Biomass Spectrometer
Filter
Showing all 19 results
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF 6600 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Resolution | 30,000 (FWHM at m/z 1,000) |
| Sensitivity | 10.1 fmol (substance P, S/N ≥ 10) |
| Mass Accuracy | < 100 ppm (internal calibration), < 5 ppm (external calibration with lock mass) |
| Stability | ≤ 10 ppm RMS over 24 h |
| Acquisition Rate | 50 Hz (MS/MS spectra per second) |
| SWATH™ Acquisition | Up to 200 variable isolation windows per cycle |
| Brand | Agena Bioscience |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MassARRAY Nucleic Acid Mass Spectrometer |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Scope | General-Purpose Biomolecular Analysis |
| Resolution | >750 across full detection range |
| Sensitivity | ≥5% for routine somatic mutation detection |
| Stability | Measurement deviation ≤ ±5% |
| Throughput | ≤15 minutes for 96 samples |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Autof ms1600 |
| Price Range | USD 420,000 – 560,000 |
| Instrument Type | MALDI-TOF Mass Spectrometer |
| Application Scope | Universal |
| Resolution | ≥3600 (Linear Mode) |
| Sensitivity | 50 fmol/µL (Insulin, S/N ≥ 60) |
| Mass Accuracy | <60 ppm (Internal Calibration) |
| Data Acquisition Rate | 0.5 GBit/sec |
| Stability | High Long-Term Operational Stability |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | autoflex maX |
| Instrument Type | TOF-TOF |
| Application Scope | Universal |
| Laser Repetition Rate | up to 2 kHz |
| Mass Resolution | up to 26,000 (m/z 1,000–5,000) |
| Mass Accuracy | sub-ppm (calibrated) |
| Detection Sensitivity | low amol (for peptides) |
| Ion Source | Perpetual™ laser-cleanable MALDI source |
| Detector | FlashDetector™ with 10-bit digitizer |
| Software Suite | Compass (flexControl, flexAnalysis, BioTools, GlycoWorkbench, Polymerix) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Time-of-Flight (TOF) |
| Configuration | Benchtop MALDI-TOF |
| Operating Modes | Linear & Reflectron |
| Resolution | Up to 15,000 (m/z 1,000–2,000, reflectron mode) |
| Laser | Nitrogen laser, 337 nm, adjustable repetition rate up to 60 Hz |
| Ion Source | microScout™ pulsed ion extraction source |
| Detector | Microchannel plate (MCP) |
| Vacuum System | Oil-free, maintenance-free turbomolecular pump with WhisperMode™ acoustic dampening |
| Sample Target | AnchorChip™ patterned stainless steel target |
| Software Platform | Compass Suite (including ProteinScape™, BioTools™, Polymerix™) |
| Regulatory Compliance Option | Compass Security Pack (21 CFR Part 11 compliant audit trail, electronic signatures, user access control) |
| Sample Throughput | High-speed automated acquisition enabled by precise AnchorChip™ spot positioning and integrated autoPSD (automated post-source decay) capability |
| Ionization Mode | Positive/Negative selectable |
| Mass Range | Broad dynamic range suitable for small molecules (e.g., lipids, additives), peptides, oligonucleotides, and synthetic polymers |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | TOF-TOF |
| Application Domain | Universal |
| Model | neofleX™ |
| Category | Biomass Spectrometer |
| Import Status | Imported |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ultrafleXtreme |
| Instrument Type | TOF-TOF |
| Application Domain | Universal |
| Category | Biomass Spectrometer |
| Distribution Status | Authorized Distributor (Imported) |
| Brand | Digena |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TOF Mass Spectrometer |
| Model | DP-TOF 96A |
| Resolution | Mass resolution >700 (FWHM at m/z 500) |
| Sensitivity | ≤0.012 µmol (for oligonucleotide standards) |
| Mass Accuracy | ≤5×10⁻⁴ relative error (m/z) |
| Mass Stability | Relative m/z drift ≤±3×10⁻⁴ over 8 h |
| Sampling Rate | 1 GHz digitizer |
| Regulatory Status | Registered with Zhejiang Medical Device Administration (Registration No.: Zhejiang MD Registration No. 20232221555) |
| Intended Use | In vitro diagnostic (IVD) applications in clinical molecular laboratories, supporting nucleic acid-based assays including SNP genotyping, methylation analysis, and pathogen identification |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometer |
| Model | Ebio Reader 3700 Plus |
| Regulatory Status | Class II Medical Device (Registration No.: Tianjin NMPA Approval No. 20222220402) |
