- All
- Favorite
- Popular
- Most rated
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | S60 |
| Instrument Type | Automatic Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–60 mL |
| Heating Method | Water Bath (Manufactured in Singapore) |
| Power Rating | 800 W |
| Gas Flow Rate | 0–8 L/min |
| Compatible Tube Sizes | 1.5 mL to 50 mL |
| Application Fields | Environmental (EPA), Pharmaceutical (FDA, USP), Clinical (CDC), Food Safety, Academic Research, and Chemical Analysis |
| Brand | Aurora |
|---|---|
| Origin | Canada |
| Model | VERSA 110 |
| Plate Positions | 8 |
| Pipetting Precision | CV <5% at 1 µL |
| Pipetting Range | 30 nL – 1000 µL |
| Channel Configuration | Single-channel |
| Dimensions (W×D×H) | 45 × 57 × 54 cm |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | SPE360/SPE330/SPE200 |
| Automation Level | Fully Automatic |
| Channel Count | 6 (SPE360), Multi-Channel (SPE330), Dual-Channel (SPE200) |
| Extraction Type | Cartridge-Based SPE |
| Flow Rate Control | 0.1–60 mL/min |
| Solvent Types Supported | 6 (SPE360), 8 (SPE330 & SPE200) |
| Sample Capacity | 36 samples (SPE360), 6 samples (SPE330), 2 samples (SPE200) |
| Sample Load Volume | 10–20,000 mL (SPE360/SPE330), 1–1,000 mL (SPE200) |
| Solvent-Wetted Materials | PTFE |
| Volumetric Accuracy | ±1.0% (system), ±1.5% (peristaltic pump) |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | RS27/KS27 |
| Operating Temperature (Continuous) | -20°C to 170°C (Ex model: ≤60°C) |
| Operating Temperature (Short-term) | up to 200°C (Ex model: ≤60°C) |
| Mounting Vessel Diameter | 26–28 mm |
| Housing Material | PEI (Polyetherimide) |
| Standard Cable Length | 7 m (optional: 20 m) |
| ATEX Certification | II 2G Ex ia IIB T4 Gb (SP13ATEX3645X) |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | CCS15.75-25 |
| Material (Wetted Parts) | 316L Stainless Steel (EN 1.4404) |
| Connection | Tri-Clamp 25 mm |
| Operating Temperature | 0–100 °C (continuous), –20 to 130 °C (SIP, 500 h cumulative) |
| Pressure Rating | 1 MPa (10 bar g) at rated temperature |
| IP Rating | IP67 |
| Surface Roughness (Ra) | <0.375 µm (<15 µin) |
| Detectable Bubble Size | ≥2 mm |
| Compliance | EN 10204 3.1B Certificate Available |
| Cable Length | Standard 7 m (optional 20 m / 40 m) |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | APS6-25 |
| Housing Material | Polypropylene |
| Inner Diameter | 6 mm |
| Outer Diameter | 49 mm |
| Tri-Clamp Connection | 25 mm |
| Cable Length | Standard (no extension specified) |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | SAC4.5-25 |
| Tubing ID | Ø4.5 mm |
| Tubing OD | Ø38 mm |
| Clamp Connection | 25 mm (DIN 11851 / ISO 2852) |
| Standard Cable Length | 7 m |
| Housing Material | ASTM A276 Type 316L Stainless Steel |
| Compliance | Designed for GMP-compliant biopharmaceutical fluid paths |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | FCP4-25 |
| Housing Material | Polypropylene (PP) |
| Inner Diameter | Ø4 mm |
| Outer Diameter | Ø40 mm |
| Clamp Connection | 25 mm |
| Standard Cable Length | 5 m |
| Compliance | Designed for hygienic applications in regulated industries |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | CCS9.4-25 |
| Housing Material | 316L Stainless Steel |
| Inner Diameter | 9.4 mm |
| Outer Diameter | 51 mm |
| Tri-Clamp Connection | 25 mm |
| Cable Length | 7 m |
| Operating Principle | Ultrasonic Transit-Time Differential Detection |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Housing Material | 316L Stainless Steel |
| Tube ID | 15.75 mm |
| Tube OD | 51 mm |
| Tri-Clamp Size | 25 mm |
| Output Interface | Analog/RS485 (via external ultrasonic controller) |
| Operating Principle | Transmission-mode ultrasonic detection of gas voids and particulates in flowing liquid streams |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | FCS10-25 |
| Inner Diameter | 10.0 mm |
| Outer Diameter | 51 mm |
| Tri-Clamp Connection | 25 mm |
| Standard Cable Length | 5 m |
| Optional Cable Length | 25 m |
| Housing Material | ASTM A276 Type 316L Stainless Steel |
| Compliance | FDA-compliant wetted surfaces, EHEDG-certified hygienic design |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | LS85 |
| Operating Temperature (Continuous) | −15 °C to 60 °C (Ex model: max 60 °C) |
| Operating Temperature (Short-term) | up to 130 °C (Ex model: max 60 °C) |
| Vessel Diameter Range | 79–91 mm |
| Standard Cable Length | 7 m |
| Optional Cable Length | 20 m |
| ATEX Certification | II 2G Ex ia IIB T4 Gb (SP13ATEX3645X) |
| Brand | AQ M-Tech |
|---|---|
| Origin | Sweden |
| Model | PAC4-25 |
| Inner Diameter | 4 mm |
| Outer Diameter | 50 mm |
| Tri-Clamp Connection | 25 mm |
| Standard Cable Length | 7 m (optional: 20 m or 40 m) |
| Housing Material | Polypropylene (PP) |
| Compliance | CE, RoHS, FDA-compliant for food-contact applications |
| Brand | Analytik Jena / biometra |
|---|---|
| Origin | Germany |
| Model | qTOWER³ auto 84 |
| Instrument Type | Gradient Real-Time PCR System |
| Sample Capacity | 384-well |
| Heating Rate | 3.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Dimensions (W × D × H) | 310 × 365 × 479 mm |
| Block Material | Anodized Aluminum Alloy |
| Recommended Sample Volume | 2–30 µL |
| Brand | AHN |
|---|---|
| Origin | Germany |
| Product Type | 12-Channel Electronic Pipette |
| Volume Range | 30–300 µL |
| Accuracy | ±0.9–5.0% |
| Precision (CV) | ≤0.5% |
| Sterilization | Autoclavable Lower Tip Assembly |
| Compatibility | Universal Fit for Standard Conical Tips (ISO 8655-compliant) |
| Channel Count | 12 |
| Power Source | Rechargeable Li-ion Battery (≥10,000 operations per charge) |
| Display | Backlit OLED with Multilingual UI (EN/DE/FR/ES) |
| Compliance | ISO 8655-2:2022, ISO 8655-6:2022, CE, RoHS, IEC 61000-4-2 |
| Brand | AHN |
|---|---|
| Origin | Germany |
| Type | Single-Channel Manual Pipette |
| Volume Range | 0.1 µL – 10 mL |
| Accuracy | ±0.3% to ±12% (volume-dependent) |
| Precision (CV) | ≤0.15% to ≤6.0% |
| Sterilization | Autoclavable at 121°C, 20 min |
| Compliance | ISO 8655-2:2022, EN ISO 13485 certified |
| Chemical Resistance | High (PP, PTFE, stainless steel components) |
| Brand | AHN |
|---|---|
| Origin | Germany |
| Model | AHN myDpette |
| Instrument Type | Manual Bottle Top Dispenser |
| Volume Range | 5.0–50.0 mL |
| Minimum Increment | 0.25 mL |
| Accuracy | ±2% |
| Chemical Resistance | High (PTFE, FEP, ETFE, PPS components) |
| Compliance | ISO 8536-4, DIN EN ISO 8655-7, GLP-ready design |
| Brand | AHN |
|---|---|
| Origin | Germany |
| Product Type | Manual Multichannel Pipette |
| Channel Count | 8 or 12 |
| Volume Range | 30–300 µL |
| Accuracy (at nominal volume) | ±0.75–1.50% |
| Precision (CV) | ≤0.25–0.75% |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Volume Adjustment Mechanism | Counter-locked digital dial |
| Tip Compatibility | Universal low-retention filtered tips (ISO 8655-compliant) |
| Color-Coded Volume Indicators | Yes |
| Brand | AHN |
|---|---|
| Origin | Germany |
| Type | Single-Channel Electronic Pipette |
| Volume Range | 0.2–5000 µL |
| Accuracy (Max Error) | 0.1–5.0% |
| Precision (CV) | 0.1–3.0% |
| Increment Resolution | 0.01–5.0 µL |
| Motor | Brushless DC, Maintenance-Free |
| Compliance | ISO 8655-2:2022, EN ISO 9001, CE Marked |
| Software Interface | USB-C for Firmware Updates & Parameter Backup |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ELMA S 30 H |
| Instrument Type | Dedicated Benchtop Ultrasonic Cleaner |
| Tank Capacity | 2.75 L |
| Ultrasonic Frequencies | 37 kHz / 80 kHz (Dual-Frequency Operation) |
| Ultrasonic Power Output | 100 W (Adjustable Range: 40–100% in 10% increments) |
| Heating Temperature Range | 30–80 °C (Adjustable in 1 °C steps) |
| Timer Range | 1–30 min (Predefined presets: 1, 2, 3, 4, 5, 10, 15, 20, 25, 30 min |
| Sound-Dampening Lid | Integrated Acoustic Lid with Safety Interlock |
| Drain & Fill | Automatic Drain Valve with Optional Fill Function |
| Sweep Frequency Mode | Enabled via Dedicated Toggle |
| Degassing Mode | Manual & Auto-Activated (10-min timed cycle, triggered by ≥2 s press during sonication) |
| Brand | Systec |
|---|---|
| Origin | Germany |
| Model | D-Series |
| Instrument Type | Benchtop Sterilizer |
| Max Temperature | 140 °C |
| Max Pressure | 4 bar |
| Chamber Dimensions | 500 × 750 mm (D-150/D-200) |
| External Dimensions | 850 × 730 × 1300 mm |
| Chamber Volume | 200 L (D-200) |
| Power Supply | D-45: 220–240 V, 50/60 Hz, 16 A |
| D-65 to D-200 | 380–400 V, 50/60 Hz, 16 A |
| Construction | Fully stainless steel (AISI 304) chamber, outer casing and support frame |
| Control System | Microprocessor-based with LCD interface, 25 programmable cycles (DX), 12 (DE), or 4 (DB) |
| Data Logging | Up to 500 sterilization cycles stored internally |
| Connectivity | RS-232 and RS-485 ports for network integration |
| Safety Compliance | EN 285, EN 61010-1, PED 2014/68/EU, CE-marked |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Model | autoMACS® Pro |
| Automation Level | Fully Automatic |
| Sample Throughput | Up to 6 × 5 mL, 5 × 15 mL, or 3 × 50 mL tubes per run |
| Max Total Cells per Sample | 4 × 10⁹ |
| Max Magnetically Labeled Cells per Sample | 2 × 10⁸ |
| Sample Volume Range | 0.2–50 mL |
| Compatible Starting Materials | Whole blood, PBMCs, bone marrow, dissociated tissues, tumor digests, cultured cells (primary & cell lines) |
| Species Compatibility | Human, mouse, rat, non-human primates, and others via indirect MicroBeads |
| Column Types | Reusable autoMACS Columns (single or dual configuration) |
| Separation Modes | Positive selection, untouched isolation, depletion |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Dimensions (w × d × h) | 605 × 343 × 392.5–454 mm (with MiniSampler: 605 × 455 × 392.5–454 mm) |
| Cooling System | Integrated Chill Racks (2–8 °C sample/ reagent storage) |
| Brand | Brookfield |
|---|---|
| Origin | Germany |
| Model | TC-650 |
| Temperature Range (TC-650AP) | –20 °C to +200 °C |
| Temperature Range (TC-650SD) | –20 °C to +170 °C |
| Temperature Range (TC-650MX) | –20 °C to +135 °C |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Bath Capacity | 7.0 L |
| Pump Flow Rate | 16 L/min (AP), 11 L/min (SD), 12 L/min (MX) |
| Pump Type | Adjustable-speed (AP), 2-stage (SD), 1-stage (MX) |
| Internal Dimensions (W×D×H) | 157 × 142 × 127 mm |
| External Dimensions (W×D×H) | 540 × 220 × 617 mm (AP/SD), 540 × 220 × 645 mm (MX) |
| Weight | 45 kg (AP/SD), 42 kg (MX) |
| Power Supply | Voltage and frequency specified at order |
Show next