ATEX CertificationII 2G Ex ia IIB T4 Gb (SP13ATEX3645X)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelCCS15.75-25
Material (Wetted Parts)316L Stainless Steel (EN 1.4404)
ConnectionTri-Clamp 25 mm
Operating Temperature0–100 °C (continuous), –20 to 130 °C (SIP, 500 h cumulative)
Pressure Rating1 MPa (10 bar g) at rated temperature
IP RatingIP67
Surface Roughness (Ra)<0.375 µm (<15 µin)
Detectable Bubble Size≥2 mm
ComplianceEN 10204 3.1B Certificate Available
Cable LengthStandard 7 m (optional 20 m / 40 m)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelAPS6-25
Housing MaterialPolypropylene
Inner Diameter6 mm
Outer Diameter49 mm
Tri-Clamp Connection25 mm
Cable LengthStandard (no extension specified)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelSAC4.5-25
Tubing IDØ4.5 mm
Tubing ODØ38 mm
Clamp Connection25 mm (DIN 11851 / ISO 2852)
Standard Cable Length7 m
Housing MaterialASTM A276 Type 316L Stainless Steel
ComplianceDesigned for GMP-compliant biopharmaceutical fluid paths
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelFCP4-25
Housing MaterialPolypropylene (PP)
Inner DiameterØ4 mm
Outer DiameterØ40 mm
Clamp Connection25 mm
Standard Cable Length5 m
ComplianceDesigned for hygienic applications in regulated industries
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelCCS9.4-25
Housing Material316L Stainless Steel
Inner Diameter9.4 mm
Outer Diameter51 mm
Tri-Clamp Connection25 mm
Cable Length7 m
Operating PrincipleUltrasonic Transit-Time Differential Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
Housing Material316L Stainless Steel
Tube ID15.75 mm
Tube OD51 mm
Tri-Clamp Size25 mm
Output InterfaceAnalog/RS485 (via external ultrasonic controller)
Operating PrincipleTransmission-mode ultrasonic detection of gas voids and particulates in flowing liquid streams
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelFCS10-25
Inner Diameter10.0 mm
Outer Diameter51 mm
Tri-Clamp Connection25 mm
Standard Cable Length5 m
Optional Cable Length25 m
Housing MaterialASTM A276 Type 316L Stainless Steel
ComplianceFDA-compliant wetted surfaces, EHEDG-certified hygienic design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelLS85
Operating Temperature (Continuous)−15 °C to 60 °C (Ex model: max 60 °C)
Operating Temperature (Short-term)up to 130 °C (Ex model: max 60 °C)
Vessel Diameter Range79–91 mm
Standard Cable Length7 m
Optional Cable Length20 m
ATEX CertificationII 2G Ex ia IIB T4 Gb (SP13ATEX3645X)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQ M-Tech
OriginSweden
ModelPAC4-25
Inner Diameter4 mm
Outer Diameter50 mm
Tri-Clamp Connection25 mm
Standard Cable Length7 m (optional: 20 m or 40 m)
Housing MaterialPolypropylene (PP)
ComplianceCE, RoHS, FDA-compliant for food-contact applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena / biometra
OriginGermany
ModelqTOWER³ auto 84
Instrument TypeGradient Real-Time PCR System
Sample Capacity384-well
Heating Rate3.7 °C/s
Temperature Accuracy±0.1 °C
Dimensions (W × D × H)310 × 365 × 479 mm
Block MaterialAnodized Aluminum Alloy
Recommended Sample Volume2–30 µL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAHN
OriginGermany
Product Type12-Channel Electronic Pipette
Volume Range30–300 µL
Accuracy±0.9–5.0%
Precision (CV)≤0.5%
SterilizationAutoclavable Lower Tip Assembly
CompatibilityUniversal Fit for Standard Conical Tips (ISO 8655-compliant)
Channel Count12
Power SourceRechargeable Li-ion Battery (≥10,000 operations per charge)
DisplayBacklit OLED with Multilingual UI (EN/DE/FR/ES)
ComplianceISO 8655-2:2022, ISO 8655-6:2022, CE, RoHS, IEC 61000-4-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAHN
OriginGermany
TypeSingle-Channel Manual Pipette
Volume Range0.1 µL – 10 mL
Accuracy±0.3% to ±12% (volume-dependent)
Precision (CV)≤0.15% to ≤6.0%
SterilizationAutoclavable at 121°C, 20 min
ComplianceISO 8655-2:2022, EN ISO 13485 certified
Chemical ResistanceHigh (PP, PTFE, stainless steel components)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAHN
OriginGermany
ModelAHN myDpette
