Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelROXY
PricingAvailable Upon Request
PotentiostatROXY Potentiostats DCC
AutosamplerAS 110 (Cool, Micro, 10-Position Vial)
LC PumpLC 110
Reactor CellIntegrated with Multi-Electrode Detection (MD) and Gas Collection (GC) Electrodes
OrganizerOR 110
SoftwareClarity Chromatography Data System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAntec
OriginNetherlands
ModelDECADE II SDC
Detector TypeElectrochemical Detector (ECD)
Operating ModesDC Amperometry with Advanced Digital Filtering (ADF)
Filter Frequency Range0.5–0.001 Hz (decade steps: 1, 2, 5)
Potential Range±2.00 V
Faraday Column Oven DimensionsHeight 37 cm
Temperature RangeAmbient +7 °C to 45 °C
Temperature Stability±0.1 °C
Flow Cell TypesCentral-jet wall-type electrode (compatible with standard & capillary HPLC columns) and conventional thin-layer electrode
Electrode ConfigurabilityInterchangeable working and reference electrodes (e.g., glassy carbon, gold, platinum, Ag/AgCl)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAntec
OriginNetherlands
ModelROXY™ EC
ApplicationOnline Electrochemical Cell for LC-MS Coupling
CompatibilityUniversal MS Interface (Agilent, Thermo Fisher, Waters, SCIEX, Shimadzu)
ConfigurationFlow-through electrochemical flow cell with integrated electrode cartridge and MS-compatible solvent handling
Regulatory ContextDesigned for GLP-compliant metabolic stability screening and oxidative stress simulation studies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAntec
OriginNetherlands
ModelALEXYS
Instrument TypeConventional High-Performance Liquid Chromatograph with Electrochemical Detection
Flow Rate Range0.001–10 mL/min
Maximum Pressure70 MPa
Autosampler Capacity192 positions
Injection Volume Range1–20 µL
Column Oven Temperature RangeAmbient +7 °C to 60 °C
Detector Output Range−2500 mV to +2500 mV
Data Acquisition Frequency1–100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAntec
OriginNetherlands
ModelDECADE II
Detector TypeElectrochemical Detector (ECD)
Operating ModesDC, Pulse, and Scan
Digital Filter Range0.5–0.001 Hz (1–2–5 decade steps)
Potential Range±2.00 V
Faraday Column Oven DimensionsH 37 cm
Temperature RangeAmbient +7 °C to 45 °C
Temp. Stability±0.1 °C
Flow Cell TypesCentral Jet Wall-Flow Cell & Conventional Thin-Layer Cell
Electrode ConfigurationsSCC, DCC, TCC, QCC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAntec
OriginNetherlands
ModelDECADE Elite
Detector TypeElectrochemical Detector (ECD)
Compatible SystemsHPLC, UHPLC, EC-MS Coupling
Operating ModesDC, Pulsed, Scanning
Signal ProcessingAdvanced Digital Filter (ADF)
Flow Cell Volume Range0–300 nL (continuously adjustable)
Cell DesignCentral Jet-Wall Electrode Configuration
Temperature ControlIntegrated Faraday-Shielded Thermostatic Chamber
ComplianceDesigned for GLP/GMP environments