BrandPolytech
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelEVA32
PriceUSD 8,400 (FOB Anhui)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
ModelHPSE-06
Extraction Channels6 parallel
Temperature RangeAmbient to 210 °C (±1 °C control accuracy)
Pressure Range0–20 MPa
Pump Flow Rate0–100 mL/min
Maximum Pump Output Pressure26 MPa
Solvent SelectionQuaternary solvent system with programmable mixing ratios
Extraction Cell Volumes5, 10, 34, 40, 66, 80, 100, 120 mL (customizable)
Cell MaterialElectropolished stainless steel or specialty alloy with PTFE seals
Collection Vial Capacity60–250 mL
Safety SystemsIntegrated pressure regulation, overpressure cutoff, gas–liquid isolation protection
InterfaceBilingual (Chinese/English) graphical LCD with real-time extraction profile visualization, self-diagnostic capability, and automated nitrogen/solvent purge cycles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginUSA
Model4430 PID Photoinonization Detector
Detector TypePhotoionization Detector (PID)
Ionization SourceUV Lamp (10.6 eV standard)
Design FeatureWindow Purge Technology
CompatibilityUniversal GC Mounting Interface
Power SupplyDedicated High-Voltage Module
Application ScopeSelective Detection of Aromatics, Alkenes, and Other VOCs with Ionization Potentials < 10.6 eV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTR12 Plus
Power Consumption100 W
Input Voltage220 V, 50 Hz
Operating Ambient Temperature0–40 °C
Operating Ambient Humidity≤60 % RH
Maximum Sample Capacity72 samples (1 kg per sampling point)
Tray ConfigurationsAdjustable for 1–8 kg total sample load per chamber
Airflow SystemMulti-layer silent axial fans with independent three-tier fan control
Chamber DesignPerforated wall architecture for enhanced natural convection
MobilityIntegrated swivel casters
ComplianceHJ/T 166–2004 Technical Specification for Soil Environmental Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelNG-70D
Air Inlet Requirement0.85 MPa clean compressed air
Compressor Power Supply380 V, 3.7 kW
Dehumidifier Power Supply220 V, 2 A
Output GasDry nitrogen (O₂ < 5 ppm, H₂O < −40 °C dew point)
Annual Maintenance~30 min filter module replacement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginAnhui, China
Manufacturer TypeOEM Manufacturer
ModelAutomated SPE 606S
PricingUpon Request
Sample Volume Range0.1 mL to unlimited (with particulate tolerance)
Channels6 independent parallel channels
Cartridge Compatibility1 mL, 3 mL, 6 mL, 12 mL SPE cartridges
Disk/Cartridge ConfigurationsCartridge–cartridge, disk–disk, cartridge–disk serial setups
Solvent ChannelsUp to 9 reagents
Elution Solvent DeliveryPrecision syringe pumps
Sample Loading PumpsPeristaltic metering pumps (6-channel simultaneous loading)
Concentration Mode6-channel independent nitrogen blow-down with liquid-level sensing
Control Interface5-inch 65K-color capacitive touchscreen
Data StorageSD card-based method storage and transfer
Compliance StandardsGB/T 20466–2006, GB/T 5750.8–2006, HJ 478–2009, HJ 648–2013, HJ 753–2015, GB/T 21925–2008, CJ/T 141–2001, CJ/T 146–2001, CJ/T 147–2001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginUSA
Model3700
Instrument TypeLaboratory Benchtop Analyzer
Detection PrincipleAmperometric Detection after Acid Distillation-Free Digestion
Detection Range2 ppb – 10 ppm CN⁻
Detection Limit0.002 ppm (2 ppb)
Sample Throughput1 sample per 2 minutes for Total Cyanide
ComplianceASTM D7282, EPA Method 335.4, ISO 11262, GB/T 5750.5–2023
Reagent Preparation Time<10 minutes
System ArchitectureFully Automated, Closed-Loop Reaction Channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ2 Scientific
OriginUSA
ModelPrepLinc 2 Platform
Flow Rate0.01–10.00 mL/min
Maximum Pressure2500 PSI
Flow Stability±0.5%
Autosampler Volume Range100 µL – 1000 mL
Autosampler Capacity36 positions
Integrated ModulesGPC Purification, SPE Extraction, AccuVap® Quantitative Evaporation
UV Detection OptionsFixed- or Variable-Wavelength Detector
Solvent Exchange CapabilityYes
Column CompatibilityGlass GPC columns (700 × 25 mm), High-Efficiency GPC columns (300 × 20 mm), SPE cartridges (1–15 mL)
Software ControlUnified platform with audit trail, method storage, and sequence scheduling
Compliance SupportASTM D7067, ISO 17025 workflows, FDA 21 CFR Part 11–ready data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginUSA
Model5390 PID-XSD Tandem Detector
Detector TypePhotoionization Detector (PID) + Halogen-Specific Detector (XSD)
ConfigurationIn-series dual-detector module with single column outlet interface
Regulatory ComplianceDesigned for ASTM D7622, EPA Method 8021B, and USP <621> chromatographic system suitability requirements
Software IntegrationCompatible with standard GC data systems via analog voltage output (0–1 V) and TTL trigger signals
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Instrument TypeGraphite Block Digestion System
Automation LevelFully Automated
Digestion Positions30 × 50 mL + 16 × 100 mL (configurable modular layout)
Max Heating Temperature230 °C
Temperature UniformityHigh spatial uniformity across graphite block
Reagent Channels8 independent peristaltic pump-driven channels
Sample Processing WorkflowAutomated reagent addition, mixing, temperature-programmed digestion, acid evaporation (dry-down), cooling, and final volumetric定容 via ultrasonic sensor-based precision dispensing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
ModelPT60
Heating Block Capacity60 positions
