| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | CRTA-2 |
| Compliance | GB 9779–2015, GB 14907–2002, JG/T 157–2009 |
| Airflow Velocity | 3.0 ± 0.3 m/s |
| Test Specimen Dimensions | 150 × 70 × (4–6) mm |
| Timer Range | 0–99 h 99 min |
| Sample Substrate | Asbestos-free fiber-cement board (JC/T 412.1–2006, NAF HV grade, 4–6 mm thick) |
| Wet Film Thickness (Primer) | 80 µm |
| Drying Interval (Primer) | 1–2 h (tack-free) |
| Application Sequence | Primer → Immediate application of intermediate coat → Wind-induced drying test |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CTI-3 |
| Voltage Range | 100–600 V (25 V steps) |
| Electrode Material | Tungsten (99% purity) / Copper electrode holder |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Platinum Electrode Tip | 12 mm, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Drop Height | 35 ± 5 mm (adjustable) |
| Drop Interval | 30.00 ± 0.01 s (pre-settable) |
| Drops per cm³ | 44–55 |
| Total Drops Programmable | 1–9999 |
| Airflow Velocity | 0.2 m/s |
| Short-Circuit Current | 1.000 ± 0.001 A (voltage drop ≤ 8% at 1.0 A) |
| Tracking Threshold | 0.50 ± 0.05 A for ≥ 2.0 ± 0.2 s |
| Chamber Volume | > 0.5 m³ |
| Ambient Conditions | 0–40 °C, RH ≤ 80%, non-corrosive, vibration-free environment |
| Power Supply | 220 V AC, 0.6 kVA, 50–60 Hz |
| Dimensions (W×D×H) | 1160 × 600 × 1310 mm |
| Weight | Approx. 125 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DST-80kV |
| Breakdown Voltage Range | 0–80 kV AC (adjustable) |
| Voltage Accuracy | ±1% |
| Electrode Gap | 2.5 mm (calibrated with feeler gauge, tolerance ±0.1 mm) |
| Standard Electrodes | 12.5–13 mm diameter disc electrodes (brass or stainless steel, polished) |
| Test Cup Material | IEC 60156-compliant ceramic or borosilicate glass |
| Cup Capacity | ~500 mL |
| Rise Rate | 0.5–5.0 kV/s (programmable) |
| Trip Current Threshold | 5 mA |
| Power Consumption | ≤200 W |
| Safety Interlock | Door-activated high-voltage cutoff |
| Grounding Resistance Requirement | ≤4 Ω |
| Compliance | IEC 60156:2025, ASTM D1816, GB/T 507–2002, DL/T 846.7–2004 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | FTA-8 |
| Display | 7-inch full-color TFT touchscreen (800×480 resolution, RS232 interface, FPGA-driven, zero boot time) |
| Combustion Chamber Dimensions | 660 mm × 660 mm × 1065 mm (L×W×H) |
| Flame Height Adjustment Range | 150–180 mm |
| Fuel Consumption Rate | 2.55 ± 0.15 mL/min |
| Flame Temperature Verification | 960 ± 60 °C at 50 mm from burner orifice (validated via 0.71 mm bare copper wire melt test within 6 s) |
| Timing Accuracy | ±0.1 s for both ignition and afterflame/afterglow duration |
| Repeatability Error | ±0.1 s |
| Fuel Composition | 5% (v/v) methanol + 95% (v/v) ethanol (user-prepared) |
| Construction | Electrostatically painted steel enclosure |
| Data Management | Internal storage (1 GB), historical test recall, automatic timing for ignition, flame-on, and afterflame/afterglow phases |
| Compliance Standards | MT 914–2008, GB 16413–2009, MT 113–1995 |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Ventilation Requirement | Mandatory fume hood or integrated exhaust & purification system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTA-8 |
| Price Range | USD 3,500 – 7,000 |
| Application Field | Fire-Retardant Coatings |
| Test Objects | Plastics, Woven & Nonwoven Textiles |
| Repeatability Error | ±0.1 s |
| Compliance Standard | GB 14645–2014 (Equivalent to ISO 14054 for 45° flammability testing) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GB/T 1692 Resistivity Tester |
| Compliance | GB/T 1692–2008, GB/T 1410, ASTM D257, IEC 60093 |
| Measurement Range | 1 × 10⁶ Ω to 1 × 10¹⁶ Ω |
| Test Voltages | 100 V, 250 V, 500 V, 1000 V (DC) |
| Electrode Configuration | Three-electrode system (main electrode Ø50 mm, guard ring ≥10 mm wide, grounded outer electrode) |
| Accuracy | ±20% of reading |
| Environmental Control Support | Compatible with standard climatic chambers (23 ± 2 °C / 50 ± 5 %RH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GBFS-1 |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Power Consumption | 180 W |
