ADOLF KUHNER
Filter
Showing all 3 results
| Brand | ADOLF KUHNER |
|---|---|
| Origin | Switzerland |
| Model | ISF1-Z |
| Instrument Type | Temperature-Controlled Orbital Shaking Incubator |
| Drive System | Direct-Drive DC Motor |
| Speed Range | 20–500 rpm (up to 700 rpm optional at select amplitudes) |
| Adjustable Amplitude | 3 / 6 / 9 / 12.5 / 19 / 25 / 50 / 70 mm (0–70 mm, continuously variable) |
| Temperature Range | Ambient +10°C to 80°C (lower limit down to –5°C with Peltier or compressor cooling) |
| Temperature Uniformity | < ±0.2°C at 37°C |
| Chamber Volume | 378 L |
| Chamber Material | Electropolished Stainless Steel (AISI 316L) |
| Humidity Control (optional) | 50–85% r.H. (EcoDew® system) |
| CO₂ Control (optional) | 0–20% v/v, IR sensor, ±0.4% abs accuracy at 5% CO₂ |
| Interface | Standard CAN-Bus |
| Power Supply | 230 V AC, 50/60 Hz |
| Max. Power Consumption | ~1000 W |
| Dimensions (L×D×H) | 1288 × 859 × 771 mm |
| Weight | 200–225 kg (model-dependent) |
| Brand | ADOLF KUHNER |
|---|---|
| Origin | Switzerland |
| Model | ISF4-X |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Speed Range | 20–500 rpm |
| Temperature Range | Ambient +10°C to 80°C (or –10°C to 80°C with compressor option) |
| Temperature Uniformity | ±0.3°C (at 37°C, across full shaker tray) |
| Chamber Volume | 1272 L |
| Power Consumption | <1700 W (standard), <2000–2600 W (with compressor & humidity) |
| Tray Dimensions | 800 × 420 mm |
| Max Load per Tray | 25 kg |
| Orbit Diameters | Ø12.5 mm, Ø25.0 mm, Ø50.0 mm (circular) |
| CO₂ Control | Optional (0–20% vol, NDIR sensor, ±0.4% accuracy at 5%) |
| Humidity Control | Optional (up to 85% r.h., capacitive sensor, ±2% r.h.) |
| Interface | CAN-bus (standard), USB/Ethernet (optional) |
| Lighting | 2 fluorescent lamps |
| Operating Languages | DE/FR/IT/EN/ES |
| Ambient Temp Range | 10–35°C |
| Brand | ADOLF KUHNER |
|---|---|
| Origin | Switzerland |
| Model | LT-X/XC |
| Instrument Type | Temperature-Controlled Orbital/Linear Shaking Incubator |
| Speed Range | 20–500 rpm |
| Speed Accuracy | ±0.5 rpm |
| Temperature Range | Ambient +10 °C to 80 °C (LT-XC: 5–60 °C with enhanced stability) |
| Chamber Volume | 260 L |
| Drive System | Brushless Magnetic Direct Drive |
| Oscillation Modes | Orbital (Ø12.5 / 25.0 / 50.0 mm), Linear (12.5 / 25.0 / 50.0 mm) |
| Temperature Uniformity | ±0.25 °C at 37 °C (across tray, LT-XC variant) |
| Humidity Control | Up to 85 % RH (optional) |
| CO₂ Control | 0–20 % (IR sensor, ±0.4 % accuracy at 5 % CO₂, standard on LT-XC) |
| O₂ Control | 0–20.9 % (zirconia sensor, optional) |
| Airflow | 160 m³/h |
| Power Supply | 220–240 V / 50–60 Hz |
| Weight | 170 kg |
| IP Rating | IP22 (splash-protected drive) |
| Warranty | 5-year manufacturer warranty |