A.KRÜSS / A.KRÜSS Optronic
Filter
Showing all 5 results
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | AR4 |
| Product Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Measurement Range | 1.3000 – 1.7000 nD |
| Accuracy | ±0.0002 nD |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR301-95 |
| Sample Measurement Range | 1.3330–1.5318 nD |
| Measurement Accuracy | ±0.00015 nD |
| Temperature Range | 5–40 °C |
| Temperature Accuracy | ±0.5 °C |
| Resolution | 0.0001 nD |
| Display | Digital LCD |
| Power Supply | 9 V battery (detachable AC adapter optional) |
| Prism Material | Optical glass |
| Housing Material | Stainless steel sample stage + polymer body |
| Dimensions | 180 × 100 × 60 mm |
| Weight | 500 g |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR6000 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 10–80 °C (±0.1 °C) |
| Digital Display | Yes |
| Refractive Index Range | nD 1.3200–1.5800 (standard), up to 1.7000 with extended Brix mode |
| Accuracy | ±0.0001 nD |
| Resolution | 0.0001 nD |
| Brix Range | 0–95 % |
| Brix Accuracy | ±0.1 % |
| Brix Resolution | 0.1 % |
| Prism Material | Sapphire |
| Light Source | 590 nm LED (>100,000 h lifetime) |
| Measurement Time | ~4 s |
| Interface | RS-232, USB, Ethernet |
| Data Storage | Integrated SQL database (99 methods, 999 results) |
| Compliance | GLP, FDA 21 CFR Part 11 ready, ICUMSA-compliant temperature compensation |
| IP Rating | IP65 (measurement cell) |
| Power Supply | 90–260 V AC, 50/60 Hz, 60 W |
| Operating Ambient | 15–35 °C |
| Sample Temp Range | 10–80 °C |
| Temperature Sensor | PT100 |
| Display | 5.7″ LCD (320 × 240 px), touchscreen |
| Brand | A.Krüss / A.Krüss Optronic |
|---|---|
| Origin | Germany |
| Model | DS7800 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0.0000–1.9999 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052-18, ASTM D5002, ISO 12185:1996, ISO 2811-3:2011, SH/T 0604-2000, GB/T 21862.3-2008 |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Heating Rate | 1 °C/min |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Diameter | 1.4 mm |
| Sample Capacity | 1 capillary per measurement |
| Temperature Resolution | 0.1 °C |
| Cooling | Integrated fan-assisted cooling |
| Safety Rating | IP20 |
| Dimensions (L×W×H) | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Interface | RS-232 |