A&D
Filter
Showing 1–30 of 96 results
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Instrument |
| Model | AD-3253 / AD-3253B |
| Thickness Range | 0.8–100 mm (AD-3253: 2–200 mm) |
| Accuracy | ±0.1 mm |
| Weight | 180 g |
| Power | Single AA alkaline battery |
| Battery Life | >30 h continuous operation (at 25°C, 5 mm steel sample) |
| Auto Power-Off | After 5 min idle |
| Display | Backlit LCD |
| Units | mm / inch selectable |
| Sound Velocity Input | Adjustable via keypad, stored non-volatile memory |
| Calibration | Single-point material calibration for velocity determination |
| Standard Accessories | Protective leather case, 5 mm calibration block, instruction manual, probe holder (AD-3252 only), dual probe (optional) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-3253 / AD-3253B |
| Measurement Principle | Ultrasonic Pulse-Echo |
| Thickness Range (AD-3253) | 2.0–200.0 mm |
| Thickness Range (AD-3253B) | 0.8–100.0 mm |
| Accuracy | ±0.1 mm ±1.0% (AD-3253, 2–100 mm) / ±0.1 mm ±0.5% (AD-3253B, 0.8–40 mm) |
| Resolution | 0.1 mm |
| Display | LCD |
| Units | mm / inch |
| Sound Velocity Adjustment | Yes |
| Sampling Rate | 4 Hz |
| Operating Temperature | 0°C to 50°C |
| Power | 2 × AA alkaline batteries |
| Battery Life | ~30 hours |
| Weight | 180 g |
| Dimensions | 68 × 120 × 27 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AD-4212C-300 |
| Instrument Type | Analytical Balance Module |
| Capacity Range | 200–500 g |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ≤0.001 g |
| Stabilization Time | 0.5 s |
| Data Output Rate | 50 Hz |
| Protection Rating | IP65 |
| Housing Material | Stainless Steel |
| Pan Dimensions | 50 mm × 50 mm |
| Interface Options | Analog Output / Comparator Output / BCD Output |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AD-4212C-301 |
| Instrument Type | Analytical Balance Module |
| Capacity | 51 g / 320 g |
| Readability | 0.0001 g / 0.001 g |
| Repeatability | ≤ 0.0002 g / ≤ 0.001 g |
| Pan Size | 50 mm × 50 mm |
| Stabilization Time | 0.5 s |
| Data Output Rate | 50 Hz |
| Protection Rating | IP65 |
| Housing Material | Stainless Steel |
| Interface Options | Analog Output / Comparator Output / BCD Output |
| Mounting Width | 59 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4401 |
| Display Resolution | 1/16,000 |
| Internal A/D Resolution | 1/1,000,000 |
| Sampling Rate | 100 Hz |
| Input Sensitivity | 0.3 µV/d |
| IP Rating | IP65 (Front Panel) |
| Communication Interfaces | RS-232 (Current Loop & Optional TTL), RS-422/485 (Optional), BCD (Optional), 4–20 mA Analog Output (Optional) |
| Max Device Count on RS-422/485 Network | 10 units |
| Operating Modes | 8 Predefined Weighing & Control Modes |
| Built-in Diagnostics | I/O, A/D, Peripheral Detection |
| Auto-Compensation | Fuzzy Logic-Based Drop Compensation & Re-Feed Control |
| Data Logging | Batch Weight Summation & Cycle Count Accumulation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4402 |
| Sampling Rate | 100 Hz |
| Internal A/D Resolution | 1:1,000,000 |
| Display Resolution | 1:16,000 |
| Input Sensitivity | 0.3 µV/d |
| IP Rating | IP65 (Front Panel) |
| Programmable Recipes | 100 |
| Stored Materials | 100 |
| I/O Channels | 11 inputs / 11 outputs |
| Configurable Functions | 50 |
| Alarm Outputs | 8 |
| Communication Interfaces | RS-232, RS-422/485, BCD, Parallel I/O, Analog Output, CC-Link, DeviceNet, PROFIBUS |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4404 |
| Sampling Rate | 100 Hz |
| Internal A/D Resolution | 1 part in 1,000,000 |
| Display Resolution | 1/16,000 |
| Input Sensitivity | 0.3 µV/d |