| Temperature Range | 800 ±30 °C (max 900 °C, Class 1 accuracy) |
| Temperature Stabilization Time | <3 min |
| Flame Source | Dual LPG burners (inner diameter Φ9.5 ±0.5 mm, length ~100 mm |
| Gas Flow Control | 100–1000 mL/min |
| Load Application | 7, 10, 12, 15, 17, or 20 N (equivalent to 0.75–2.04 kgf) |
| Specimen Dimensions | 300 mm × 50 mm, with two 25-mm-offset suspension holes |
| Test Duration Resolution | 0.1 s |
| Repeatability Error | ±0.1 min |
| Ignition | Automatic electronic ignition |
| Temperature Monitoring | Dual thermocouples positioned 5 mm from specimen surface |
| Data Display | Digital real-time readout of temperature and elapsed time |
| Compliance Standard | GB/T 9775–2008 (identical to ISO 6308:1980) |
| Enclosure Dimensions | 700 × 300 × 600 mm (W×D×H) |
| Weight | ~30 kg |
| Ventilation Requirement | Mandatory fume extraction via ducted hood or integrated smoke treatment system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GWA-10 |
| Price Range | USD 3,500 – 7,200 |
| Application Fields | Wire & Cable |
| Test Objects | Electrical Insulation Materials, Engineering Plastics |
| Repeatability Error | ±0.1 s |
| Primary Function | Glow-Wire Ignitability Testing (GWIT/GWFI) |
| Glow-Wire Temperature Range | 500–1050 °C ±2 °C |
| Glow-Wire Duration | 0–999.9 s ±0.1 s |
| Ignition Time & Extinction Time Measurement | 0–999.9 s ±0.1 s (auto-recorded, manual pause enabled) |
| Glow-Wire Specification | Ø4 mm Ni80/Cr20 alloy wire |
| Applied Force | 0.95 ±0.1 N |
| Penetration Depth | 7 ±0.5 mm |
| Linear Actuation Speed | 14 mm/s |
| Thermocouple | Ø1 mm imported K-type armored thermocouple |
| Test Chamber Volume | ≥0.5 m³ (standard) |
| Background Illuminance | ≤20 lux (black background) |
| Power Supply | 220 V ±10%, 50 Hz, 500 W |
| Net Weight | ~100 kg |
| Footprint | 1160 mm (W) × 600 mm (D) × 1310 mm (H) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | HDT-VST-300E |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Heating Medium | Methyl Silicone Oil (up to 300 °C) or Transformer Oil (up to 200 °C) |
| Standard Config | 3 Test Stations |
| Load Application | Mechanical Deadweight via Precision Calibration Weights |
| Temperature Sensing | PT100 Platinum Resistance Thermometer |
| Deformation Sensing | High-Resolution Digital Micrometer Sensor (0–10 mm range, 0.001 mm resolution) |
| Control System | 32-bit ARM Embedded Processor with Real-Time Isothermal Ramp Algorithm |
| Compliance | ISO 75-1:1993, ISO 306:1994, GB/T 1633–2000, GB/T 1634–2001 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | LDQ-5 |
| Voltage Range | 50–600 V AC/DC (±1% step accuracy) |
| Electrolyte | NH₄Cl solution (0.1–1.0 wt%), flow rate 0.5–2.0 mL/min (programmable) |
| Electrode Material | Pt-Rh alloy |
| Electrode Angle | 60° ± 5° |
| Electrode Force | 1.0 N ± 0.05 N |
| Trip Current Threshold | 0.5 A ± 10%, arc duration ≥ 2 s |
| Temperature Sensor Accuracy | ±1 °C |
| Humidity Range | 20–80 %RH |
| Data Acquisition | 16-bit resolution, current resolution 0.1 mA |
| Compliance | IEC 60112:2020, ASTM D3638-21, UL 746A, GB/T 4207-2022, VDE 0303-11, IEC 60695-2-2 |
| Key | Brand: Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | OI-2 |
| Measurement Range | 0–100% O₂ |
| Accuracy | ±2.5% O₂ |
| Response Time | <10 s |
| Output Drift | <5% per year |
| Sample Form | Solid only |
| Operating Pressure | 0.1–0.15 MPa |
| Gas Flow Rate | 10.0 ± 0.5 L/min |
| Compliant With | GB/T 2406 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSJF-2 |
| Application Field | Electrical Wires and Cables |
| Test Object | Bundled Wire and Cable Assemblies |
| Primary Function | Fire Performance Evaluation per GB/T 31248–2014 and GB/T 18380.31–2008 (IEC 60332-3-10:2000 IDT) |
| Structural Dimensions (Overall Installation Space) | 2500 mm (W) × 4500 mm (D) × 5500 mm (H) |
| Net Weight | ~2500 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 7 kW |
| Cooling Water Requirement | Continuous supply with dedicated drainage |
| Fuel Source | Industrial propane with regulated flow (≥300 L/min compressed air via 3 kW air compressor) |
| