- All
- Favorite
- Popular
- Most rated
| Brand | ATOMTEX |
|---|---|
| Model | AT1103M |
| Type | Portable Dose Rate Meter |
| Detector | Be-window NaI(Tl) Scintillator (Ø9×2 mm) |
| Measured Quantity | Ambient Dose Equivalent Rate H′(0.07) |
| Measurement Range | 50 nSv/h – 100 µSv/h |
| Energy Range | 5–160 keV |
| Energy Response | ±35% (5–60 keV), ±30% (60–160 keV) |
| Accuracy | ±15% (full range), ±5% (calibration sources: ⁵⁵Fe, ²⁴¹Am, ¹⁰⁹Cd, ⁵⁷Co) |
| Operating Temperature | 0–+40 °C |
| Relative Humidity | ≤90% at +35 °C |
| IP Rating | IP54 |
| Weight | 0.8 kg |
| Dimensions | 233×85×67 mm |
| Power | Rechargeable Ni-MH battery (6 V), AC 220 V / 50 Hz, DC 12 V |
| Battery Life | ≥24 h |
| Data Storage | 100 measurement records + 256-channel MCA spectrum storage |
| Compliance | IEC 60846, CISPR 22:1997, IEC 61000-4-2:1995, IEC 61000-4-3:1995 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Instrument Type | Portable |
| Measurement Range (Low) | 0–0.5 ppm |
| Detection Limit (Low) | 1 ppb |
| Response Time (Low) | < 95 s |
| Measurement Range (High) | 0–10.00 ppm |
| Resolution (High) | 0.01 ppm |
| Response Time (High) | < 35 s |
| Leakage Probe Range | 0–50.00 ppm (up to 100 ppm) |
| Resolution (Leak) | 0.01 ppm |
| Response Time (Leak) | < 10 s |
| Sensor Technology | GSS (Gas Sensitive Semiconductor) with Built-in Compensation Algorithm |
| Operating Environment | –5 to 50 °C, 5–95% RH (non-condensing) |
| Sampling Method | Active pump-assisted aspiration |
| Optional Multi-gas Modules | VOC, CO, NH₃ |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RH800 |
| Pricing | Upon Request |
| Detector | GM Tube |
| Energy Response | ±30% (50 keV–1.3 MeV) |
| Dose Equivalent Rate Range | 0.01 µSv/h–1.00 mSv/h |
| Cumulative Dose Equivalent Range | 0.01 µSv–99.99 mSv |
| Measurement Time | 5 s |
| Relative Error | ±20% (¹³⁷Cs) |
| Alarm Threshold | User-Configurable |
| Power Supply | Two AA batteries |
| Current Consumption | <2 mA |
| Operating Temperature | −10 °C to +40 °C |
| Temperature Drift | ±10% |
| Humidity Drift | ±15% at 95% RH (+40 °C) |
| Dimensions | 118 × 65 × 25 mm |
| Weight | <100 g |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COM3400W |
| Pricing | Available Upon Request |
| Brand | PKSAIR |
|---|---|
| Origin | Japan |
| Model | COM-3700 |
| Measurement Principle | Gerdien Capacitor Method |
| Ion Polarity | Simultaneous Positive & Negative Ion Detection |
| Mobility Range | 0.00269 – 5.38 cm²/V·s (equivalent to ~2000 cm²/V·s in standard mobility scale) |
| Measurement Modes | Auto (dual-polarity) and Manual (single-polarity) |
| Concentration Range | R1: 0–8,000 ions/cm³ |
| R2 | 0–50,000 ions/cm³ |
| R3 | 0–500,000 ions/cm³ |
| R4 | 0–5,000,000 ions/cm³ |
| Display | 16-character × 2-line STN LCD with backlight and ON/OFF control |
| Data Logging | Internal memory for time-stamped measurements |
| Interface | RS-232C output for PC connectivity |
| Compliance | Designed for field-deployable environmental ion monitoring per JIS B 7951 and ISO 16000-22 (indoor air quality — measurement of airborne ions) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AIC2MJ |
| Price Range | USD 700 – 1,400 |
| Airflow Rate | 200 cm³/s |
| Measurable Ion Polarity | Positive and Negative |
| Linear Drift Velocity | 40 cm/s |
| Display | Digital LCD |
| Measurement Range | 10 to 2 × 10⁶ ions/cm³ (extended range up to 2 × 10⁷ ions/cm³) |
| Response Time | ~10 s |
| Measurement Modes | Low / Medium / High Concentration |
| Minimum Detectable Concentration | 10 ions/cm³ (100 ions/cm³ in extended low-noise mode) |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity Limit | ≤99 % RH (non-condensing) |
| Power Supply | 9 V alkaline battery |
| Dimensions | 165.1 × 93.98 × 76.2 mm |
| Weight | 420 g |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NRF31 |
| Pricing | Available Upon Request |
| Detection Radiation Types | Gamma (γ) and X-rays, Neutrons |
| Detector Technology | Silicon Semiconductor |
| Dose Equivalent Range | 1 μSv – 9.999 Sv (0.1 mrem – 999.9 rem) |
| Accuracy | ±10% for γ/X-rays (0.1 mSv – 9.999 Sv, ¹³⁷Cs) |
| Energy Range | γ/X-rays: 35 keV – 6 MeV |
| Neutrons | 0.025 eV – 15 MeV |
| Energy Dependence | ±20% (γ/X), ±50% (neutrons) |
| Angular Dependence | ±20% (γ/X), ±30% (neutrons) |
| Battery Life | >1 year (8 h/day usage) or >4 months (continuous operation) |
| Dimensions | 60 W × 78 H × 33 D mm |
| Mass | ~125 g |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic (PRC) |
| Model | FJ-403GI |
| Pricing | Upon Request |
| Measurement Quantity | Personal Dose Equivalent Hp(10) |
| Dose Range | 0.01 µSv – 9999 mSv |
| Dose Rate Range | 0.1 µSv/h – 200 mSv/h |
| Communication Interface | Infrared (IR) Data Transfer |
| Power Supply | Two AA 1.5 V alkaline batteries or one 3.6 V high-energy lithium battery |
| Battery Life | Up to 1000 hours (at background radiation, 1.5 V) |
| Data Storage Capacity | 160 dose history records (time-stamped, auto-logged) |
| Alarm Functions | Configurable dose rate threshold, cumulative dose threshold, and incremental dose audio alert |
| Compliance | Calibrated to ICRP-defined Hp(10) |
Show next