| Intended Use | Clinical Microbiology Identification, Biomarker Profiling, SNP Genotyping, Viral Peptide Detection, Foodborne Pathogen Screening |
| Compliance | Meets GB/T 19001–2016 (ISO 9001:2015), YY/T 0287–2017 (ISO 13485:2016), and relevant Chinese NMPA medical device technical requirements |
| Brand | Dongxi Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Classification | Domestic (PRC) |
| Model | Ebio Reader™ 3700M |
| Instrument Type | Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometer |
| Resolution | ≥2500 (FWHM) |
| Sensitivity | ≥250 amol/μL Febrinopeptide Human B (S/N ≥50:1) |
| Mass Stability | ≤300 ppm relative mass drift over 8 h |
| Sampling Rate | 2 GS/s |
| Mass Accuracy | ≤200 ppm (internal calibration) |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | East & West Analytical Instruments Co., Ltd. |
| Instrument Type | TOF Mass Spectrometer |
| Resolution | ≥2500 (FWHM) |
| Sensitivity | 250 amol/μL Febrinopeptide Human B (S/N ≥50:1) |
| Mass Stability | ≤300 ppm relative deviation in m/z over 8 h |
| Sampling Rate | 2 GS/s |
| Mass Accuracy | ≤200 ppm (internal calibration), ≤300 ppm (external calibration) |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TOF Mass Spectrometer |
| Model | Ebio Reader 3700 |
| Resolution | ≥2500 (FWHM) |
| Sensitivity | 250 amol/μL for Human Fibrinopeptide B |
| Mass Stability | ≤300 ppm relative mass drift over 8 hours |
| Sampling Rate | 2 GS/s |
| Mass Accuracy | ≤200 ppm (internal calibration), ≤300 ppm (external calibration) |
| Laser | N₂ laser, 337 nm, 1–60 Hz repetition rate, lifetime ≥9×10⁷ shots |
| Flight Tube Material | Low-thermal-expansion alloy |
| Vacuum System | Oil-free diaphragm pump |
| Data Acquisition | FPGA-accelerated digitizer with on-board spectral preprocessing |
| Ion Mode | Positive-mode standard |
| Brand | Genewish |
|---|---|
| Origin | Zhejiang, China |
| Model | Gene TOF 3100 |
| Mass Analyzer Type | Time-of-Flight (TOF) |
| Application Domain | In Vitro Diagnostic (IVD) Devices & Clinical Molecular Testing |
| Regulatory Classification | Domestic IVD Instrument (China NMPA-compliant design basis) |
| Configuration | Integrated PCR-MS workflow platform with automated sample purification and matrix-assisted laser desorption/ionization (MALDI) source |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Time-of-Flight (TOF) Hybrid Quadrupole-TOF Mass Spectrometer |
| Model | TripleTOF 6600 |
| Resolution | 10,000 (FWHM at m/z 956) |
| Sensitivity | ≤10 amol β-galactosidase tryptic peptide (S/N ≥10) |
| Mass Accuracy | ≤10 ppm RMS (calibrated) |
| Mass Stability | ≤10 ppm over 24 h |
| Acquisition Rate | Up to 100 Hz MS/MS spectra |
| Linear Dynamic Range | 5 orders of magnitude |
| Q1 m/z Range | Up to 2250 Th |
| SWATH Window Flexibility | 2–25 Da variable width, up to 200 windows per cycle |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iMScope QT |
| Instrument Type | MALDI-Q-TOF Hybrid Imaging System |
| Spatial Resolution | ≤5 µm |
| Sensitivity | Equivalent to LCMS-9030 |
| Mass Accuracy | <1 ppm over 24 h at ambient temperature |
| Acquisition Speed | ≥50 pixels/sec |
| Mass Precision | <1 ppm |
| Detection Platform | Integrated Optical Microscope–MALDI Source–Q-TOF Mass Spectrometer |
| Brand | Shimadzu |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | MALDI EasyCare |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Resolution | >5000 FWHM in Linear Mode |
| Application Scope | General-Purpose Biomolecular and Small-Molecule Analysis |
| Form Factor | Benchtop |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MALDImini-1 |
| Instrument Type | Ion Trap–Time-of-Flight (IT-TOF) Hybrid |
| Resolution | >4000 (FWHM at m/z 500) |
| Sensitivity | Low-femtomole (fmol) level for peptides and small molecules |
| Stability | High long-term signal stability under continuous operation |
| Acquisition Rate | 0.6 spectra/s |
| Mass Accuracy | ±200 ppm (external calibration, typical for MALDI-MS in linear mode) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MCE-202 MultiNA |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Instrument Type | Orbitrap Tribrid |
| Model | Fusion Lumos |
| Resolution | 30,000 (at m/z 200, MS1) |
| Mass Accuracy | ≤10 ppm (internal calibration) |
| Sensitivity | 10.1 (fmol-level S/N for standard peptides) |
| Stability | ≤10 ppm RMS mass drift over 24 h |
| Acquisition Rate | 50 Hz (MS/MS in parallel mode) |
| Mass Range | m/z 50–6,000 |