Biological Liquid Nitrogen Tanks
Filter
Showing 1–30 of 38 results
| Brand | Abeyance |
|---|---|
| Origin | USA |
| Model | A1000 |
| Capacity | Up to 1,000 L (liquid nitrogen hold time ≥ 120 days) |
| Operating Temperature Range | −190 °C to −150 °C (vapor-phase zone) |
| Construction | Dual-walled stainless steel with high-vacuum insulation |
| Control System | Microprocessor-based touchscreen interface with Wi-Fi/Ethernet connectivity |
| Compliance | Designed per ISO 13485 principles for medical device storage environments |
| Alarm Options | SMS, email, and cloud-based notifications via secure TLS-encrypted API |
| Brand | Abeyance |
|---|---|
| Origin | USA |
| Model | A220 |
| Capacity | Up to 220 × 2 mL vials (standard configuration) |
| Cooling Mode | Vapor-phase cryogenic storage (−150 °C to −190 °C operating range) |
| Interface | 7-inch capacitive touchscreen with Wi-Fi & Ethernet connectivity |
| Alarm System | SMS/email alerts, cloud-based monitoring, audit-trail logging |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| compatible with ISO 20387 | 2018 biobank accreditation requirements |
| Power | 100–240 V AC, 50/60 Hz, <15 W standby consumption |
| Dimensions (W×D×H) | 650 × 650 × 1,120 mm |
| Net Weight | 82 kg |
| Brand | Abeyance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | A440 |
| Price Range | USD 35,000 – 42,000 |
| Brand | Abeyance |
|---|---|
| Origin | USA |
| Model | A700 |
| Capacity | ≥700 L (vapor-phase storage volume) |
| Static Evaporation Rate | ≤0.8 L/day (typical, at 25°C ambient) |
| Temperature Uniformity | ±5°C across storage chamber (–196°C to –150°C operational range) |
| Max. Sample Capacity | Up to 40,000 cryovials (2 mL) with standard 10×10 racks |
| Vacuum Integrity | <1×10⁻⁴ Pa after initial pump-down, maintained for ≥15 years per ISO 23756:2021 qualification |
| Compliance | Meets ASTM F2697-22 (Standard Specification for Vapor Phase Liquid Nitrogen Freezers), FDA 21 CFR Part 11–ready software architecture |
| Brand | Air Liquide |
|---|---|
| Origin | France |
| Model | GT14/6 |
| Capacity | 14 L |
| Empty Weight | ~12.5 kg (typical for GT14/6) |
| Static Hold Time | ≥21 days (at 20°C ambient) |
| Neck Diameter | 50 mm |
| Inner Vessel Material | Stainless Steel 304 |
| Outer Shell Material | Anodized Aluminum Alloy |
| Insulation | Multi-layer reflective foil + vacuum gap |
| Compliance | ISO 9001:2000 certified |
| Transport Certified | ADR/RID/IATA compliant |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A220 |
| Pricing | Upon Request |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Model | YDS-10-80 |
| Capacity | 10 L |
| Neck Diameter | 80 mm |
| Total Height | 550 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 7.8 kg |
| Full Weight | 15.9 kg |
| Canister Quantity | 6 |
| Canister Diameter | 63 mm |
| Canister Height | 120 mm |
| Cryovial Slots per Rack | 198 (11 racks × 18 vials) |
| Static Evaporation Rate | 0.18 L/day |
| Hold Time in Static Mode | 56 days |
| Vacuum Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YDS-15 |
| Capacity | 15 L |
| Canister Quantity | 6 |
| Canister Diameter | 38 mm |
| Canister Height | 120 mm |
| Straws per Canister | 3 |
| Cryovials per Straw (6 vials/straw) | 54 |
| Static Evaporation Rate | 0.11 L/day |
| Static Hold Time | 134 days |
| Neck Opening Diameter | 50 mm |
| Total Height | 591 mm |
| Outer Diameter | 394 mm |
| Empty Weight | 8.5 kg |
| Full Weight | 20.7 kg |
| Vacuum Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YDS-3 |
| Capacity | 3.15 L |
| Canister Quantity | 6 |
| Canister Diameter | 38 mm |
| Canister Height | 120 mm |
| Cryovial Strips per Canister | 3 |
| Cryovials per Strip (6/vial strip) | 54 |
| Static Evaporation Rate | 0.12 L/day |
| Static Hold Time | 26 days |
| Neck Opening Diameter | 50 mm |
| Total Height | 435 mm |
| Outer Diameter | 224 mm |
| Empty Weight | 3.1 kg |
| Full Weight | 5.7 kg |
| Vacuum Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Brand | Banagee |
|---|---|
| Origin | Beijing, China |
| Model | YDS-6-80 |
| Capacity | 6 L |
| Neck Diameter | 80 mm |
| Total Height | 480 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 5 kg |
| Full Weight | 9.9 kg |
| Bucket Quantity | 6 |
| Bucket Diameter | 63 mm |
| Bucket Height | 120 mm |
| Cryovials per Rack | 198 (6 per strip × 11 strips per bucket) |
| Static Evaporation Rate | 0.18 L/day |
| Hold Time | 33 days |
| Vacuum Warranty | 5 years |
