- All
- Favorite
- Popular
- Most rated
| Brand | ABTEC |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A5 |
| Pricing | Available Upon Request |
| THD+N (Typical) | –108 dB |
| Max Input Voltage (Balanced) | 300 Vrms |
| Analog Output Amplitude | 21 Vrms |
| Supported Bluetooth Codecs | SBC, aptX, aptX-LL, aptX-HD, AAC, LHDC (HWA) |
| Digital Interface Options | SPDIF, TOSLINK, AES/EBU, I²S, HDMI, BT, PDM (optional), DSI-O (optional, higher sample rate support) |
| Software API Support | VB.NET, C#.NET, LabVIEW |
| Measurement Capabilities | Level/Gain/Phase, Channel Balance, Frequency Response, THD+N, IMD, SNR, Noise, Crosstalk, Interchannel Phase, DC Level, Frequency Measurement, CMRR, Oscilloscope & Spectrum Monitoring, Stepped Level/Frequency Sweep, DC Level Sweep, Q-Peak Noise |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | Diffuse Illumination / 0° Viewing (with Specular Component Included) |
| Light Source | Pulsed Xenon Lamp |
| Repeatability | ΔE*ab ≤ 0.07 (SD, 30 measurements on white calibration tile at 10-sec intervals after white calibration) |
| Measurement Aperture | CR-400: Φ8 mm / Φ11 mm |
| CR-410 | Φ50 mm / Φ53 mm |
| Inter-instrument Agreement | ΔE*ab ≤ 0.6 (CR-400), ≤ 0.8 (CR-410) against BCRA Series II 12-color tile set |
| Observer | CIE 1931 2° Standard Observer |
| Illuminants | C, D65 (and others per color space) |
| Color Spaces | CIE XYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, Munsell (C-illuminant only), CMC (l:c), CIE 1994, CIE 2000, Lab99, LCh99, CIE WI-Tw (D65 only), WI ASTM E313 (C only), YI ASTM D1925 & E313 (C only), User-defined metrics (up to 6) |
| Display | Backlit dot-matrix LCD (multilingual: English, German, French, Italian, Spanish, Japanese) |
| Memory | 1000 measurements (probe + processor combined), 100 standard colors |
| Interface | RS-232C, USB 2.0 (via CR-A105 adapter) |
| Power | 4× Ni-MH batteries or dedicated AC adapter |
| Operating Temp. | 0–40°C, RH ≤85% (non-condensing) |
| Dimensions (W×H×L) | CR-400: 105×218×63 mm |
| CR-410 | 105×245×63 mm |
| Weight | CR-400: ~540 g |
| CR-410 | ~560 g (incl. batteries, excl. cable) |
| Brand | Specim (Finland) |
|---|---|
| Origin | Finland |
| Model | AFX10 / AFX17 |
| Spectral Range | AFX10 — 400–1000 nm (Vis-NIR), AFX17 — 900–1700 nm (NIR) |
| Spatial Resolution | Up to 1280 pixels across track |
| Frame Rate | Up to 300 fps (configurable) |
| Integration | GNSS/IMU-aided georeferencing |
| Platform Compatibility | UAVs (multirotor, fixed-wing), light aircraft |
| Onboard Processing | Embedded real-time data acquisition & preprocessing unit |
| Data Output Format | ENVI-compatible raw and radiometrically calibrated cubes (.bil/.hdr) |
| Weight | < 2.5 kg (full integrated system) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CA-2500 |
| Minimum Measurable Luminance | 0.05 cd/m² |
| Luminance Range | 0.05–5,000,000 cd/m² (with lens-dependent dynamic range extension) |
| Sensor Type | XYZ-filtered CCD with CIE 1931 spectral responsivity match |
| Lens Options | Standard, Wide-angle, Telephoto (with macro coupling ring) |
| Synchronization Frequency Range | 4–2,000 Hz |
| Factory Calibration | Per-lens, per-focus-position optical calibration |
| Included Software | CA-S25w (with autofocus assistance, auto-alignment guidance, and automatic ROI detection) |
| SDK Included | Yes, for custom application integration |
| Compliance | Designed for ISO/CIE-compliant photometric and colorimetric evaluation in R&D and production QA environments |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CA-410 |
| Probe Options | CA-VP427A / CA-VP410A (down to 0.0003 cd/m²) |
| CIE Compliance | CIE 1931 2° Standard Observer, optional CIE 170-2:2015 2° Standard Observer (CA-P427C / CA-P410C probes) |
| Interface | USB (virtual COM port, driver-free), RS-232C |
| Auto-Zero Calibration | Yes |
| Synchronization | External sync input (1.8 V TTL-compatible, from March 2021 production onward) |
| Software Support | CA-SDK2 (backward-compatible with CA-210/CA-310 systems) |
| Brand | Anton Paar |
|---|---|
| Origin | Japan (manufactured in Austria) |
| Model | DMA 5001 |
| Instrument Type | Laboratory Benchtop Densitometer |
| Sample Type | Solid & Liquid Compatible |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Density Range | 0 to 3 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Accuracy (Density) | ±0.000005 g/cm³ |
| Repeatability (Density) | ±0.000001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | 10.1″ TFT WXGA Touchscreen (1280 × 800 px) |
| Data Storage | >10,000 measurements with embedded camera images |
| Measurement Time | ≤40 s per sample |
| Operating System | Real-time embedded OS (8× faster than previous generation) |
| CPU | Dual-core processor (2× speed increase) |
| Compliant | FDA 21 CFR Part 11, GLP/GMP audit trail, ISO/IEC 17025 traceability support |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | ZTS-DPU |
| Accuracy | ±0.2% F.S. ±1 digit |
