ADC Bio
Filter
Showing all 15 results
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | ACE |
| Configuration | Master Control Unit + Up to 30 ACE Sensor Nodes |
| Power | Low-Voltage DC via Single Cable (No Pneumatic Tubing) |
| Max Network Radius | 200 m |
| Compliance | Designed for GLP-Compliant Field Deployment |
| Data Storage | Internal SD Card (No PC Required) |
| Interface | Local LCD + Keypad on Both Master and ACE Units |
| Optional Modules | O₂ Sensor, Hyperspectral Imaging Module, Thermal IR Imaging Module, ECODRONE® UAV Integration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | ACE |
| Instrument Type | Multi-parameter Soil Respiration Analyzer |
| CO₂ Measurement Range | 0–896 ppm |
| Resolution | 1 ppm |
| Accuracy | ±1% of reading |
| IRGA Drift | ≤0.6% per 24 h |
| PAR Sensor | 0–3000 µmol m⁻² s⁻¹ (Silicon Photodiode) |
| Soil Temperature Range | −20 to +50 °C |
| Soil Moisture (SM300) | 0–100 vol%, ±3% (soil-calibrated) |
| Soil Moisture (Theta Probe) | 0–1.0 m³·m⁻³, ±1% (factory-calibrated) |
| Flow Control | 200–5000 mL/min (±3% accuracy) |
| Chamber Volumes | Closed-mode 2.6 L, Open-mode 1.0 L |
| Chamber Diameter | 23 cm |
| Power Supply | 12 V DC, 40 Ah battery (28 days continuous operation) |
| Data Storage | 1 GB CompactFlash card (up to 4 million records) |
| Communication | RS-232 (up to 19200 baud), rugged 3-pin waterproof connector |
| Display | 240 × 64 pixel LCD |
| Dimensions (H×W×D) | 82 × 33 × 13 cm |
| Weight | 7.0 kg |
| Network Capacity | Up to 30 units within 200 m radius |
| Operating Modes | Closed-chamber and open-path configurable |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | ACE Automated Soil Respiration System |
| CO₂ Analyzer Resolution | 1 ppm |
| Chamber Area | 415 cm² |
| Power Options | 12 V 40 Ah Rechargeable Battery (≈30 days field operation), Solar Panel, or 220 V AC |
| Sensor Expansion | Up to 6 soil temperature probes, 4 soil moisture sensors |
| Measurement Modes | Closed-chamber (transparent & opaque), Open-chamber (transparent & opaque) |
| Data Storage | Internal SD card |
| Operating Interface | 240×64 pixel LCD with 5-button microcontroller interface |
| Optional Modules | Soil O₂ sensor, Hyperspectral imaging module, IR thermal imaging module, ECODRONE® UAV integration kit, Custom gas extraction/sampling configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | AM-350 |
| Measurement Width | 103 mm |
| Maximum Sample Length | 2 m |
| Scanning Speed | up to 20 mm/sec |
| Linear Accuracy | ±1% |
| Area Accuracy | ±2% |
| Perimeter Accuracy | ±5% |
| Resolution | 0.065 mm² |
| Memory | 256 KB RAM (stores up to 2,000 datasets) |
| Display | 64 × 240 pixel LCD |
| Rechargeable Battery | 12 V, 1.2 Ah (enables ~3,000 field scans) |
| Operating Temperature | 0–45 °C |
| Dimensions | 275 × 250 × 30 mm |
| Weight | 1.8 kg |
| Output Formats | BMP, TIFF |
| Interface | USB |
| Measured Parameters | leaf area, cumulative area, mean area, diseased area, length, width, perimeter, length-to-width ratio, shape factor (4πA/P², where A = area, P = perimeter) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AM350 Portable Leaf Area Meter |
| Price | Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | APS Multi-Channel |
| Configuration Options | 5-channel or 10-channel modular system |
| Gas Exchange Measurement Principle | Infrared Gas Analysis (IRGA) with integrated multi-port gas multiplexer |
| Leaf Chamber Interface | Detachable, independently controlled cuvettes connected via extended pneumatic tubing and signal cables |
| Compliance | Designed for GLP-compliant environmental physiology studies |
| Software Platform | APS Control Suite with audit trail, timestamped raw data export (CSV/NetCDF), and optional FDA 21 CFR Part 11–ready configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | EGA60 |
| CO₂ Measurement Range | 0–2000 ppm |
| H₂O Vapor Pressure Range | 0–75 mbar |
| O₂ Measurement (Optional) | 0–50% (0–23 mg/L) |
| Flow Rate per Channel | 0–500 mL/min |
| Resolution | CO₂ = 1 ppm, H₂O = 0.1 mbar, O₂ = 0.05% @ 20% O₂ |
| Accuracy | CO₂ (temperature & pressure compensated), O₂ = ±0.2% @ 20% O₂ |
| Response Time (O₂) | <1 s |
| Data Storage | Removable SD card (up to 16 million data points) |
| Display | 240 × 64 pixel monochrome LCD |
| Operating Temperature | 5–45 °C |
| Dimensions | 27 × 25 × 15 cm |
| Weight | 7.5 kg |
| Interfaces | RS232, USB Mini-B, 7-channel analog input (0–5 V / 0–20 mA) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | iFL Portable |
| Pricing | Available Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi T |
| CO₂ Range | 0–2000 ppm (0.1 ppm resolution, ±1% accuracy, 0.25 s response) |
| H₂O Range | 0–75 mbar (0.1 mbar resolution, 0.5% RH repeatability) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (silicon photodiode, ±5 µmol·m⁻²·s⁻¹) |
| LED Light Sources | RGB (0–2400 µmol·m⁻²·s⁻¹) or White (0–2500 µmol·m⁻²·s⁻¹) |
| Leaf Chamber Temp | −5 to 50 °C (±0.2 °C) |
| Airflow | 100–500 mL/min (±2% FS) |
| Battery Life | ~10 h (12 V, 2.8 Ah sealed lead-acid) |
| Weight | 2.4 kg (main unit), 0.6 kg (standard chamber) |
| Dimensions | 240 × 125 × 140 mm (unit) |
| Data Storage | Removable SD card (up to 32 GB) |
| Compliance | ASTM E2912-13 (gas exchange instrumentation), ISO 17025 traceable calibration protocols, GLP-compliant data logging with timestamp, GPS geotagging (latitude/longitude/elevation) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi-T |
| CO₂ Measurement Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf & Chamber Temperature Range | −5 to 50 °C |
| Accuracy | ±0.2 °C |
| Airflow Rate | 68–340 mL/min |
| Flow Accuracy | ±2% of full scale |
| Preheat Time | 5 min at 20 °C |
| Data Storage | SD card (up to 32 GB, 16 million data points) |
| Display | 480 × 272-pixel color WQVGA touchscreen (95 × 53.9 mm) |
| Weight | 2.4 kg |
| Dimensions | 240 × 125 × 140 mm |
| Battery Life | ~10 h (12 V / 2.8 Ah lead-acid) |
| Operating Environment | 5–45 °C |
| GPS | Integrated |
| IRGA Type | Differential open-path, auto-zeroing with pressure & temperature compensation |
| H₂O Sensor | Dual-laser tunable diode absorption spectroscopy (TDLAS) |
| Fluorescence Module (optional) | Supports F₀, Fₘ, Fₘ′, QY_Ln, NPQ, OJIP-test (26 parameters), 100 kHz sampling rate |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Intelligent Photosynthesis System |
| CO₂ Range | 0–2000 ppm |
| H₂O Control Range | 0–75 mbar |
| PAR Source | Adjustable RGB or White LED (0–2400 µmol·m⁻²·s⁻¹) |
| Temperature Control | Peltier-based (ΔT = +15 °C / −10 °C vs. ambient or ambient-follow mode) |
| GPS | Integrated with UTC time, latitude/longitude, and altitude logging |
| Humidity Sensors | Dual high-precision laser-trimmed capacitive sensors |
| IRGA Design | Gold-coated, miniaturized, time-domain differential dual-beam NDIR for drift-free CO₂ measurement |
| Leaf Chamber Climate Control | Simultaneous closed-loop regulation of CO₂, H₂O, PAR, and temperature |
| Battery Life | Up to 16 h (Li-ion) |
| Weight | Control Unit 4.1 kg, Measurement Unit 0.8 kg |
| Data Storage | SD card + USB interface |
| Fluorescence Integration | Direct hardware synchronization with FluorCam and portable chlorophyll fluorometers |
| Compliance | Designed for GLP-aligned field data acquisition |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Portable Photosynthesis System |
| CO₂ Measurement Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected) |
| Leaf/Chamber Temperature Range | −5 to 50 °C (±0.2 °C accuracy) |
| Airflow Rate | 100–500 mL·min⁻¹ |
| CO₂ Control | Up to 2000 ppm via internal supply |
| H₂O Control | Humidity adjustable above/below ambient |
| Temperature Control | Peltier-based, ±15 °C offset from ambient |
| PAR Control | White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Weight | 4.1 kg (main unit), 0.8 kg (handheld sensor handle) |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Display | 95 × 53.9 mm WQVGA color touchscreen (80 × 272 px) |
| Data Storage | Removable SD card (up to 32 GB) |
| Communication | Mini-B USB + RS232 (max. 230,400 baud) |
| Operating Environment | 5–45 °C, high-humidity/dusty conditions supported |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T |
| CO₂ Measurement Range | 0–3000 ppm (±1% accuracy, 0.1 ppm resolution, dual-beam IRGA) |
| H₂O Measurement Range | 0–75 mbar (0.1 mbar resolution, dual-laser tunable hygrometer) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected Si photodiode, ±5 µmol·m⁻²·s⁻¹) |
| Leaf & Chamber Temperature | −5 to 50 °C (±0.2 °C) |
| Air Flow Rate | 100–500 mL·min⁻¹ (±2% FS) |
| Response Time (CO₂) | 0.25 s |
| Auto-Zero Cycle | 4 s |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Weight | 4.1 kg (main unit), 0.8 kg (handle) |
| Dimensions | 230 × 110 × 170 mm (unit), 300 × 80 × 75 mm (handle) |
| Data Storage | Removable SD card (up to 32 GB) |
| Environmental Operating Range | 5–45 °C |
| Optional Leaf Chambers | Broadleaf (6.25 cm²), Narrowleaf (5.2 cm²), Conifer (175 cm³), Arabidopsis/Small-Leaf (16 mm Ø), Mini-Canopy (≤55 mm height), Whole-Plant Arabidopsis, Fruit Chamber (1 L), Soil Respiration Chamber (1 L), Fluorescence Adapter (compatible with OS-5p) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | SRS-1000 T |
| CO₂ Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Sensor Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Soil Temperature Probe Range | 5–50 °C |
| Chamber Volume | 1 L |
| Chamber Diameter | 130 mm |
| Stainless Steel Collar Height | 75 mm |
| Acrylic Chamber Height | 70 mm |
| Operating Temperature | 5–45 °C |
| Battery Life | 10 h (2.8 Ah, 12 V lead-acid) |
| Display | 480 × 272 pixel WQVGA color touchscreen (95 × 53.9 mm) |
| Data Storage | SD card (up to 32 GB) |
| Interface | Mini-B USB & RS232 (9-pin D-sub) |
| Flow Rate | 68–340 µmol·m⁻²·s⁻¹ |
| Warm-up Time | 5 min @ 20 °C |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | SRS-2000 T |
| CO₂ Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Sensor Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Soil Temperature Probe Range | 5–50 °C |
| Chamber Volume | 1 L |
| Chamber Diameter | 130 mm |
| Chamber Height (Stainless Steel Ring + Acrylic Hood) | 145 mm |
| Flow Rate | 68–340 µmol·m⁻²·s⁻¹ |
| Preheat Time | 5 min @ 20 °C |
| Display | 480 × 272-pixel WQVGA color touchscreen (95 × 53.9 mm) |
| Battery | 7.5 Ah / 12 V Li-ion (16 h continuous operation) |
| Data Storage | SD card (up to 32 GB) |
| Operating Temperature | 5–45 °C |
| Control Unit Dimensions & Weight | 230 × 110 × 170 mm / 4.1 kg |
| Handle Weight | 0.8 kg |
| Chamber Weight | 645 g (325 g ring + 320 g hood) |