Adam
Filter
Showing all 17 results
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABW-S |
| Price Range | USD 2,400 – 2,700 |
| IP Rating | IP68 |
| Construction | 304 Stainless Steel Housing |
| Power Supply | 12 VDC 800 mA Adapter + Internal Rechargeable Battery |
| Battery Life | Up to 80 hours |
| Display | Dual LED — Front (20 mm digit height), Rear (15 mm digit height) |
| Weighing Units | kg, g, lb, oz, lb:oz |
| Internal Counting Resolution | 1:600,000 |
| Overload Protection | Yes |
| Operating Temperature | 0 °C to 40 °C |
| Calibration Method | External Calibration Only |
| Counting Mode | Auto-part-weight optimization with dynamic averaging |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment Ltd. |
| Type | Imported |
| Model | AVT |
| Dimensions (W×D×H) | 600 × 800 × 787 mm |
| Total Weight | 63 kg |
| Granite Top Dimensions (W×D×H) | 400 × 450 × 70 mm |
| Granite Weight | 44 kg |
| Granite Surface Finish | Precision-Lapped, Flatness ≤ ±5 µm over 400 × 450 mm |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CQT-2601 |
| Instrument Type | Precision Balance |
| Maximum Capacity | 2600 g |
| Readability | 0.1 g |
| Repeatability | ±0.1 g |
| Linearity Error | ±0.2 g |
| Calibration Method | External Calibration |
| Calibration Weight Required | 2000 g |
| Display | 6-digit, 15 mm high backlit LCD |
| Stabilization Time | 3 s |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 12 V AC @ 150 mA adapter or 6 × AA batteries (optional) |
| Weighing Units | kg, g, lb, oz, ct, dr, GN |
| Pan Diameter | 145 mm |
| Draft Shield Dimensions (L×W×H) | 180 × 158 × 82 mm |
| Housing Material | Matte-finish ABS |
| Overall Dimensions (L×W×H) | 195 × 240 × 70 mm |
| Shock Protection | ShockProtect™ technology (withstands up to 180 kg overload) |
| Security | Bottom-mounted Kensington lock slot |
| Protection Class | IP42-rated enclosure (dust and splash resistant) |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EAB Series |
| Instrument Type | Analytical Balance |
| Capacity Range | 200–500 g |
| Readability | 0.01 mg / 0.1 mg |
| Maximum Capacity | 510 g |
| Repeatability | 0.02 mg |
| Calibration | Fully Automatic Internal Calibration and Optional External Calibration |
| Compliance | GLP-Compliant Data Logging, ISO/IEC 17025 Supportable, ASTM E898-22 Referenced Procedures |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LBX |
| Price Range | USD 1 – 4,999 |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LPB |
| Instrument Type | Precision Balance |
| Capacity Range | 500–1000 g |
| Readability | 0.001 g |
| Calibration | Internal or External |
| Maximum Capacity | 820 g |
| Measurement Accuracy | 0.001 g |
| Repeatability | 0.002 g |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LTB |
| Instrument Type | Precision Balance |
| Capacity Range | 2000–5000 g |
| Maximum Capacity | 6000 g |
| Readability | 0.01 g |
| Calibration | Internal or External |
| Repeatability | 0.02 g |
| Linearity Error (±) | 0.03 g |
| Minimum Weight | 20 g |
| Stabilization Time | 2 s |
| Display | Backlit LCD with 24 mm high white digits on black background |
| Weighing Units | g, kg, ct, GN, N, dr, lb, oz, lb:oz, ozt, dwt, tl.T, tl.H, tl.S, T, Custom |
| Interface | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 185 × 185 mm |
| Dimensions (W × D × H) | 224 × 374 × 95 mm |
| Net Weight (Internal Calibration Models) | 5.9 kg |
| Net Weight (External Calibration Models) | 4.5 kg |
| Functions | Weighing, Piece Counting, Percentage Weighing, Checkweighing, Check Counting, Animal/Dynamic Weighing, Density Determination, Net/Gross Weighing, Display Hold, Peak Hold |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment Ltd. |
| Product Type | Imported Precision Balance |
| Model | LBB |
| Instrument Category | Precision Balance |
| Maximum Capacity | 15,000 g |
| Readability | 0.1 g |
| Calibration Method | External Calibration |
| Repeatability | 0.2 g |
| Linearity Error (±) | 0.3 g |
| Minimum Weight | 200 g |
| Stabilization Time | 2 s |
| Weighing Units | g, kg, ct, GN, N, dr, lb, oz, lb:oz, ozt, dwt, tl.T, tl.H, tl.S, T, Custom Units |
| Interfaces | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Display | Backlit LCD with 24 mm high white digits on black background |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 185 × 185 mm |
| Dimensions (W × D × H) | 224 × 374 × 95 mm |
| Net Weight | 4.5 kg |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment (UK) |
| Product Type | Analytical Balance |
| Model | LAB Series (e.g., LAB 214i, LAB 254e) |
| Maximum Capacity | 250 g |
| Readability | 0.0001 g |
| Repeatability | ±0.0002 g |
| Linearity Error | ±0.0003 g |
| Minimum Weight | 200 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (i-models) or External (e-models) |
| Display | Backlit LCD, 24 mm digit height |
| Weighing Units | g, mg, ct, GN, N, dr, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, user-defined |
| Interfaces | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 90 mm diameter |
| Draft Shield | Standard tempered glass square shield (192 × 195 × 230 mm W×D×H) |
| Dimensions (W×D×H) | 224 × 374 × 338 mm |
| Net Weight | 6.2 kg (i-models), 5.8 kg (e-models) |
| Compliance | GLP-compliant data logging, ISO/IEC 17025 support, USP Chapter 41 & 1251 compatible |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MUW |
| Price Range | USD 1,400 – 4,200 |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DDK |
| Instrument Type | Analytical Balance-Compatible Density Kit |
| Balance Compatibility | Adam NBL Series Balances Only |
| Maximum Load Capacity (with NBL balance) | 800 g |
| Mass Readability | 0.0001 g (0.1 mg) / 0.001 g (1 mg) |
| Repeatability | ±0.0001 g / ±0.001 g |
| Calibration | Internal Automatic or Manual Calibration Supported |
| Density Measurement Range | Solid & Liquid Samples |
| Measurement Principle | Archimedean Buoyancy Method (ASTM D792, ISO 1183, USP <841>) |
| Brand | Adam |
|---|---|
| Origin | UK |
| Manufacturer | Adam Equipment |
| Model | NBL / NBL-p |
| Capacity | 2000–5000 g (up to 32,000 g) |
| Readability | 0.1 g |
| Internal Resolution | 0.00001 g (10 µg) |
| Repeatability | ±0.2 g |
| Linearity Error | ±0.4 g |
| Operating Temperature | 0–40 °C |
| Power Supply | 12 V DC, 50/60 Hz, 800 mA |
| Display | Backlit LCD (digit height 20 mm) |
| Weighing Pan | 304 Stainless Steel (400 × 300 mm) |
| Dimensions (W×D×H) | 401 × 460 × 102 mm (base), column: 401 × 500 × 600 mm |
| Net Weight | 4.5–7.3 kg |
| Communication | USB + bidirectional RS-232 |
| Weighing Modes | Standard, Net/Gross, Checkweighing, Percentage, Piece Counting, Animal/Dynamic, Density, Below-Balance |
| Brand | Adam |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMB |
| Pricing | Available Upon Request |
| Capacity | 50 g / 200 g |
| Readability | 0.001 g / 0.01 % (PMB 53) |
| Repeatability (S.D.) | 0.005 g / 0.05 % (10 g sample, PMB 53) |
| Pan Diameter | Ø90 mm |
| Heating Range | 50–160 °C |
| Max. Test Duration | 99 minutes |
| Heating Source | 400 W Halogen Lamp |
| Heating Modes | Ramp, Step, Standard |
| Stabilization Time | 2–3 s |
| Display | Dual-line LED backlight with range-tracking indicator |
| Interfaces | USB Host, USB I/O, RS-232 |
| Internal Memory | 99 test results, 49 test methods |
| External Storage | USB flash drive support |
| Calibration | External calibration only |
| Power Supply | 110/220 V, 50/60 Hz |
| Operating Temperature | 0–40 °C |
| Dimensions (W×D×H) | 360 × 250 × 185 mm |
| Net Weight | 6 kg |
| Languages | English, German, French, Spanish |
| Units | g, % liquid, % solid, ATRO % M (moisture on dry basis), ATRO % S (solids on dry basis) |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PMB |
| Heating Source | Halogen Lamp (400 W) |
| Measurement Principle | Thermogravimetric Analysis (TGA) via Halogen-Heated Infrared Drying |
| Display Modes | %Moisture, %Solids, %Moisture/Dry Weight, %Solids/Dry Weight |
| Termination Methods | Manual Stop, Timer-Based Auto-Stop, Stability-Based Auto-Stop |
| Max Test Duration | 99 min |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Profiles | Standard, Step, Ramp |
| Calibration | External Weighing Calibration |
| Data Storage | 99 test results + 49 user-defined methods + 1 factory preset |
| Interface Options | RS-232, USB Serial, USB Host (for flash drive logging) |
| Language Support | English, French, German, Spanish |
| Date Format Options | YMD, DMY, MDY |
| Audible Alert | Configurable end-of-test beep |
| Weighing Platform Diameter | 90 mm |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SAB |
| Instrument Type | Analytical Balance |
| Capacity Range | 200–500 g |
| Readability | 0.01 mg (10 µg) / 0.1 mg (100 µg) |
| Calibration | Internal Automatic Calibration & External Calibration |
| Maximum Capacity | 510 g |
| Repeatability | 0.02 mg |
| Display | 15 mm high graphic LCD |
| Interface | RS-232 |
| Operating Temperature | 10–30 °C |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Net Weight | 6.7–7.0 kg |
| Dimensions (W×D×H) | 224 × 374 × 338 mm |
| Pan Size | 80 mm diameter |
| Draft Shield | Standard glass square draft shield (192 × 195 × 230 mm) |
| Housing Material | ABS plastic |
| Compliance | GLP-compliant data logging, password protection, audit-ready timestamped output |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPB363i / SPB723i / SPB1203i / SPB2103i (Internal Calibration) / SPB363e / SPB723e (External Calibration) |
| Weighing Capacity | 360 g – 2100 g |
| Readability | 0.001 g |
| Repeatability | ±0.002 g |
| Linearity Error | ±0.003 g to ±0.005 g |
| Stabilization Time | ≤3 s |
| Calibration | Internal (i-series) or External (e-series) |
| Display | 15-mm-high graphical LCD |
| Pan Size | 110 mm diameter |
| Draft Shield | Standard tempered glass square shield (192 × 195 × 115 mm, W×D×H) |
| Housing Material | ABS plastic |
| Dimensions (W×D×H) | 224 × 374 × 219 mm |
| Net Weight | 6.4 kg (i-series), 6.7 kg (e-series) |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Operating Temperature | 10 °C – 30 °C |
| Connectivity | RS-232 |
| Weighing Units | g, mg, ct, GN, lb, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, user-defined |
| Compliance | GLP-compliant data logging (date/time stamp), password protection, audit-ready operation |
| Brand | Adam |
|---|---|
| Origin | UK |
| Manufacturer | Adam Equipment |
| Type | Precision Balance |
| Model | STB |
| Capacity | 3200–8200 g |
| Readability | 0.01 g |
| Repeatability | ±0.02 g |
| Linearity Error | ±0.03–0.04 g |
| Stabilization Time | 3 s |
| Calibration | Internal (i-models) or External (e-models) |
| Display | 15 mm high graphical LCD |
| Weighing Units | g, mg, ct, GN, lb, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, custom |
| Interface | RS-232 |
| Operating Temperature | 10–30 °C |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Pan Size | 185 × 185 mm |
| Dimensions (W×D×H) | 224 × 374 × 95 mm |
| Net Weight | 6.4 kg (i), 6.7 kg (e) |
| Construction | ABS housing, 304 stainless steel pan |
| Compliance | GLP-compliant data logging, password protection, audit-ready timestamped printouts |
