BrandTH-analyzer
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelTHA100NO
Instrument PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypeOnline Fixed-Mount Analyzer
Response Time (T90)≤25 s
Repeatability±1% FS
Measurement Range (NO)0–500 mg/m³ or 0–50% vol
Operating Temperature5–45 °C
Zero/Full-Scale Stability±2% FS / 7 days
Linearity Error±2% FS
Temperature Drift±2% FS (5–45 °C)
Interference Error±2% FS
Pressure CompensationYes
Output4–20 mA analog, 8 isolated relay outputs
DisplayColor LCD with capacitive touch interface
Multi-Gas CapabilityUp to 3 components (e.g., NO + optional O₂ + one additional IR-active gas)
Optical CoreMEMS-based pulsed infrared source, dual-channel pyroelectric detector
Environmental ComplianceDesigned for continuous operation in industrial CEMS and laboratory-grade monitoring environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTH-analyzer
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product TypeDomestic Industrial Oxygen Analyzer
ModelEZGAS7000-O
Measuring PrincipleParamagnetic Pressure Detection
Typical Ranges0–5%, 0–10%, 0–21%, 0–100%, 90–100% O₂ (v/v)
Linearity Error±2% FS
Stability±2% FS over 7 days
Repeatability≤1% FS
Response Time (T₉₀)≤35 s
Operating Temperature5–45 °C
Sample Flow Rate0.5 L/min
Reference Gas Flow~10 mL/min
Power Supply220 V AC, 50 Hz
Analog Output4–20 mA (isolated)
Digital InterfaceRS485 (Modbus RTU protocol)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTH-analyzer
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Region of ManufactureDomestic (China)
ModelTHA100R
Measurement PrincipleThermal Conductivity Detection
Measuring RangeH₂ 0–100% vol
Standard H₂ Ranges0–1%, 0–10%, 35–75%, 40–80%, 75–100%, 98–100%
Operating Ambient Temperature5–45 °C
Stability±2% FS / 7 days
Repeatability±1% FS
Linearity Deviation±2% FS
Response Time (T₉₀)≤30 s
OutputIsolated 4–20 mA current loop
Digital Outputs8 relay (switching) outputs
DisplayColor LCD with touch interface
Enclosure483 mm (19″) rack-mount chassis
CertificationNon-explosion-proof (not for hazardous areas)
Pressure CompensationBuilt-in atmospheric pressure compensation
Temperature ControlPrecision thermostatic regulation of sensor block
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTH-analyzer
OriginBeijing, China
ManufacturerTH-analyzer Co., Ltd.
ModelEZGAS2000H2
Measuring Range (H₂)0–10%, 0–50%, 0–100%
Linearity Error±2% FS
Stability±2% FS / 7 days
Repeatability≤1% FS
Response Time (T90)≤30 s
Operating Ambient Temperature5–45 °C
Sample Gas Pressure≤20 kPa
Sample Flow Rate0.2–1.0 L/min
Power Supply12–24 VDC
Output Signal4–20 mA (isolated)
Communication InterfaceRS485 (Modbus RTU protocol)
Dimensions50 × 74 × 75 mm (W × H × D)
Enclosure RatingIP65 (module housing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTH-analyzer
OriginBeijing, China
Manufacturer TypeManufacturer
Product TypeOnline Gas Analyzer
ModelTHA100
Detection PrincipleNDIR (Non-Dispersive Infrared)
Measured GasNH₃
Range0–300 ppm and 0–100% vol
Operating Temperature5–45 °C
Stability±2% FS / 7 days
Repeatability±1% FS
Linearity Error±2% FS
Response Time (T90)≤25 s
Temperature Drift±2% FS (5–45 °C)
Interference Error±2% FS
Output4–20 mA analog, 8 relay outputs
DisplayColor LCD with touch interface
Optional ConfigurationDual-gas IR + O₂ sensor (electrochemical or zirconia)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTH-analyzer
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelTHA100-NH3
Instrument TypeOnline Gas Analyzer
Measurement PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Target GasNH₃ (Ammonia)
Range0–300 ppm and 0–100% vol (dual-range configuration)
Operating Temperature5–45 °C
Stability±2% FS / 7 days
Repeatability≤1% FS
Linearity Error±2% FS
Response Time (T90)≤25 s
Temperature Drift±2% FS (5–45 °C)
Interference Error±2% FS
Output4–20 mA analog current loop
Digital I/O8 isolated relay outputs
DisplayColor LCD with capacitive touch interface
Optional O₂ ChannelYes (electrochemical or paramagnetic sensor integration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTH-analyzer
OriginBeijing, China
ManufacturerTH-analyzer
ModelTHA-IEX-1
Linearity Error±2% FS
Repeatability1%
Response Time (T90)≤25 s
Explosion Protection RatingEx d IIC T6 Gb
Operating Temperature5–45 °C
Stability±2% FS / 7 days
Ambient Temperature Effect±2% FS (5–45 °C)
Measurement PrincipleNDIR (Non-Dispersive Infrared) Absorption
Detectable GasesCO, CO₂, CH₄, SO₂, NO, NO₂, N₂O, SF₆, NH₃, O₂ (optional)