Temperature RangeAmbient to 230 °C (typical for graphite digestion)
Temperature Uniformity±1.5 °C across block
Programmable Ramp/Soak ProfilesYes, multi-step gradient heating and cooling
Control InterfaceIndependent touchscreen controller with offline operation capability
Corrosion ProtectionPTFE-coated front panel + multi-layer PTFE impregnation on graphite surface
ComplianceDesigned for use in accordance with GB, HJ, SN/T, and ISO 11047:2021 (Determination of metals in environmental and food samples by atomic spectrometry after acid digestion)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelPPM48
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
Model1260 Infinity II HT GPC
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelGPC 220
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInFoMass
OriginBeijing, China
ModelL10
Cooling OptionsLiquid Nitrogen (−189 °C) or Electronic (−90 °C)
Modulation RangeC₄–C₄₅ (LN₂ mode)
Column ConfigurationDual-column serial coupling via cryogenic loop modulator
Modulation CycleProgrammable
Cold Jet FlowPrecisely controllable
Software CompatibilityMDCTM (GC Image LCC)
Structural DesignFixed-angle column routing bracket eliminating manual alignment calibration
Moving PartsNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
ModelRT 220
Heating SurfaceSolid Aluminum Alloy Plate with PTFE Coating
Max Operating Temperature220 °C
Temperature Control Accuracy±1 °C
Heating Rate≤15 °C/min (typical, ambient to 200 °C)
Power Supply220 V AC, 50 Hz
Dimensions (W×D×H)280 × 280 × 120 mm
Weight4.2 kg
ComplianceCE-marked, RoHS-compliant, designed per IEC 61010-1 for laboratory use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
ModelVPS-12/20/32/48
Sample Capacity12/20/32/48 positions
Heating MethodWater-bath (uniform temperature control)
Vacuum Concentration ModeNegative-pressure evaporation with condensate trap and end-point detection
Sample Volume Range≥65 mL (with optional low-volume kit)
Evaporation Endpoint ProtectionAutomatic pressure modulation at ~1 mL residual volume
AgitationAdjustable orbital vortex shaking
Control Interface7-inch HD touchscreen, Chinese-language UI
Method StorageUp to 100 pre-programmed protocols
Cooling RequirementCompatible with standard laboratory recirculating chillers
Vacuum SourceExternal vacuum pump compatible
Concentration LidHeated lid to prevent condensate reflux and cross-contamination
Sealing DesignQuick-release individual well seals
ComplianceDesigned for GLP-compliant sample preparation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginUSA
Model1080
Oxidation MethodHigh-Temperature Catalytic Combustion (680–950 °C)
DetectorSolid-State Non-Dispersive Infrared (SSNDIR)
Detection RangeTC: 50 ppb–2000 ppm
PrecisionRSD < 3%
Sample Injection Volume50 µL–2 mL (adjustable in 10 µL increments)
ComplianceASTM D7573, USP <643>, EPA Methods 415.3 & 9060A, ISO 8245
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginUSA
Model1030W
Detection PrincipleHigh-Temperature Catalytic Oxidation (680 °C) + Solid-State Nondispersive Infrared (SSNDIR) Detection
Measurement Range2 ppb to 30,000 ppm C
Sample TypesLiquid aqueous matrices including suspended solids
Oxidation MethodDual-channel wet chemical oxidation (optional)
Regulatory ComplianceFDA 21 CFR Part 11, GLP/GMP-ready audit trail
InterfaceIntegrated Windows CE OS with touchscreen GUI
ConnectivityEthernet-enabled for LAN integration
AutomationOptional 88-position rotary autosampler with magnetic stirring or >96-position XYZ autosampler with priority/random sampling
Optional FeaturesElectronic Pressure Control (EPC), Electronic Flow Control (EFC), NPOC/TC/TIC/TOC quantification modes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginUSA
Model5360XSD Halogen-Specific Detector
Detector TypeHalogen-selective, GC-compatible
InstallationStandard GC detector port (universal mounting interface)
Configuration OptionsStandalone or in-series with OI 4430 PID
Detection RangeSub-picogram to microgram levels of halogenated compounds
Regulatory ComplianceDesigned to support EPA Method 8021B, ASTM D7412, and ISO 10302 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelPPM32
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ2 Scientific
OriginUSA
ModelPrepLinc2
Flow Rate0.01–10.00 mL/min
Maximum Pressure2500 psi
Flow Stability±0.5% RSD
Autosampler Volume Range100 µL–1000 mL
Autosampler Capacity36 positions
Pump TypeIntegrated Dual-Plunger HPLC Pump
UV DetectionBuilt-in 254/280 nm Dual-Wavelength Detector
System ArchitectureFully Integrated GPC Purification + Online Solvent Evaporation Platform
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOEX
OriginUSA
ModelGC×GC×HiResTOFMS
ConfigurationAgilent 8890 GC Platform + QTOF HiRes TOFMS Detector
Modulator TypeDual-Stage Thermal Modulator (ZX-1 or ZX-2)
SoftwareGC Image™ v2.9+ with HRMS Extension
ComplianceFully compatible with ASTM D7504, ASTM D7901, ISO 17993, and USP <1225> for method validation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolytech
OriginAnhui, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelPL2
Flow Rate0.01–10.00 mL/min
Maximum Pressure2500 psi
Flow Stability±0.5% RSD
Auto-sampler Volume Range100 µL – 10 mL
Auto-sampler Capacity36 positions
Pump Precision≤0.01% RSD (accuracy ≤0.1%)
Injection Reproducibility≤1% RSD
Column ProtectionIntegrated bypass valve with automatic standby-mode hydration control
DetectionBuilt-in UV detector
System ArchitectureIntegrated piston pump, UV detector, autosampler, and column protection module