| Structural Material | High-strength aluminum alloy |
| Surface Finish | Electrostatic powder coating |
| Compliance | GB/T 5458–2012 |
| Brand | BENDER |
|---|---|
| Origin | Sichuan, China |
| Model | YDH-25-216F |
| Capacity | 25 L |
| Liquid Nitrogen Adsorption Capacity | 10 L |
| Static Evaporation Rate | 0.89 L/day |
| Holding Time | 11 days |
| Cryovial Capacity | 500 × 25-well boxes or 550 × 100-well boxes |
| Blood Bag Capacity | 250 × 250 mL or 125 × 500 mL |
| Neck Diameter | 216 mm |
| Total Height | 741 mm |
| Outer Diameter | 396 mm |
| Empty Weight | 12.5 kg |
| Full Weight | 31.8 kg |
| Material | High-Strength Anodized Aluminum Alloy |
| Compliance | GB/T 5458–2012 |
| Warranty | 1-year comprehensive, 5-year vacuum integrity |
| Brand | BENDER |
|---|---|
| Origin | Sichuan, China |
| Model | YDH-4-125 |
| Capacity | 4 L |
| Neck Diameter | 125 mm |
| Total Height | 521 mm |
| Outer Diameter | 300 mm |
| Empty Weight | 7 kg |
| Full Weight | 9.6 kg |
| Static Evaporation Rate | 0.45 L/day |
| Holding Time | 4 days |
| Vacuum Insulation Layer Warranty | 5 years |
| Standard Compliance | GB/T 5458–2012 |
| Sample Compatibility | Cryovials, 25- and 100-compartment cryoboxes, 50 mL blood bags (up to 6 units), standard blood bag racks |
| Standard Accessories | 1 x inner canister (lift bucket), 1 x neck plug, 1 x locking lid |
| Optional Accessories | Temperature alarm module, certified IATA-compliant aviation transport case |
| Brand | AZENTA (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Biocision Cryopod™ |
| Price Range | USD $2,500 – $6,200 |
| Brand | Chart MVE |
|---|---|
| Origin | USA |
| Model | 616 |
| Capacity | Up to 39,000 × 1.2/2.0 mL cryovials |
| Operating Mode | Liquid-phase storage (optional vapor-phase conversion with accessory kit) |
| Neck Opening Diameter | Wide-neck design (≥125 mm typical for 616 class) |
| Static Hold Time | ≥180 days (typical, dependent on ambient conditions and fill level) |
| Dimensions (H × D) | Approx. 1,420 × 760 mm |
| Net Weight | ~180 kg (empty) |
| Optional | Backup battery for temperature monitoring system |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CG-1 |
| Capacity | 46 L (below rotary rack) / 407 L (total) |
| Evaporation Rate | 8 L/day |
| Hold Time | 33 days |
| External Dimensions | 864 mm (Ø) × 1524 mm (H) |
| Net Weight | 295 kg |
| Operating Temperature | ≤ −135 °C (vapor phase) |
| Control System | Auto Protector Plus with 7-level capacitive liquid level sensors, dual temperature monitoring (sample & vapor), RS232 data logging, 3–5 day battery backup |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CryoMizer |
| Capacity Options | CM-1 / CM-2 / CM-3 / CM-4 |
| Operating Modes | Vapor-phase (−135 °C) and Liquid-phase (−196 °C) Storage |
| Standard Configuration | Cryogenic Rack System, Castor-Mounted Base, LN₂ Level Gauge |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Darwin |
| Construction | Aerospace-grade Aluminum Alloy |
| Storage Mode | Vapor-phase or Liquid-phase |
| Capacity Options (2 mL Cryovials) | 750, 2000, 3600, 4800, 6000, 3618, 4824 |
| Neck Diameter | Optimized for Rapid Sample Access |
| Static LN₂ Evaporation Rate | <0.8 L/day (typ. for 3600-capacity unit) |
| Vacuum Insulation | Multi-layer reflective foil + high-vacuum interspace (<1×10⁻³ Pa) |
| Optional Accessories | CryoMemo™ Real-time Monitoring System, Active De-gassing Unit |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | GT |
| Pricing | Upon Request |
| LN₂ Capacity | 2–40 L |
| Sample Storage Capacity | 150–7,300 × 0.5 mL Straws |
| Static Hold Time | 25–350 days |
| Brand | Froilabo |
|---|---|
| Model | Origin |
| Construction | Stainless Steel |
| Origin | France |
| Capacity Range | 500–1636 L |
| Sample Storage Capacity | 27,300–90,400 × 1.2/2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Evaporation Rate | Low (Optimized Vacuum Insulation) |
| Optional Accessories | Aluminum Rotating Rack, CryoMemo Monitoring System |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Intended Use | Long-term cryopreservation of biological specimens |
| Brand | Froilabo |
|---|---|
| Origin | United Kingdom |
| Model | Polaris |
| Capacity Range | 5,200–94,500 × 2 mL Cryovials |
| Construction | Medical-Grade Stainless Steel |
| Cooling Mode | Vapor-Phase Storage |
| LN₂ Evaporation Rate | Optimized Low-Loss Design |
| Control Interface | CryoLog Color Touchscreen Display |
| Security | Three-Tier User Authentication & Audit Trail Logging |
