| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | API 5000™ |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose |
| Mass Range | 10–1200 m/z |
| Sensitivity | <100.1 fg on-column for selected analytes (e.g., reserpine, caffeine) |
| Resolution | Unit resolution (0.5–0.7 Da full width at half maximum) |
| Mass Accuracy | ≤0.1 Da (calibrated) |
| Operating Pressure Range | Up to 1200 psi (LC system compatible) |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Configuration | API4000 System (incl. ESI & APCI Ion Sources, Turbo V™ Source, Analyst® Software v1.6.2 or later) |
| Condition | Factory-Refurbished, Fully Qualified, IQ/OQ Performed |
| Compliance | Meets ASTM D7592, USP <1225>, ISO/IEC 17025:2017 requirements for method validation support |
| Warranty | 12-month comprehensive hardware & software support |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | API5000 |
| Configuration | LC-20AD HPLC + Nitrogen Generator |
| Condition | Refurbished & Functionally Verified |
| Brand | AB SCIEX |
|---|---|
| Origin | Netherlands |
| Model | EKSPERT CHIPLC nanoLC 425 |
| Type | Nano-flow Liquid Chromatography System |
| Configuration | Used (Refurbished & Verified) |
| Intended Use | Analytical-scale and nano-scale LC separation for proteomics, metabolomics, and biomarker discovery |
| Brand | AB SCIEX |
|---|---|
| Origin | Singapore |
| Model | ekspert nanoLC 400 |
| Instrument Type | Nano-flow Liquid Chromatography System |
| Configuration | Pre-owned (Refurbished & Functionally Verified) |
| Flow Rate Range | 50 nL/min – 20 µL/min |
| Column Compatibility | 50–150 µm ID capillary columns |
| Detection Interface | ESI-compatible, designed for coupling with mass spectrometers (e.g., AB SCIEX TripleTOF®, QTRAP® systems) |
| Operating Software | ekspert microLC / nanoLC Control v3.x or later |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software options |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | M3 MicroLC |
| Configuration | Refurbished Unit |
| Category | Microflow Liquid Chromatography System |
| Intended Use | Coupled with Mass Spectrometry (MS) for High-Sensitivity Bioanalysis |
| Brand | AB SCIEX |
|---|---|
| Model | QTRAP 5500 |
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC-manufactured system assembly and integration) |
| Price | USD 210,000 (FOB Shanghai, ex-works, subject to configuration verification) |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 4500 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Application Scope | General-Purpose LC-MS/MS |
| Mass Range | 1000 Da |
| Sensitivity (MRM) | 100:1 (S/N) |
| Resolution | 0.5 Da (FWHM) |
| Mass Accuracy | 0.1 Da |
| Operating Pressure Range | 600 Torr (vacuum system) |
| Scan Speed | 12,000 Da/sec |
| Mass Stability | <0.1 Da/24 h |
| Dynamic Linear Range | 5 orders of magnitude |
| MRM Dwell Time | 1 ms |
| Ion Source | Turbo V™ with ESI and APCI capability |
| Brand | AB SCIEX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB SCIEX Triple Quad 6500+ + Shimadzu Nexera LC-40BX3 |
| Quotation | Upon Request |
| Brand | AB SCIEX |
|---|---|
| Model | TripleTOF 5600+ |
| Configuration | LC-MS/MS System with TOF-MS and MS/MSALL Acquisition |
| Mass Analyzer Type | Orthogonal Acceleration Time-of-Flight (oa-TOF) with Quadrupole Front-End |
| Resolution (FWHM) | ≥35,000 at m/z 1,000 |
| Mass Accuracy | < 2 ppm (internal calibration), < 5 ppm (external calibration) |
| Scan Speed | Up to 50 Hz for MS and MS/MS in high-resolution mode |
| Dynamic Range | >4 orders of magnitude |
| Ion Source Options | Turbo V™ or DuoSpray™ Ionization |
| LC Compatibility | Fully Compatible with Shimadzu, Waters, Thermo, and Agilent UHPLC Systems |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows via Analyst TF Software |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF 6600 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Resolution | 30,000 (FWHM at m/z 1,000) |
| Sensitivity | 10.1 fmol (substance P, S/N ≥ 10) |
| Mass Accuracy | < 100 ppm (internal calibration), < 5 ppm (external calibration with lock mass) |
| Stability | ≤ 10 ppm RMS over 24 h |
| Acquisition Rate | 50 Hz (MS/MS spectra per second) |
| SWATH™ Acquisition | Up to 200 variable isolation windows per cycle |