| Zero Tracking | Static & Dynamic with Real-time Compensation |
| Communication Interfaces | Standard RS-485 + Current Loop Output |
| Optional I/O Modules | BCD, Relay, RS-232/422/485, Parallel, Analog Output |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AD-4408A |
| Pricing | Upon Request |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Industrial Weight Indicator |
| Model | AD-4408C |
| Pricing | Upon Request |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4532B |
| Input Impedance Compatibility | <10 kΩ |
| Excitation Voltage Options | 5 V (up to four 350 Ω sensors) or 2.5 V (up to four 120 Ω or eight 350 Ω sensors) |
| Calibration | Digital calibration (sensor sensitivity input) or physical load calibration |
| Zero Adjustment Range | ±50% of full-scale output voltage |
| Span Adjustment Range | ±0.25 mV/V to ±3 mV/V |
| Minimum Input Sensitivity | 0.6 µV/d |
| Minimum Display Resolution | 0.12 µV/d |
| Maximum Display | ±999999 |
| Linearity | 0.02% F.S. (within ±1 digit) |
| A/D Conversion Rate | 2000 samples/sec |
| Zero Temperature Coefficient | ±0.5 µV/°C (typ.) |
| Span Temperature Coefficient | ±30 ppm/°C (typ.) |
| Display | 6-digit, 7-segment LED (14 mm height) |
| Keypad | 6 keys |
| Comparison Output | HI/OK/LO relay contacts (0.1 A, 250 V AC) or MOSFET outputs (0.5 A, 30 V DC) |
| Hold Modes | Sample hold, peak hold, valley hold, bipolar hold |
| Analog Amplified Output | ±10 V (fixed at 3.2 mV/V sensitivity), linearity 0.05% F.S., tempco 100 ppm/°C |
| D/A Output | ±10 V, resolution 1/10000, tempco 100 ppm/°C |
| Communication | Modbus-RTU (RS-485) |
| Power Supply | 85–250 V AC, 50/60 Hz, ~20 W |
| Operating Environment | –5 to +40 °C, ≤85% RH (non-condensing) |
| Dimensions (W×H×D) | 96 × 96 × 155 mm |
| Panel Cutout | 92 × 92 mm |
| Optional Interfaces | BCD (AD-4532B-01), RS-232C (AD-4532B-04), ±10 V / 4–20 mA D/A (AD-4532B-07), Ethernet (AD-4532B-08) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Scale |
| Model | AD-4961 |
| Pricing | Upon Request |
| Capacity | 500 g / 2000 g |
| Resolution | 0.01 g / 0.1 g |
| Accuracy (3σ) | ±0.08 g / ±0.18 g |
| Sorting Speed | 320 pcs/min |
| Conveyor Width | 200 mm |
| Conveyor Length | 350 mm |
| Conveyor Material | Polyurethane |
| Conveyor Speed | 15–20 m/min |
| Detectable Item Dimensions | L 30–300 mm × W ≤200 mm |
| Load Cell Type | Strain-Gauge Based |
| Display | 7-inch Color TFT Touchscreen (WVGA) |
| Memory Capacity | 1000 Recipes (10 Groups × 100 Presets) |
| Communication Interfaces | Modbus TCP, Modbus RTU, RS-232C (for metal detector integration), Ethernet (TCP/IP), USB (for data logging, firmware update, and image import) |
| Digital I/O | 4-channel dry-contact input, 8-channel relay output |
| Ingress Protection | IP65 |
| Operating Environment | −5 to +40 °C, ≤85% RH (non-condensing) |
| Power Supply | Single-phase AC 100–240 V (±10%/−15%), 50/60 Hz, 180 VA |
| External Dimensions (W×D×H) | 700 mm × 600 mm × (700–860) mm |
| Net Weight | Approx. 35 kg |
| Construction Materials | Stainless steel control housing & frame |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4961-6K-3035 |
| Construction | Stainless Steel Frame |
| Drive Mechanism | Direct Gear Motor Transmission |
| Communication Interface | Standard Modbus RTU/TCP |
| Modular Architecture | Feed Conveyor Unit, Weighing Conveyor Unit, Control Unit, Frame Assembly |
| Maintenance Design | Hot-Swappable Functional Modules |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned food/pharma production environments |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4971 |
| Detection Aperture | 350 mm (W) × 80 / 150 / 230 mm (H) |
| Detection Sensitivity | Fe Ø0.3–0.7 mm |
| Conveyor Belt Width | 250 mm |
| Belt Length | 800 mm |
| Belt Speed | 10–60 m/min |
| Display | 7-inch color TFT LCD touchscreen |
| IP Rating | IP65 |
| Communication | Modbus RTU/TCP standard |
| Data Output | Ethernet + USB storage (PDF reports, histograms, X̄-R charts, trend plots) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-8121B |
| Printing Technology | Serial Dot-Matrix |
| Character Format | 5×7 dot matrix (2.5 mm H × 1.8 mm W) |
| Characters per Line | 16 |
| Interface Options | RS-232C or Current Loop (20 mA) |
| Power Supply | AC adapter or 4×AA alkaline batteries |
| Programmable Interval Printing | 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 30 min |
| Statistical Functions | Min, Max, Mean, Standard Deviation, Coefficient of Variation, Range |
| Print Head Lifetime | Approx. 500,000 lines |
| Dimensions (W×D×H) | 180 × 160 × 80.5 mm |
| Weight | ~1.2 kg |
| Brand | A&D |
|---|---|
| Model | AD-8127 |
| Printing Method | Impact Dot-Matrix |
| Character Format | 7×9 dots |
| Character Size | 1.6 mm (W) × 3.2 mm (H) |
| Print Speed | ~1.6 lines/sec |
| Paper Feed Speed | ~4 lines/sec |
| Characters per Line | 24 |
| Operating Temp. | 0–40 °C, 35–85% RH (non-condensing) |
| Storage Temp. | −20–60 °C, 10–90% RH (non-condensing) |
| Interface | RS-232C / Current Loop |
| Power Supply | AC Adapter AX-TB135 or AX-TB285 (Input: AC 100 V ±10% / −15%, 50/60 Hz) |
| Power Consumption | ~36 VA (incl. adapter) |
| Dimensions (W×D×H) | 174 × 141 × 87 mm |
| Weight | ~500 g |
| Standard Accessories | Ribbon cartridge, plain paper roll, AC adapter, identification label, user manual, RS-232C cable (D-Sub9P/D-Sub25P configurable) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BA-6TE |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 6.2 g |
| Readability | 1 µg (0.000001 g) |
| Repeatability | ≤ 0.001 mg |
| Calibration Method | Internal Motorized Auto-Calibration with Built-in Weights |
| Minimum Weight Detection | Auto-Verified per USP <41> |
| Static Elimination | DC Ionizer-Free Electrostatic Neutralization |
| Compliance | GLP/GMP/GCP/ISO Data Output Format |
| Environmental Monitoring | Real-Time Ambient Temperature & Humidity Tracking |
| Connectivity | RS-232, USB, Ethernet, Optional GPIB and PLC I/O |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Semi-Micro Analytical Balance |
| Model | BH225TE |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.015 mg (at 50 g), 0.03 mg (at 200 g) |
| Internal Calibration | Yes |
| Stabilization Time | ~7 s |
| Pan Diameter | Ø90 mm |
| Net Weight | ~8 kg |
| Compliance | GLP/GMP/GCP/ISO-compliant data output, USP <41> and <1251> compliant minimum weight assessment, FDA 21 CFR Part 11 ready (with optional audit trail software) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Ultra-Micro Balance |
| Capacity | 520 g |
| Readability | 1 µg |
| Repeatability | ≤ ±0.001 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Interface | RS-232C and USB (dual simultaneous output) |
| Data Storage | 200 measurement records (100 timestamped), 50 calibration logs |
| Display | High-contrast white-backlit LCD |
| Draft Shield | Conductive-coated mesh-patterned glass with electrostatic neutralization (integrated ionizer) |
| Brand | A&D |
|---|---|
| Origin | Tianjin, China |
| Model | CL102 |
| Max Capacity | 100 g |
| Readability | 0.01 g |
| Repeatability | ±0.01 g |
| Linearity Error | ±0.02 g |
| Stabilization Time | ≤2.5 s |
| Pan Diameter | φ115 mm |
| Dimensions (W×D×H) | 186 × 275 × 87 mm |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 10–70 %RH |