| Compliance | Designed for GLP/GMP-aligned biobanking environments |
| Certification | CE-marked per EU Medical Device Regulation (MDR) Annex I essential requirements |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | TR Series |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Vessel Type | Static, Non-Pressurized Liquid Nitrogen Dewar |
| Intended Use | Long-Term Biological Sample Storage at –196 °C |
| Regulatory Context | Designed for GLP/GMP-Compliant Environments |
| Compliance | Meets ISO 23775-1:2022 (Cryogenic Vessels — Part 1: Design and Construction) |
| Safety Certification | CE Marked per PED 2014/68/EU (Pressure Equipment Directive) for auxiliary pressure systems (e.g., optional LN₂ transfer pumps) |
| Capacity Range | 10 L to 100 L (nominal static hold time: 12–120 days depending on model and ambient conditions) |
| Evaporation Rate | 0.12–0.85 L/day (model-dependent, measured at 20 °C ambient, 50% fill level) |
| External Dimensions | Ø220–Ø520 mm × H500–H1200 mm |
| Net Weight | 8.5–42 kg (empty, aluminum-only configuration) |
| Neck Tube Diameter | 50–125 mm |
| Accessories Supported | Programmable LN₂ Level Sensors, Auto-Fill Systems, RFID Sample Rack Integration Kits, Temperature Monitoring Probes (–200 °C to +85 °C), Locking Lid Assemblies |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Voyager |
| Capacity Range | 200–786 L |
| Sample Capacity | 10,400–38,400 × 2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Neck Opening | Wide-mouth |
| Evaporation Rate | Optimized Low-loss Design |
| Monitoring System | CryoMemo Integrated Temperature & Level Monitoring |
| Construction | Medical-grade 304/316 Stainless Steel |
| Compliance | Designed to meet ISO 13485 principles for medical device storage environments |
| Intended Use | Long-term cryopreservation of biological specimens in GxP-regulated settings |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | VSHIPPER |
| Construction | Aerospace-grade aluminum alloy |
| Intended Use | Short-to-medium duration biological sample transport (including air freight) |
| Static Hold Time | Up to 10 days (typical, dependent on ambient conditions and fill level) |
| Capacity | 10–30 L liquid nitrogen (model-dependent) |
| Sample Access | Top-loading with porous cryo-absorbent liner for controlled LN₂ release and reduced boil-off during access |
| Compliance | IATA PI 650 compliant for air transport of biological substances |
| Certification | CE-marked per EU Pressure Equipment Directive (PED 2014/68/EU) for non-pressurized cryogenic vessels |
| Brand | Froilabo |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | XT Series |
| Price Range | USD 6,800 – 13,500 |
| Brand | Jinfeng |
|---|---|
| Origin | Sichuan, China |
| Model | YDS-30-125 |
| Geometric Volume | 31.5 L |
| Empty Weight | 14.2 kg |
| Neck Opening Diameter | 125 mm |
| Outer Diameter | 446 mm |
| Total Height | 685 mm |
| Static Evaporation Rate | 0.35 L/day |
| Static Holding Time | 90 days |
| Number of Square Lift Canisters | 6 |
| Canister Dimensions | 82 × 84 mm |
| Box Dimensions | 76 × 76 mm |
| 2 mL Cryovial Capacity | 600 |
| Optional Lockable Lid | Yes |
| Standard Accessories | 1 Plug Cap + 1 Protective Sleeve |
| Brand | Millet |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | MLT-YDYTT |
| Price Range | USD 7,000 – 14,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSystem 750 / 2000 / 4000 / 6000 |
| Price Range | USD $2,500 – $6,200 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | SC3/3, SC8/5, SC11/17, SC16/11, SC Millennium 20, SC20/20, SC33/26, SC36/32 |
| Price Range | USD $1,400 – $2,800 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVE XC |
| Price Range | USD $1,300 – $2,600 |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 455 |
| Price | €50,000 |
| Static Evaporation Rate | <0.5 L/day |
| Dispensing Flow Rate | Droplet-to-2 L/min (Fixed, Non-adjustable) |
| Operating Pressure | <200 mBar |
| Hose Pre-cooling Time | 10–40 s (Dependent on LN₂ Level) |
| Power Supply | 115 V / 230 V AC or 12 V AC/DC |
| Average Power Consumption | 10 W (Peak: 50 W) |
| Dewar Capacity | 35 L / 50 L |
| Dewar Diameter | 480 mm / 500 mm |
| Dewar Height | 643 mm / 727 mm |
| Empty/Full Weight | 13 / 41.5 kg (35 L) or 17 / 57.5 kg (50 L) |
| Standard Equipment | Controller, Power Unit, Interconnecting Cables |
| Optional Accessories | 5-Wheel Mobile Base (10 cm height), LN₂ Pump Mounting Bracket |