| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | THA100NO |
| Instrument Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Online Fixed-Mount Analyzer |
| Response Time (T90) | ≤25 s |
| Repeatability | ±1% FS |
| Measurement Range (NO) | 0–500 mg/m³ or 0–50% vol |
| Operating Temperature | 5–45 °C |
| Zero/Full-Scale Stability | ±2% FS / 7 days |
| Linearity Error | ±2% FS |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Pressure Compensation | Yes |
| Output | 4–20 mA analog, 8 isolated relay outputs |
| Display | Color LCD with capacitive touch interface |
| Multi-Gas Capability | Up to 3 components (e.g., NO + optional O₂ + one additional IR-active gas) |
| Optical Core | MEMS-based pulsed infrared source, dual-channel pyroelectric detector |
| Environmental Compliance | Designed for continuous operation in industrial CEMS and laboratory-grade monitoring environments |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic Industrial Oxygen Analyzer |
| Model | EZGAS7000-O |
| Measuring Principle | Paramagnetic Pressure Detection |
| Typical Ranges | 0–5%, 0–10%, 0–21%, 0–100%, 90–100% O₂ (v/v) |
| Linearity Error | ±2% FS |
| Stability | ±2% FS over 7 days |
| Repeatability | ≤1% FS |
| Response Time (T₉₀) | ≤35 s |
| Operating Temperature | 5–45 °C |
| Sample Flow Rate | 0.5 L/min |
| Reference Gas Flow | ~10 mL/min |
| Power Supply | 220 V AC, 50 Hz |
| Analog Output | 4–20 mA (isolated) |
| Digital Interface | RS485 (Modbus RTU protocol) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | THA100R |
| Measurement Principle | Thermal Conductivity Detection |
| Measuring Range | H₂ 0–100% vol |
| Standard H₂ Ranges | 0–1%, 0–10%, 35–75%, 40–80%, 75–100%, 98–100% |
| Operating Ambient Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Linearity Deviation | ±2% FS |
| Response Time (T₉₀) | ≤30 s |
| Output | Isolated 4–20 mA current loop |
| Digital Outputs | 8 relay (switching) outputs |
| Display | Color LCD with touch interface |
| Enclosure | 483 mm (19″) rack-mount chassis |
| Certification | Non-explosion-proof (not for hazardous areas) |
| Pressure Compensation | Built-in atmospheric pressure compensation |
| Temperature Control | Precision thermostatic regulation of sensor block |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TH-analyzer Co., Ltd. |
| Model | EZGAS2000H2 |
| Measuring Range (H₂) | 0–10%, 0–50%, 0–100% |
| Linearity Error | ±2% FS |
| Stability | ±2% FS / 7 days |
| Repeatability | ≤1% FS |
| Response Time (T90) | ≤30 s |
| Operating Ambient Temperature | 5–45 °C |
| Sample Gas Pressure | ≤20 kPa |
| Sample Flow Rate | 0.2–1.0 L/min |
| Power Supply | 12–24 VDC |
| Output Signal | 4–20 mA (isolated) |
| Communication Interface | RS485 (Modbus RTU protocol) |
| Dimensions | 50 × 74 × 75 mm (W × H × D) |
| Enclosure Rating | IP65 (module housing) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Online Gas Analyzer |
| Model | THA100 |
| Detection Principle | NDIR (Non-Dispersive Infrared) |
| Measured Gas | NH₃ |
| Range | 0–300 ppm and 0–100% vol |
| Operating Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Linearity Error | ±2% FS |
| Response Time (T90) | ≤25 s |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Output | 4–20 mA analog, 8 relay outputs |
| Display | Color LCD with touch interface |
| Optional Configuration | Dual-gas IR + O₂ sensor (electrochemical or zirconia) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | THA100-NH3 |
| Instrument Type | Online Gas Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gas | NH₃ (Ammonia) |
| Range | 0–300 ppm and 0–100% vol (dual-range configuration) |
| Operating Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ≤1% FS |
| Linearity Error | ±2% FS |
| Response Time (T90) | ≤25 s |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Output | 4–20 mA analog current loop |
| Digital I/O | 8 isolated relay outputs |
| Display | Color LCD with capacitive touch interface |
| Optional O₂ Channel | Yes (electrochemical or paramagnetic sensor integration) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TH-analyzer |
| Model | THA-IEX-1 |
| Linearity Error | ±2% FS |
| Repeatability | 1% |
| Response Time (T90) | ≤25 s |
| Explosion Protection Rating | Ex d IIC T6 Gb |
| Operating Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Ambient Temperature Effect | ±2% FS (5–45 °C) |
| Measurement Principle | NDIR (Non-Dispersive Infrared) Absorption |
| Detectable Gases | CO, CO₂, CH₄, SO₂, NO, NO₂, N₂O, SF₆, NH₃, O₂ (optional) |