| Warm-up Time | 30–60 min |
| Power Input | 220 V AC / 50 Hz |
| Output | 12 V DC / 1 A |
| RS232 Baud Rates | 300–9600 |
| Accuracy Class | Class II |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EJ-120D |
| Weighing Capacity | 120 g |
| Readability | 0.01 g |
| Density Resolution | 0.01 g/cm³ |
| Repeatability | 0.01 g |
| Pan Size | 110 mm |
| Display | Backlit LCD, 16 mm digit height |
| Interface Options | RS-232 or driver-free USB |
| Power Supply | AC adapter and rechargeable battery dual mode |
| Compliance | GLP/GMP/GCP and ISO-compliant calibration reporting |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Intrinsically Safe Laboratory Balance |
| Model | EK-300EP |
| Max Capacity | 300 g |
| Readability | 0.01 g |
| Repeatability | ≤ ±0.01 g |
| Calibration | External |
| Weighing Units | g, oz, ct, dwt, tl, ozt, lb, GN |
| Display | High-contrast LCD with 16 mm digit height |
| Power | 4 × AA alkaline batteries (up to 250 h continuous operation) |
| Pan Material | Washable stainless steel |
| Auto Power-Off | Yes |
| Certifications | IECEx Ex ia IIB T3 Ga |
| FM/FMc (NEC 505) | AEx / Ex ia IIB T3 |
| FM/FMc (NEC 500) | IS / I / 1 / C,D / T3C |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-120i / EK-200i / EK-300i / EK-410i / EK-610i / EK-600i / EK-1200i / EK-2000i / EK-3000i / EK-4100i / EK-6100i / EK-6000i / EK-12Ki |
| Capacity Range | 120 g – 12,000 g |
| Readability | 0.01 g – 1 g |
| Display | Backlit LCD with 60,000 internal resolution |
| Interface | RS-232C standard |
| Compliance | GLP, GMP, ISO 9001 |
| Power Options | AC adapter or optional rechargeable Li-ion battery |
| Software Compatibility | Win-CT for data logging and instrument control |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / EK-3000iD |
| Instrument Type | Benchtop Solid Density Analyzer |
| Measurement Principle | Archimedean Buoyancy Method (Air Weight / (Air Weight − Immersed Weight) × Reference Liquid Density) |
| Density Range | 0–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ (EK-300iD) / 0.01 g/cm³ (EK-3000iD) |
| Temperature Range | 0–100 °C |
| Minimum Sample Mass | 0.001 g |
| Reference Liquids | Water, Kerosene, or User-Defined Liquids (Density Input Range: 0.000–2.000 g/cm³) |
| Temperature Compensation | Automatic |
| Data Storage | 200 Records |
| Interface | RS-232 |
| Compliance | GLP/GMP/GCP Audit Trail Ready, ISO/IEC 17025 Support Enabled |
| Software | WinCT Data Acquisition Suite (Windows-compatible, Excel export, statistical analysis, graphing) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-iD/GF-D |
| Measurement Principle | Archimedes’ Principle |
| Weighing Range | 300 g to 3100 g (model-dependent) |
| Readability | 0.001 g to 0.1 g |
| Density Resolution | 0.001 g/cm³ |
| Repeatability | ±0.002 g/cm³ |
| Display | High-contrast LCD (EK-iD) / Fluorescent display (GF-D), 16 mm digit height |
| Stabilization Time | 1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Weighing Pan Size | 108 × 80 mm |
| Interface | RS-232 standard port |
| Software | WinCT for Windows (data logging, statistical analysis, Excel export) |
| Compliance | Built-in GLP/GMP/ISO audit trail support |
| Environmental Adaptation | Adjustable response speed (FAST/MID/SLOW) |
| Power Options | AC adapter or rechargeable battery (EK-iD only, up to 10 h operation) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EM-30KAM / EM-60KAM / EM-60KAL / EM-150KAL |
| Capacity | 30 kg / 60 kg / 60 kg / 150 kg |
| Readability | 10 g / 5 g / 2 g |
| Linearity | ±10 g / ±20 g / ±20 g / ±50 g |
| Pan Dimensions (W×D) | 300 × 350 mm / 300 × 350 mm / 400 × 500 mm / 400 × 500 mm |