Instrument TypeManual Bottle Top Dispenser
Volume Range5.0–50.0 mL
Minimum Increment0.25 mL
Accuracy±2%
Chemical ResistanceHigh (PTFE, FEP, ETFE, PPS components)
ComplianceISO 8536-4, DIN EN ISO 8655-7, GLP-ready design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAHN
OriginGermany
Product TypeManual Multichannel Pipette
Channel Count8 or 12
Volume Range30–300 µL
Accuracy (at nominal volume)±0.75–1.50%
Precision (CV)≤0.25–0.75%
SterilizationAutoclavable (121 °C, 20 min)
Volume Adjustment MechanismCounter-locked digital dial
Tip CompatibilityUniversal low-retention filtered tips (ISO 8655-compliant)
Color-Coded Volume IndicatorsYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAHN
OriginGermany
TypeSingle-Channel Electronic Pipette
Volume Range0.2–5000 µL
Accuracy (Max Error)0.1–5.0%
Precision (CV)0.1–3.0%
Increment Resolution0.01–5.0 µL
MotorBrushless DC, Maintenance-Free
ComplianceISO 8655-2:2022, EN ISO 9001, CE Marked
Software InterfaceUSB-C for Firmware Updates & Parameter Backup
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelELMA S 30 H
Instrument TypeDedicated Benchtop Ultrasonic Cleaner
Tank Capacity2.75 L
Ultrasonic Frequencies37 kHz / 80 kHz (Dual-Frequency Operation)
Ultrasonic Power Output100 W (Adjustable Range: 40–100% in 10% increments)
Heating Temperature Range30–80 °C (Adjustable in 1 °C steps)
Timer Range1–30 min (Predefined presets: 1, 2, 3, 4, 5, 10, 15, 20, 25, 30 min
Sound-Dampening LidIntegrated Acoustic Lid with Safety Interlock
Drain & FillAutomatic Drain Valve with Optional Fill Function
Sweep Frequency ModeEnabled via Dedicated Toggle
Degassing ModeManual & Auto-Activated (10-min timed cycle, triggered by ≥2 s press during sonication)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSystec
OriginGermany
ModelD-Series
Instrument TypeBenchtop Sterilizer
Max Temperature140 °C
Max Pressure4 bar
Chamber Dimensions500 × 750 mm (D-150/D-200)
External Dimensions850 × 730 × 1300 mm
Chamber Volume200 L (D-200)
Power SupplyD-45: 220–240 V, 50/60 Hz, 16 A
D-65 to D-200380–400 V, 50/60 Hz, 16 A
ConstructionFully stainless steel (AISI 304) chamber, outer casing and support frame
Control SystemMicroprocessor-based with LCD interface, 25 programmable cycles (DX), 12 (DE), or 4 (DB)
Data LoggingUp to 500 sterilization cycles stored internally
ConnectivityRS-232 and RS-485 ports for network integration
Safety ComplianceEN 285, EN 61010-1, PED 2014/68/EU, CE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMiltenyi Biotec
OriginGermany
ModelautoMACS® Pro
Automation LevelFully Automatic
Sample ThroughputUp to 6 × 5 mL, 5 × 15 mL, or 3 × 50 mL tubes per run
Max Total Cells per Sample4 × 10⁹
Max Magnetically Labeled Cells per Sample2 × 10⁸
Sample Volume Range0.2–50 mL
Compatible Starting MaterialsWhole blood, PBMCs, bone marrow, dissociated tissues, tumor digests, cultured cells (primary & cell lines)
Species CompatibilityHuman, mouse, rat, non-human primates, and others via indirect MicroBeads
Column TypesReusable autoMACS Columns (single or dual configuration)
Separation ModesPositive selection, untouched isolation, depletion
Regulatory ComplianceDesigned for GLP-compliant workflows
Dimensions (w × d × h)605 × 343 × 392.5–454 mm (with MiniSampler: 605 × 455 × 392.5–454 mm)
Cooling SystemIntegrated Chill Racks (2–8 °C sample/ reagent storage)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginGermany
ModelTC-650
Temperature Range (TC-650AP)–20 °C to +200 °C
Temperature Range (TC-650SD)–20 °C to +170 °C
Temperature Range (TC-650MX)–20 °C to +135 °C
Temperature Stability±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX)
Bath Capacity7.0 L
Pump Flow Rate16 L/min (AP), 11 L/min (SD), 12 L/min (MX)
Pump TypeAdjustable-speed (AP), 2-stage (SD), 1-stage (MX)
Internal Dimensions (W×D×H)157 × 142 × 127 mm
External Dimensions (W×D×H)540 × 220 × 617 mm (AP/SD), 540 × 220 × 645 mm (MX)
Weight45 kg (AP/SD), 42 kg (MX)
Power SupplyVoltage and frequency specified at order
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0