- All
- Favorite
- Popular
- Most rated
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | EM RES102 |
| Maximum Sample Size | Ø 25 mm × 12 mm |
| Tilting Angle Range | –90° to +90° (dependent on sample holder) |
| Ion Beam Energy | 0.8 keV to 10 keV (adjustable in 0.1 keV increments) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 X |
| Excitation Source | Tunable White Light Laser (WLL), Pulsed |
| Detection | Spectral Detection with Adjustable Bandpass, Up to 8 Simultaneous Excitation Lines |
| Fluorescence Lifetime Imaging (FLIM) Capability | Yes |
| Scan Mode | Galvo + Resonant Scanner |
| Zoom Optics | Continuous Spectral Zoom (λ-Zoom) |
| Microscope Frame | Inverted or Upright Configurable Platform |
| Vibration Isolation | Compatible with Active Damping Optical Tables |
| Software | LAS X Professional Suite with Spectral Unmixing, FLIM Analysis, and GLP-Compliant Audit Trail Modules |
| Compliance | Designed for ISO 13485-aligned workflows |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | CV 5030 |
| Throughput | 400 slides/hour |
| Slide Compatibility | Standard microscope slides and variable coverslip sizes |
| Mounting Media Support | Xylene-based and xylene-free media |
| Operation Modes | Wet-mount and dry-mount |
| Integrated Fume Extraction | Activated carbon filtration system |
| System Integration | Compatible with Leica ST5010/ST5020 stainers |
| Compliance | Designed for GLP/GMP-aligned pathology laboratories |
| Footprint | Open-architecture design for flexible lab integration |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | CM1520 |
| Maximum Sample Size | 55 mm × 55 mm or 50 mm × 80 mm |
| Section Thickness Range | 2 µm to 60 µm |
| Sectioning Increment | 25 µm + 3 µm step adjustment |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | SpectraMax 190 |
| Detection Method | Absorbance (UV-Vis) |
| Automation Level | Fully Automated |
| Wavelength Range | 190–850 nm (1 nm step) |
| Minimum Bandwidth | 2 nm |
| Absorbance Range | 0–4.0 OD |
| Pathlength Correction | Patented PathCheck™ sensor (temperature-independent, converts to 1-cm equivalent) |
| Detection Channels | 8-sample + 1-reference photodiode array |
| Temperature Control | Ambient +4°C to 45°C (±0.5°C accuracy) |
| Orbital Shaking | Linear or orbital, programmable speed/amplitude |
| Microvolume Capability | SpectraDrop™ module (2 µL/sample, 64 wells/scan, dsDNA sensitivity: 2 ng/µL) |
| Software | SoftMax Pro® 7 (GLP-compliant, 21 CFR Part 11 ready, audit trail, 19 curve-fit models, custom equation editor) |