| Overall Dimensions (W×D×H) | 300 × 560 × 450 mm / 300 × 560 × 450 mm / 400 × 710 × 750 mm / 400 × 710 × 750 mm |
| Approx. Weight | 4 kg / 4 kg / 7 kg / 9.5 kg |
| IP Rating | IP65 |
| Power | Rechargeable battery (200 h typical runtime) or AC adapter |
| Display | 26 mm white-backlit LCD, 360° rotatable indicator head |
| Optional Accessories | RS-232C interface (EM-03), adjustable-angle stand (EM-12), desktop/wall-mount bracket (EM-13) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model Variants | FG-30KAM, FG-60KAM, FG-150KAM, FG-150KAL |
| Capacity | 30 kg / 60 kg / 150 kg |
| Readability | 2 g / 5 g / 10 g (FG-30), 5 g / 10 g / 20 g (FG-60), 10 g / 20 g / 50 g (FG-150) |
| Pan Dimensions | 300 × 380 mm (M-type), 390 × 530 mm (L-type) |
| Stabilization Time | ≤1 s |
| Display | Large LCD with status indicators (Stable/Net/Tare/Zero) |
| Power | AC adapter or 4× C-cell batteries (R14P/LR14) |
| Calibration | External weight-based |
| Compliance | JIS B 7301, OIML R76 (Class III), ISO/IEC 17025 traceable procedures |
| Optional Interfaces | RS-232C (FG-23), RS-232C + Comparator Output (FG-24) |
| Features | Counting mode (sample sizes: 5/10/20/50/100), HI/OK/LO comparator display & output, auto-power-off (~5 min at zero), gravity acceleration correction, digital filtering, adjustable tilt display pole |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Product Type | Imported Precision Balance |
| Model | FX-1200CT |
| Instrument Category | Analytical/Precision Balance |
| Maximum Capacity | 1260 ct / 252 g |
| Readability | 0.001 ct / 0.1 mg |
| Repeatability | ≤ ±0.001 ct / ±0.2 mg |
| Calibration | External |
| Stabilization Time | ≤ 2 s |
| Display | Backlit High-Contrast LCD with Large Digits |
| Interface Options | RS-232C, USB (FXi-02), Ethernet (WINCT-Plus), Optional Rechargeable Battery (FXi-09) |
| Dimensions (W×D) | 198 × 294 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | External Calibration Precision Balance |
| Max Capacity | 3200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Stabilization Time | ~1 s |
| Pan Diameter | Ø150 mm |
| Dimensions (W×D×H) | 193 × 262.5 × 85.5 mm |
| Protection Rating | IP65 |
| Interface | RS-232, USB (driver-free), optional Ethernet |
| Software | WinCT-Plus (standard WinCT included) |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP data traceability support |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | FX-GD |
| Capacity Range | 122 g to 3200 g (model-dependent) |
| Readability | 0.001 g or 0.01 g |
| Repeatability | ±0.001 g or ±0.01 g |
| Linearity | ±0.002 g or ±0.02 g |
| Pan Diameter | 130 mm or 150 mm |
| Dimensions (W×D×H) | 193 × 262.5 × 85.5 mm |
| Weight | ~2.5 kg |
| Interface | USB (driver-free), Ethernet (with WinCT-Plus software), optional built-in rechargeable battery (FXi-09 variant) |
| Display | High-contrast fluorescent LCD |
| Units | g, pcs, %, ct, mom |
| Compliance | GLP, GMP, ISO 9001, ISO/IEC 17025 applicable |
| Stabilization Time | ≤1 s |
| Statistical Functions | Counting, % weighing, piece counting, net/gross/tare |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | FX-120i / FX-1200i |
| Capacity | 122 g / 1220 g |
| Readability | 0.001 g / 0.01 g |
| Stabilization Time | ≤1 s |
| Display | High-contrast fluorescent LCD |
| Interface | RS-232C, USB (driver-free), Ethernet |
| Compliance | GLP, GMP, GCP, ISO 9001 |
| Power | AC adapter + built-in rechargeable battery |
| Features | Auto-calibration, ACAI (Automatic Counting Accuracy Improvement), animal weighing, parts counting, statistical analysis, comparison mode, underhook weighing, data storage |