| Sampling Rate | Up to 2000 Hz |
| Display | 4-digit OLED (color, high-brightness) |
| Operating Temperature | 0–40 °C |
| Humidity Range | 20–80% RH |
| Overload Protection | 200% F.S. (audible/visual alarm at >110% F.S.) |
| Battery Life | 8 h (2 h recharge) |
| Output Interfaces | USB, RS-232C, Mitutoyo-compatible digital output, 2 VDC analog output, comparator outputs (3-step: –NG/OK/+NG), auxiliary I/O for displacement sensing |
| Data Storage | Internal 1000-point memory + optional USB flash drive (up to 100 data points/sec) |
| Units | N, kgf, lbf (auto-scaled per range) |
| Weight (indicator only) | ~490 g |
| Compliance | CE-marked |
| Brand | Specim (Finland) |
|---|---|
| Origin | Finland |
| Model | Specim IQ |
| Form Factor | Handheld |
| Spectral Range | 400–1000 nm |
| Spatial Resolution | 512 × 512 pixels |
| Field of View (TFOV) | 31° × 31° |
| Interface | USB 3.0, Wi-Fi |
| Onboard Processing | Integrated ARM-based computing platform |
| Storage | Removable microSD card (UHS-I compatible) |
| Battery | Rechargeable Li-ion (up to 90 min continuous operation) |
| Environmental Rating | IP54 (dust- and splash-resistant) |
| Compliance | CE, FCC, RoHS |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | 45°c:0° (45° circumferential illumination / 0° vertical viewing) |
| Spectral Range | 360–740 nm |
| Wavelength Interval | 10 nm (FWHM ≈ 10 nm) |
| Measurement Areas | MAV Ø8.0 mm / SAV Ø3.0 mm |
| Gloss Measurement | 60°, 0–200 GU |
| Repeatability | ΔE*ab ≤ 0.04 (std dev, white tile, n=30) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.15 (BCRA Series II, 12 tiles) |
| Display | 2.7″ TFT color LCD |
| Battery Life | ~3,000 measurements (standalone, 10 s interval) |
| Compliance | CIE No.15, ISO 7724-1, ISO 2813, ASTM E179, ASTM D523, JIS Z 8722, JIS Z 8741 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | ProMetric I/Y Series |
| Sensor Resolution Options | 2 MP (I2/Y2), 8 MP (I8), 16 MP (I16/Y16), 29 MP (I29/Y29) |
| Sensor Type | Scientific-grade CCD, 12-bit, interline transfer |
| Cooling | Thermoelectric (TE) stabilization |
| Dynamic Range | High-dynamic-range (HDR) multi-exposure mode |
| Optical Interface | Interchangeable C-mount lenses with variable focal length and f-number |
| Spectral Matching | CIE 1931 photopic luminosity function (V(λ)) and CIE 1931/1964 color matching functions |
| Filter System | Precision CIE-matched color filters + calibrated neutral density (ND) filters |
| Software | ProMetric Control & Analysis Suite (v5.x), TrueTest™, TrueMura™, PM-KB Keyboard Analysis Module |
| Compliance | Designed for ISO/CIE-compliant photometric and colorimetric measurements |
| Connectivity | Gigabit Ethernet, USB 3.0 |
| Brand | Chroma |
|---|---|
| Origin | Taiwan |
| Model | CS-150 / CS-160 |
| Luminance Range | 0.0001–999,900 cd/m² (CS-150), 0.0001–9,999,000 cd/m² (CS-160) |
| V(λ) Photopic Luminous Efficiency Match | Improved vs. CS-100A |
| Measurement Method | Non-contact, Single-point Spectral Radiance Integration |
| Optical System | SLR-type with Eyepiece Viewfinder and External LCD Display |
| Minimum Measurable Spot Diameter | 0.4 mm (with optional macro lens, CS-160 only) |
| Power Supply | Rechargeable Battery |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | GT-200 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Specialized (e.g., Acid Number Determination in Gasoline) |
| Display | 5.7-inch Color LCD |
| Connectivity | USB, RS-232 (COM), GLP-compliant Data Logging |
| Software | Titration Viewer TV-200 |
| Automation Capacity | Up to 12 burettes + 24-position autosampler |
| Endpoint Detection | Smart End Point Detection (S.E.D.) Algorithm |
| Compliance | GLP Support (Calibration Traceability, User Access Levels, Audit Trail) |
| Brand | Radiant Vision Systems |
|---|---|
| Origin | USA |
| Model | SIG-400 |
| Application | Near-field radiometric and photometric characterization of small light sources |
| Compatible Detector | ProMetric® imaging colorimeters and photometers |
| Output Format | Radiant Source Model™ (RSM), IES, EULUMDAT, ASAP, LightTools, TracePro, Zemax-compatible ray sets |
| Software Platform | ProSource® v5.0+ |
| Brand | Tektronix |
|---|---|
| Origin | USA |
| Model | MSO54 / MSO56 / MSO58 |
| Analog Bandwidth | 350 MHz – 2 GHz |
| Sample Rate | 6.25 GS/s (per channel) |
| Record Length | 62.5 M – 125 M points |
| FlexChannel Inputs | 4 / 6 / 8 analog channels (each convertible to 8 digital channels) |
| Max Digital Channels | 32 / 48 / 64 (with TLP058 logic probes) |
| Vertical Resolution | Up to 16 bits (via 12-bit ADC + DSP enhancement) |
| Display | 15.6-inch Full HD capacitive touchscreen |
| Optional Integrated AWG | 1-channel arbitrary/function generator |
| OS Option | Windows 10 IoT Enterprise (optional) |
| Serial Protocol Analysis | I²C, SPI, USB 2.0, Ethernet (10/100BASE-T), CAN, LIN, RS-232/422/485 |
| Jitter Analysis | Advanced real-time jitter decomposition and visualization |
Show next