Empowering Scientific Discovery

Beijing Jianling Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee Instruments
OriginUSA (Manufactured in Logan, UT)
ModelSI-111
Output TypeAnalog Voltage (Non-Amplified)
Field of View22°30′
Spectral Range8–14 µm
Measurement Range−60 °C to +110 °C
Calibration Uncertainty±0.2 °C (−20 °C to +65 °C)
Response Time (95%)0.6 s
Sensitivity60 µV/°C
Thermopile Output Range−3.3 mV to +3.3 mV
Thermistor Output Range0–2500 mV (excitation-dependent)
Excitation Voltage2500 mV (typ.)
Operating Environment−55 °C to +80 °C, 0–100% RH (non-condensing)
HousingMarine-grade stainless steel (IP68 connector at sensor head)
DimensionsØ23 mm × 60 mm
Mass190 g (incl. 5 m cable)
Cable5 m, 4-conductor, shielded twisted-pair, TPR jacket (UV-stable, hydrophobic, low-temp flexible)
Long-term Drift<2% per year (with clean germanium window)
Warranty4 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDeChem-Tech
OriginGermany
Instrument TypeDiscrete Analyzer (Flow-Based Spectrophotometric Analyzer)
ModelCleverChem F.U.V.
Wavelength Range200–850 nm
Sample Volume per Test10 mL
Reagent PositionsN/A (Reagent-free operation for core wine parameters)
Flow Cell Pathlength0.20 mm
Light SourceDeuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime)
FTIR Resolution< 0.4 cm⁻¹
UV-Vis Spectral Resolution0.25 nm
Detector2048-pixel CCD array (200 × 14 µm/pixel)
Temperature Control Range5–35 °C
Dimensions (Analyzer Unit)35 × 28 × 26 cm (W×D×H)
Weight10 kg
ComplianceDesigned for GLP-compliant wine laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRQflex 20
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEcomatik
OriginGermany
ModelSF-G
Measurement PrincipleGranier Thermal Dissipation Method
Probe ConfigurationDual-needle, Constant Current Heating
Output Signal0–1000 µV differential voltage
Power Consumption0.2 W ±5% (84 mA @ 12 VDC)
Operating Temperature–25 to +50 °C
Cable LengthStandard 5 m (extendable to 20 m)
Suitable Stem Diameter>5 cm
Probe VariantsSF-G33 (33 mm needle / 20 mm heater), SF-G43 (43 mm / 20 mm), SF-G63 (63 mm / 20 mm)
ComplianceCompatible with ISO 17025-accredited data acquisition systems and GLP/GMP environmental monitoring workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectrum Technologies
OriginUSA
Model3415F
Measurement Range0–1999 μmol·m⁻²·s⁻¹
Spectral Response400–700 nm (PAR)
Accuracy±5%
Display Unitμmol·m⁻²·s⁻¹
Power Supply9V alkaline battery
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare