A&D
Filter
Showing 61–90 of 96 results
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MPA-10 |
| Pipette Type | Single-Channel Electronic Pipette |
| Volume Range | 0.5–10 µL |
| Accuracy (at 1 µL / 10 µL) | ±4% / ±1% |
| Precision (CV at 1 µL / 10 µL) | 2.5% / 0.4% |
| Power Source | Rechargeable Li-ion Battery (USB Charging) |
| Calibration | User-Accessible Gravimetric and Volumetric Adjustment |
| Operating Modes | Standard Pipetting, Multiple Dispensing, Mixing, Reverse Pipetting |
| Tip Ejection | Spring-Loaded, Tool-Free Installation & Sealing |
| Display | Impact-Resistant LCD with Shock-Absorbing Housing |
| Ergonomics | Low-Actuation-Force Touch Buttons, Optimized Weight Distribution for Reduced Repetitive Strain |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MPA-10000 |
| Instrument Type | Single-Channel Electronic Pipette |
| Automation Level | Motorized |
| Channel Count | 1 |
| Volume Range | 0.1–10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.5% (at 0.1 mL), ±1.0% (at 5.0 mL), ±0.5% (at 10.0 mL) |
| Precision (CV) | ≤0.6% (at 0.1 mL), ≤0.15% (at 5.0 mL and 10.0 mL) |
| Power Source | Rechargeable Lithium-ion Battery |
| Charging Interface | USB-C |
| Tip Attachment | Spring-assisted, leak-tight seal without manual compression |
| Calibration | User-accessible gravimetric and volumetric calibration routines |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported |
| Model | MPA-1200 |
| Instrument Category | Single-Channel Pipette |
| Automation Level | Electronic |
| Channels | 1 |
| Volume Range | 100–1200 µL |
| Maximum Capacity | 1200 µL |
| Accuracy | ±0.5% at 1200 µL, ±2.5% at 100 µL |
| Precision (CV) | ±0.15% at 1200 µL, ±0.6% at 100 µL |
| Power Source | Rechargeable Li-ion Battery |
| Charging Interface | USB-C |
| Calibration | User-performed gravimetric and volumetric calibration |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MPA-20 |
| Pipette Type | Electronic Single-Channel |
| Volume Range | 2–20 µL |
| Accuracy (at 2 µL / 20 µL) | ±4% / ±1% |
| Precision (CV, at 2 µL / 20 µL) | 2.5% / 0.4% |
| Power Source | Rechargeable Lithium-ion Battery (USB Charging) |
| Display | Impact-Resistant LCD |
| Tip Attachment | Auto-Seal Snap-fit Mechanism |
| Calibration | User-Accessible Gravimetric and Volumetric Adjustment |
| Compliance | Designed to support ISO 8655-2:2022 and GLP/GMP workflows |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MPA-200 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Motorized |
| Channels | 1 |
| Volume Range | 10–200 µL |
| Maximum Capacity | 200 µL |
| Accuracy | ±2.5% at 10 µL, ±0.6% at 200 µL |
| Precision (CV) | ≤1.0% at 10 µL, ≤0.15% at 200 µL |
| Power Source | Rechargeable Lithium-ion Battery |
| Charging Interface | USB-C |
| Calibration | User-accessible gravimetric and volumetric calibration routines |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MS-70 |
| Heating Method | 400 W Linear Halogen Lamp with SRA (Secondary Radiation Assist) Technology |
| Weighing Range | 71 g |
| Readability | 0.0001 g |
| Moisture Resolution | 0.001 % / 0.01 % / 0.1 % |
| Drying Temperature Range | 30–200 °C |
| Interface | RS-232C |
| Compliance | GLP/GMP/ISO 9001, USP <921>, ASTM E1064, ISO 11857, EN ISO 13726 |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MS-70 |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 71 g |
| Readability | 0.0001 g |
| Moisture Content Resolution | 0.001 % / 0.01 % / 0.1 % |
| Temperature Range | 30–200 °C |
| Sample Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | 6.0 kg |
| Compliance | GLP/GMP/ISO-compliant data logging, RS-232 interface, WinCT-Moisture software support |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Instrument |
| Model | MS-74AT |
| Heating Method | 400 W Linear Halogen Lamp |
| Moisture Resolution | 0.001% |
| Weighing Capacity | 71 g |
| Weighing Accuracy | 0.0001 g |
| Temperature Range | 30–200 °C |
| Measurement Modes | Standard / Timed / Custom |
| Heating Profiles | Standard / Gradual / Step / Rapid |
| Sample Pan Diameter | Ø90 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Instrument |
| Model | MS74A |
| Heating Method | 400 W Linear Halogen Lamp |
| Moisture Resolution | 0.001% |
| Weighing Capacity | 71 g |
| Weighing Accuracy | 0.0001 g |
| Moisture Measurement Accuracy (≥5 g sample) | ±0.01% |
| Temperature Range | 30–200 °C |
| Sample Pan Diameter | φ90 mm |
| Display | High-Contrast LCD |
| Measurement Modes | Standard / Timed / Custom |
| Heating Profiles | Standard / Gradual / Step / Rapid |
| Predefined Methods | 100 templates |
| Stored Programs | Up to 300 |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported |
| Model | MX-50 |
| Heating Method | Halogen Lamp (400 W, Straight-Tube) |
| Moisture Range Display Resolution | 0.01% / 0.1% |
| Max Sample Capacity | 51 g |
| Weighing Accuracy | 0.001 g |
| Drying Temperature Range | 50–200 °C |
| Communication Interface | RS-232C |
| Compliance | GLP/GMP/ISO 9001-ready |
| Calibration Standard | Sodium Tartrate Dihydrate (15.66 ± 0.2 % w/w H₂O) |
| Brand | A&D |
|---|---|
| Model | MX-50 |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 51 g |
| Readability | 0.001 g |
| Moisture Content Resolution | 0.01 % / 0.1 % |
| Temperature Range | 50–200 °C |
| Display | Fluorescent LCD |
| Interface | RS-232 |
| Compliance | GLP/GMP/ISO |
| Software | WinCT-Moisture (PC-Connected) |
| Sample Compatibility | Solids, Powders, Granules, Pastes, Liquids |
| Calibration Standard | Disodium Tartrate Dihydrate (15.66 % ± 0.3/−0.1 % H₂O) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | RTF Series |
| Load Capacity Range | 1 kN to 50 kN |
| Load Accuracy | ±0.5% of reading |
| Crosshead Speed Range | 0.0005–1000 mm/min |
| Speed Accuracy | ±0.1% |
| Sampling Interval | 1 ms |
| Load Frame Rigidity Increase | 30% vs. prior generation |
| Drive System | Brushless digital servo motor with closed-loop microcomputer control |
| Force Sensor | ORIENTEC high-precision transducer |
| Lead Screw | High-accuracy backlash-free ball screw |
| Input Channels | Up to 13 analog/digital signal inputs |
| Compliance | Meets JIS B 7721 Class 0.5 (equivalent to ISO 7500-1 Class 0.5 and ASTM E4) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Type | Electromechanical Universal Testing Machine |
| Model | RTF |
| Load Accuracy | ±0.5% of reading (1/1 to 1/500 full scale) |
| Sampling Rate | 1 ms |
| Input Channels | Up to 13 |
| Drive System | Brushless AC servo motor with vector control |
| Transmission | Preloaded precision ball screw |
| Load Cell | ORIENTEC high-accuracy strain-gauge sensor |
| Frame Rigidity | Enhanced by 30% vs. prior generation |
| Optional | Full-color capacitive touchscreen HMI |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | RTF-2 Series |
| Load Capacity Range | 25 kN – 300 kN |
| Crosshead Speed Range | 0.0005 – 1000 mm/min |
| Speed Accuracy | ±0.2% |
| Load Measurement Accuracy | ±0.5% of reading (Class 0.5) |
| Sampling Rate | 1 ms |
| Input Channels | up to 13 |
| Control System | Closed-loop microcomputer-controlled brushless digital servo |
| Safety Features | Overload protection,行程 limit switches, sampling interruption |
| Calibration | One-touch automatic range calibration |
| Structural Rigidity | 30% higher than previous generation |
| Actuation | High-precision backlash-free ball screw |
| Force Sensor | ORIENTEC high-accuracy transducer |
| Optional | Full-color touch-screen interface |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | RTF-2325 / RTF-2430 / RTF-1325 |
| Accuracy Class | 0.5 |
| Load Capacity Range | 1 kN to 300 kN |
| Test Width | 420 mm / 590 mm |
| Crosshead Speed | 0.0005–500 mm/min or 0.0005–1000 mm/min |
| Load Accuracy | ±0.5% of reading (standard), ±1% of reading (optional range) |
| Sampling Interval | 1 ms |
| Input Channels | Up to 13 |
| Display | Optional full-color capacitive touchscreen with real-time force-displacement curve plotting |
| Data Storage | ≥10 preconfigured test profiles with auto-save/resume on power cycle |
| Test Modes | Tensile, Compression, Flexural, Peel, Cyclic, Creep, Stress Relaxation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | RTG Series |
| Load Capacity Options | 1 kN, 2.5 kN, 5 kN, 10 kN |
| Crosshead Travel (Effective) | 580–775 mm |
| Crosshead Speed Range | 0.05–1000 mm/min |
| Speed Accuracy | ±0.2% |
| Load Measurement Accuracy | ±1% of reading |
| Sampling Interval | 1 ms |
| Input Channels | up to 13 |
| Load Cell | ORIENTEC high-precision sensor |
| Drive System | Closed-loop microcomputer-controlled brushless digital servo motor |
| Transmission | High-precision backlash-free ball screw |
| Safety Features | Overload protection, dual-limit travel stops, sampling interruption |
| Calibration | One-touch automatic range calibration |
| Compliance | JIS B 7721, ISO 7500-1 Class 1, ASTM E4, ASTM D638, ASTM D3039, USP <1041>, GLP-compliant data traceability (with optional software) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | RV-10000A |
| Instrument Category | Vibrational Rheometer |
| Sample State | Liquid |
| Sample Viscosity Range | 0.3–25,000 mPa·s |
| Operating Frequency | 30 Hz |
| Vibration Amplitude | <1 mm |
| Repeatability | ±1% of full-scale reading |
| Temperature Control | Compatible with AX-SV-37 Circulating Bath |
| Sensor Material | Titanium-coated |
| Data Output | CSV (viscosity, temperature, shear stress) and JPEG plots to USB drive |
| Calibration | User-performed with deionized water reference |
| Measurement Stabilization Time | ≤20 s |
| Shear Rate Adjustment | Via programmable amplitude control |
| Compliance | Designed for GLP-compliant environments |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SJ-3000WP |
| Price Range | USD 1–4,999 |
| IP Rating | IP67 |
| Max Capacity | 3 kg |
| Readability | 0.0001 kg (0.1 g) |
| Pan Dimensions | 232 mm W × 192 mm D |
| Overall Dimensions | 236 mm W × 260 mm D × 148 mm H |
| Net Weight | ~4 kg |
| Power | 6 × AA batteries (up to 5,000 hrs with display & backlight off) |
| Display | Backlit LCD (character height: 26 mm) |
| Weighing Units | g, kg, lb, oz, ozt, lb-oz, tael, tola, N |
| Features | Auto-tare, auto-off, overload protection, counting mode, color-coded 5-step status indicator, touch-sensitive keypad, SUS304 stainless steel pan, sensor suspended within pan support structure |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Product Type | Imported Precision Balance |
| Model | SK-1000WP |
| Max Capacity | 1000 g |
| Readability | 0.5 g |
| Repeatability | ±0.5 g |
| Calibration | External |
| Protection Rating | IP65 |
| Power Supply | 6 × D-cell batteries (approx. 200 h operation) or optional AC adapter |
| Display | High-contrast LCD with stability indicator, net weight mode, and low-battery warning |
| Construction | Stainless steel arched housing and weighing pan |
| Compliance | Designed for GLP/GMP environments requiring washdown-capable instrumentation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | STB Series |
| Type | Electronic Tensile Testing Machine |
| Max Load Capacity | 2.5 kN |
| Effective Travel | 850 mm (STB-1225L) / 550 mm (STB-1225S) |
| Crosshead Speed Range | 0.05–1000 mm/min |
| Speed Resolution | 0.01 mm/min |
| Speed Accuracy | ±0.5% |
| Load Measurement Accuracy | ±1% of reading (within 1/1 to 1/500 of sensor rated capacity) |
| Automatic Load Range Switching | Up to 128× |
| Load Calibration | One-touch, integrated sensor-based calibration with built-in load cell identification |
| Overload Protection | Dual-mode — electronic cut-off detection + mechanical travel limiters (upper/lower) |
| Position Resolution | 0.001 mm (≤10 mm), 0.01 mm (>10 mm) |
| Display | 6-digit digital crosshead position readout |
| Power Supply | AC 100 V, 1φ, 50/60 Hz, 350 VA |
| Operating Environment | 5–40 °C, 20–80 % RH |
| Dimensions (L×H×W) | 470 × 1450 × 335 mm (L-type), 470 × 1050 × 335 mm (S-type) |
| Weight | 56 kg (L), 43 kg (S) |
| Energy Saving | 30% reduced standby power consumption |
| Data Acquisition Rate | 0.2 ms (with TACT interface) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | STB-1225L / STB-1225S |
| Max Load | 2.5 kN |
| Effective Stroke | 850 mm (STB-1225L) / 550 mm (STB-1225S) |
| Crosshead Speed Range | 0.05–1000 mm/min |
| Speed Resolution | 0.01 mm/min |
| Speed Accuracy | ±0.5% |
| Load Accuracy | ±1% of reading (within 1/1 to 1/500 of sensor rated capacity) |
| Auto Range Switching | up to 128× |
| Load Calibration | one-button sensor-integrated calibration with sensor identification |
| Overload Protection | yes |
| Travel Limiters | dual (upper/lower) |
| Dimensions (L×H×W) | 470×1450×335 mm (L) / 470×1050×335 mm (S) |
| Weight | 56 kg (L) / 43 kg (S) |
| Power Supply | AC 100 V, 1Φ, 50/60 Hz, 350 VA |
| Operating Environment | 5–40 °C, 20–80 %RH |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SV-10 |
| Instrument Type | Oscillatory Viscometer |
| Mounting Style | Benchtop Fixed |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 0.3 mPa·s to 10 Pa·s |
| Temperature Range | 0–160 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1 °C/min |
| Vibration Frequency | 30 Hz |
| Amplitude | 1 mm |
| Repeatability | ±1% of reading (std. dev.) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SV-1A |
| Instrument Type | Handheld |
| Flow Rate | 0.1 ft³/min (2.83 L/min) |
| Particle Size Channels | 0.3 µm, 0.5 µm, 5.0 µm |
| Data Storage Capacity | 10,000 sample records |
| Power Supply | 4× AA Ni-MH rechargeable batteries (included) |
| Weight | 0.68 kg (1.5 lb) |
| Communication Interface | RS-232 / RS-485 |
| Compliance | ISO 21501-4, ISO 14644-1, JIS B 9921 |
| Warranty | 1 year |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SV10 / SV-100 |
| Measurement Principle | Sinusoidal fork vibration method (30 Hz) |
| Viscosity Range | SV10: 0.3–10,000 mPa·s |
| SV-100 | 1,000–100,000 mPa·s |
| Repeatability | ±1% of reading (full scale, SD, 20–30 °C, no condensation) |
| Minimum Sample Volume | 35 mL |
| Display | Fluorescent LCD (large-character, high-contrast) |
| Interface | RS-232C standard |
| Temperature Control Option | Compatible with external circulating water bath |
| Software | WinCT-Viscosity (RsVisco) included |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Construction | Titanium-coated vibrating fork sensor (corrosion-resistant, easy-clean) |
| Form Factor | Benchtop fixed-unit system |
| Operating Environment | Ambient temperature (15–35 °C), non-condensing |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4212A |
| Readability | 0.1 mg (high-sensitivity mode), 1 mg (standard mode) |
| Response Time | 0.8 s (1 mg), 1.1 s (0.1 mg) |
| Interface | RS-232C standard, optional Ethernet (AD-4212A-08), BCD output (AD-4212A-01), external trigger input |
| Output Signals | Three-level comparator (HI / OK / LO) with audible buzzer alarm |
| Power Management | Auto-on / auto-off function |
| Mechanical Options | Stainless steel draft shield (AD-4212A-19), metal leveling feet (AD-4212A-20), 3 m extension cable (AD-4212A-07) |
| Sensor Technology | SHS (Super Hybrid Sensor) |
| Separated Design | Weighing unit and display unit connected via detachable cable (standard 2 m, extendable up to 5 m) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4401 |
| Sampling Rate | 100 Hz |
| Internal A/D Resolution | 1:1,000,000 |
| Display Resolution | 1:16,000 |
| Input Sensitivity | 0.3 µV/d |
| IP Rating | IP65 |
| Communication Interfaces | RS-232 (current loop & optional voltage), RS-422/485 (up to 10 units daisy-chained), BCD, 4–20 mA analog output |
| Operating Modes | 8 configurable weighing and control modes |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4402 |
| Analog-to-Digital Conversion | 100 Hz sampling rate, internal resolution 1/1,000,000, display resolution 1/16,000, input sensitivity 0.3 µV/d |
| IP Rating | IP65 front panel |
| I/O Capacity | 11 inputs / 11 outputs (configurable across 50 functions) |
| Recipe Storage | 100 recipes |
| Material Database | 100 materials |
| Alarm Outputs | up to 8 fault signals |
| Communication Interfaces | RS-232, RS-422/485, parallel BCD, relay, analog output, CC-Link, DeviceNet, PROFIBUS (via optional interface boards) |
| Calibration | digital span calibration & gravity compensation (no weights required) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4971-E |
| Detection Sensitivity | Fe Ø0.3 mm / SUS Ø0.8 mm |
| Aperture Width | 350 mm |
| Aperture Height Options | 100 mm / 170 mm / 250 mm |
| Through-Height Options | 80 mm / 150 mm / 230 mm |
| Conveyor Belt Width | 250 mm |
| Conveyor Length | 800 mm |
| Display | 7-inch WVGA Color Touchscreen |
| IP Rating | IP65 |
| Communication | Standard Modbus RTU/TCP |
| Data Export | Ethernet + USB (PDF/Chart) |
| Product Memory | 1,000 Recipes |
| Construction | Stainless Steel Frame |
| Drive Mechanism | Direct Gear Drive |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Company, Ltd. |
| Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Calibration | Internal Automatic Calibration |
| Compliance | GLP/GMP/GCP/ISO-compliant data output |
| Display | 5-inch full-color capacitive touchscreen (BH-T series) |
| Draft Shield | Motorized auto-sensing infrared door with seamless flush design |
| Electrostatic Control | External DC ionizer (optional, BH-T model) |
| Weighing Pan | Perforated anti-convection pan (φ90 mm) |
| Stabilization Time | ≤3 s |
| Operating Environment | 15–30 °C, 20–80% RH (non-condensing) |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Features | Built-in daily/periodic performance verification, minimum weight auto-detection per USP <41> & ChP 2025, user-defined print formats, audit trail, role-based access control |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | GR-300 / GR-202 / GR-200 / GR-120 |
| Capacity | 120–310 g |
| Readability | 0.01–0.1 mg |
| Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 249 × 330 × 328 mm |
| Weight | ~6.0 kg |
| Calibration | Internal motorized砝码, one-touch auto-calibration |
| Environmental Compensation | Automatic temperature & drift correction |
| Interface | RS-232 standard |
| Compliance | GLP, GMP, GCP, ISO/IEC 17025 |
| Software | WinCT Data Acquisition Suite |