| Brand | AECC (Aviation Industry Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Model | JB1010 |
| Instrument Type | Single-Channel Electric Pipette |
| Automation Level | Motorized |
| Volume Range | 1–99 mL per dispense (programmable in 0.01 mL increments) |
| Maximum Capacity | 10 mL |
| Accuracy | ±0.01 mL |
| Repeatability (RSD) | <0.15% |
| Dimensions (L×W×H) | 200 × 210 × 260 mm |
| Weight | 2.3 kg |
| Power Input | 100–240 V AC, 50–60 Hz, 2.5 A |
| Output Voltage | 24 V DC, 5 A |
| Power Consumption | 120 W |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–80% RH |
| Chemical Compatibility | Neutral and acidic aqueous solutions |
| Regulatory Compliance | Supplied with calibration certificate and metrological verification report |
| Brand | AECC (Aviation Engine Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-3010 |
| Instrument Type | Single-Channel Electric Pipette |
| Automation Level | Motorized Precision Spiking System |
| Channel Count | 1 |
| Volume Range | Customizable (250–1000 µL) |
| Minimum Dispense Volume | 25 µL (at 250 µL range) |
| Dispensing Accuracy (Relative Error) | ≤ ±0.22% (typical, per JJG 646) |
| Dispensing Precision (CV) | ≤ 0.04% (typical, per JJG 646) |
| Syringe Material | Borosilicate Glass |
| Fluidic Path Material | PTFE |
| Priming Modes | Full-Range Aspiration / Volume-Specific Aspiration |
| Cleaning Modes | Multi-cycle Standard Wash / Low-Volume Sequential Wash |
| Compliance | Fully compliant with JJG 646–2018 “Verification Regulation for Pipettes” (China National Metrology Verification Regulation) |
| Brand | AECC (Aviation Industry Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Model | DR100 |
| Instrument Type | Single-Channel Electric Pipette |
| Automation Level | Motorized |
| Capacity Range | 0.5 g to 500 g (dependent on connected analytical balance) |
| Accuracy | ±0.03 g |
| Dimensions (L×W×H) | 140 mm × 180 mm × 360 mm |
| Weight | 4.4 kg |
| Power Input | 100–240 V AC, 50–60 Hz, 2.5 A |
| Output Voltage | 24 V DC, 5 A |
| Operating Temperature | 10–30 °C |
| Relative Humidity | 0–80 % RH |
| Compatible Liquids | Water and neutral aqueous solutions |
| Calibration | Supplied with certificate of conformity and traceable calibration report |
| Brand | AECC (Aviation Engine Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Model | LPG-2000 |
| Light Source | DC-pulsed hollow cathode discharge (low-pressure) |
| Optical Chamber | Evacuated vacuum chamber |
| Wavelength Range | 170–430 nm |
| Grating | Holographic concave grating, focal length 750 mm, 2400 grooves/mm |
| Spectral Resolution | < 0.024 nm |
| Detector | Hamamatsu high-sensitivity, low-noise photomultiplier tube (PMT) |
| Elemental Coverage | Ag, As, Au, B, Ba, Be, Bi, Ca, Cd, Ce, Cu, Ga, Ge, Hg, In, La, Mg, Mn, P, Pb, Pd, Pt, Rh, Ru, Sb, Se, Si, Sn, Sr, Te, Tl, Y, Zn, Zr (including sub-190 nm lines for B and P) |
| Detection Limits | 1×10⁻⁵% to 1×10⁻⁷% (e.g., Bi ≤ 0.00001%, As ≤ 0.0005%, P ≤ 0.001%, B ≤ 0.001%) |
| Precision | RSD < 20% for 10 replicate excitations on homogeneous samples |
| Temperature Control | Thermostabilized optical chamber, ±0.1 °C stability |
| Brand | AECC (Aviation Engine Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-2010 |
| Instrument Type | Single-Channel Electric Pipettor |
| Automation Level | Motorized Piston-Driven |
| Volume Range | Customizable (Standard Configurations: 5 mL, 10 mL, 25 mL) |
| Minimum Dispense Volume | 0.5 mL (at 5 mL total capacity), 1.0 mL (at 10 mL or 25 mL capacity) |
| Accuracy | ±0.01% (relative error, per JJG 646 verification data) |
| Dispense Modes | Full-range aspiration or volume-specific aspiration |
| Cleaning Modes | Multi-cycle standard wash / Low-volume multi-step wash (reagent-saving mode) |
| Syringe Material | Borosilicate glass |
| Fluidic Path Materials | PTFE tubing and fittings |
| Compliance | Fully compliant with JJG 646–2018 “Verification Regulation for Pipettes” (China National Metrology Technical Specification) |