Aeroqual
Filter
Showing all 11 results
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Instrument Type | Portable |
| Measurement Range (Low) | 0–0.5 ppm |
| Detection Limit (Low) | 1 ppb |
| Response Time (Low) | < 95 s |
| Measurement Range (High) | 0–10.00 ppm |
| Resolution (High) | 0.01 ppm |
| Response Time (High) | < 35 s |
| Leakage Probe Range | 0–50.00 ppm (up to 100 ppm) |
| Resolution (Leak) | 0.01 ppm |
| Response Time (Leak) | < 10 s |
| Sensor Technology | GSS (Gas Sensitive Semiconductor) with Built-in Compensation Algorithm |
| Operating Environment | –5 to 50 °C, 5–95% RH (non-condensing) |
| Sampling Method | Active pump-assisted aspiration |
| Optional Multi-gas Modules | VOC, CO, NH₃ |
| Brand | AeroQual |
|---|---|
| Model | AQM 60 |
| Measurement Principle | Electrochemical & Metal Oxide Semiconductor (MOS) Sensor Array |
| Gas Parameters | O₃, NO₂, CO, SO₂, CO₂, VOCs |
| Particulate Monitoring | PM₁₀ (optional PM₂.₅) |
| Meteorological Parameters | Temperature, Relative Humidity, Wind Speed, Wind Direction, Noise |
| Data Logging Interval | Configurable down to 2-minute sampling |
| Communication Interfaces | GSM/GPRS/UMTS modem, Ethernet (LAN/WLAN), RS232 |
| Calibration Traceability | NIST-traceable gas standards |
| Enclosure Rating | IP65-rated weatherproof housing |
| Onboard Storage | Internal flash memory (≥16 GB) |
| Power Supply | 12–24 V DC or solar-compatible |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQM 65 |
| Power Supply | 90–264 VAC, 47–63 Hz |
| Operating Temperature | −35 °C to +50 °C |
| Enclosure Rating | IP65 |
| Dimensions (standard) | 1310 × 510 × 290 mm (H×W×D) |
| Weight | ~25 kg |
| Core Computing Platform | Intel Atom N2600, 1.6 GHz, 2 GB RAM, 32 GB SSD, Ubuntu Linux |
| Communication | Wi-Fi, Ethernet (LAN), optional cellular GPRS modem |
| Gas Sampling | 12 V brushless diaphragm pump, PTFE-lined stainless steel inlet |
| Thermal Management | DC compressor (R134a), 12–24 V, 60 W resistive heater |
| Data Transmission | Aeroqual Cloud (encrypted), FTP/email export (optional), SMS/email alerts (optional) |
| Calibration Options | AirCal 1000 (portable), AirCal 8000 (integrated) |
| Certified Sensor Modules | Gill WindSonic (ultrasonic wind), Vaisala WXT536 (weather), Cirrus MK427 Class 1 (noise), Novalynx pyranometer (solar radiation) |
| Measured Gases | O₃ (0–0.5 ppm), NO₂ (0–0.2 ppm), NOₓ (0–0.5 ppm), CO (0–25 ppm), SO₂ (0–10 ppm), H₂S (0–10 ppm), CO₂ (0–2000 ppm), VOC (0–20 ppm) |
| Particulate Matter | PM₁/PM₂.₅/PM₁₀/TSP via optical particle counter (±5 µg/m³ + 15% of reading) and turbidimeter (±2 µg/m³ + 5% of reading) |
| Meteorological Parameters | Wind speed/direction, temperature, relative humidity, barometric pressure, rainfall, solar irradiance |
| Noise Monitoring | 30–100 dB(A), Class 1 accuracy per IEC 61672-1 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQM65 |
| Particle Detection | PM1, PM2.5, PM10, TSP (via turbidimetric & optical counting methods) |
| Gaseous Pollutants | O₃, NO₂, CO, SO₂, NOₓ, H₂S, CO₂, VOC (ppb–ppm range), CH₄ |
| Measurement Accuracy | ±(1–5 µg/m³ or 1–3% of reading, depending on parameter) |
| Detection Limits | 0.1–10 ppb (gases), 1 µg/m³ (PM) |
| Data Logging | 32 GB internal storage (>5 years at 1-min intervals) |
| Communication | Wi-Fi, Ethernet (LAN), optional 3G/4G cellular |
| Environmental Rating | IP65 |
| Operating Temperature | −35 °C to +50 °C |
| Power Supply | 90–264 VAC, 47–63 Hz (AQM65) |
| Dimensions | 1310 × 510 × 280 mm (AQM65), 483 × 330 × 187 mm (AQS1) |
| Weight | <30 kg (AQM65), <13 kg (AQS1) |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQS 1 |
| Particle Detection | PM₁, PM₂.₅, PM₁₀, TSP (via turbidimetric & optical counting) |
| Gaseous Pollutants | O₃, NO₂, CO, SO₂, NOₓ, H₂S, CO₂, VOC (ppb–ppm range), CH₄ |
| Detection Principle | Nephelometric turbidity (670 nm laser with sheath air), electrochemical (gases), and metal oxide semiconductor (VOC/CH₄) |
| Data Logging | Up to 32 GB internal storage (>5 years at 1-min intervals) |
| Environmental Rating | IP65 |
| Operating Temperature | −35 °C to +50 °C |
| Power Supply | 100–260 VAC (31.3 W typical) or 12 VDC (34.3 W, optional) |
| Dimensions | 483 × 330 × 187 mm (H×W×D) |
| Weight | <13 kg |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQS1 |
| Particle Measurement | PM1, PM2.5, PM10, TSP |
| Gas Measurement | O₃ (0–0.5 ppm), NO₂ (0–0.5 ppm), VOCs (0–0.5 ppm) |
| Meteorological Inputs | Temperature, Relative Humidity, Barometric Pressure, Wind Speed & Direction, Solar Radiation, Rainfall |
| Noise Measurement | 30–100 dB(A) |
| Sampling Method | Pump-aspirated with heated inlet (PM), dual-stage active flow control |
| Detection Limits | PM <1 µg/m³ |
| Accuracy | PM ±(2 µg/m³ + 5% of reading) |
| Operating Temperature | −10 °C to +45 °C |
| Enclosure | IP65 fiberglass housing with aluminum solar radiation shield |
| Power | 100–260 VAC (31.3 W) or 12 VDC (34.3 W) |
| Data Storage | 32 GB SSD (≥5 years at 1-min interval) |
| Connectivity | Wi-Fi, Ethernet, optional 4G HSPA cellular modem |
| Software | Aeroqual Connect (on-device web interface), Aeroqual Cloud (secure encrypted cloud platform) |
| Compliance | Designed for alignment with ISO 12103-1 (aerosol calibration), EN 14625 (O₃ monitoring), EN 14626 (NO₂ monitoring), and US EPA EQOA requirements for near-reference-grade performance |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | DusT Sentry |
| Particle Measurement Principle | Optical Particle Counting (OPC) via Right-Angle Laser Scattering |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, PM₁ |
| Optional Integrated Gases | VOCs, NO₂, O₃ |
| Sampling Flow Rate | 1.0 LPM |
| Detection Limit | <1 µg/m³ |
| Accuracy | ±(5 µg/m³ + 15% of reading) |
| Resolution | 0.1 µg/m³ |
| Data Logging Interval | 1 min to 24 h |
| Operating Temperature | −10 °C to +45 °C |
| Power Supply | 100–260 VAC (24.7 W) or 12 VDC (27.2 W) |
| Enclosure | IP65-rated GRP cabinet with aluminum solar radiation shield |
| Weight | <13 kg |
| Dimensions | 483 H × 330 W × 187 D mm (incl. shield & mounting hardware) |
| Data Storage | 32 GB SSD (≥5 years at 1-min intervals) |
| Certified | MCERTS-approved for precision and repeatability |
| Comms | Wi-Fi, Ethernet, optional HSPA 3G cellular modem |
| Software | Aeroqual Connect (browser-based local configuration), Aeroqual Cloud (secure encrypted remote data access, diagnostics, calibration logging, alarm management) |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | S300/S500 |
| Measurement Units | ppm, mg/m³, % RH, °C/°F |
| Display Functions | Current, Min/Max/Avg Values |
| Sampling | Active fan-assisted, interchangeable sensor heads |
| Calibration | Zero and span calibration supported |
| Temperature Range | −40 °C to 124 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Operating Temp. | 0–40 °C |
| Storage | −5 °C to 45 °C, 0–95% RH |
| Enclosure | PC/ABS, IP20 / NEMA 1 |
| Dimensions (w/sensor head) | 195 × 122 × 54 mm |
| Weight | <460 g (<16 oz) with battery & sensor |
| Power | Rechargeable 12 VDC Li-ion (2700 mAh) |
| Analog Output | 0–5 V |
| Digital Interface | RS-232 to USB |
| Data Logging Capacity | Up to 8,188 records |
| Clock | Real-time timestamping |
| Compliance | FCC Part 15 |
| EN 50082-1 | 1997 |
| EN 50081-1 | 1992 |
| Optional Accessories | Industrial protective housing, wall mount, IP41 remote sensor kit, carry case, humidity/temperature probe |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | Series 500 |
| Instrument Type | Portable |
| Detectable Gases | CO, CO₂, NO, H₂S, O₃ |
| Response Time | ≤120 s (T90, gas-dependent) |
| Measurement Accuracy | ±0.5–10% of reading + offset (gas- and sensor-specific) |
| Measurement Range | 0.001–10,000 ppm (gas-dependent) |
| Data Logging Capacity | 8,188 records (including 2,706 temperature/humidity entries) |
| Power | Rechargeable 12 V DC Li-ion battery (2.7 Ah), ~8 h operation |
| Dimensions (with sensor head) | 195 × 122 × 54 mm |
| Weight (with battery & sensor head) | <460 g |
| IP Rating | IP20 / NEMA 1 |
| Operating Environment | 5–45 °C, 0–95% RH (non-condensing) |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AEROQUAL Series 500 |
| Sensor Compatibility | Interchangeable modular sensor heads (sold separately) |
| Power | Rechargeable 12 V DC Li-ion battery (2700 mAh, ~8 h runtime) |
| Data Logging | 8,188 total readings (including up to 2,706 temperature/humidity records) |
| Communication | USB (RS-232 via adapter), 0–5 V analog output |
| Environmental Rating | IP20 / NEMA 1 |
| Dimensions | 195 × 122 × 54 mm (with sensor head) |
| Weight | <460 g (<16 oz) |
| Operating Range | 5–45 °C, 0–95 %RH (non-condensing) |
| Certifications | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | WS-APM02 |
| Particle Measurement Principle | Optical Particle Counter (OPC) with Right-Angle Laser Scattering |
| Measured Fractions | TSP, PM₁₀, PM₂.₅, PM₁ |
| Mass Concentration Range | PM₁: 0–200 µg/m³, PM₂.₅: 0–2000 µg/m³, PM₁₀: 0–5000 µg/m³, TSP: 0–5000 µg/m³ |
| Detection Limit | <1 µg/m³ |
| Accuracy | ±(5 µg/m³ + 15% of reading) |
| Sample Flow Rate | 1.0 L/min |
| Inlet Length | 36 cm with integrated heating element |
| Output Interfaces | RS-232 (legacy mode), 4× 4–20 mA analog outputs, 2× relay outputs |
| Averaging Intervals | 1 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 2 hr, 4 hr, 8 hr, 12 hr, 24 hr |
| Operating Temperature | −10°C to +50°C |
| Relative Humidity Range | 10–95% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Housing Material | Lockable GRP cabinet with integrated solar radiation shield |
| Dimensions (H×W×D) | 483 × 330 × 187 mm (including radiation shield and mounting bracket) |
| Weight | <13 kg |
| Meteorological Parameters | Wind speed & direction, air temperature, relative humidity, barometric pressure, precipitation, global solar radiation, photosynthetically active radiation (PAR) |
| Power Options | 100–260 V AC (15 W / 24 W) or 12 V DC (15 W / 24 W) |
| Data Storage | High-capacity internal memory |
| Communication | Optional wireless telemetry module (e.g., LTE/4G, LoRaWAN) |
| Compliance | Designed for continuous ambient air quality monitoring in accordance with ISO 12103-1 (test dust), EPA EQOA-PM-01 guidance, and EU Directive 2008/50/EC Annex III technical requirements for PM monitoring |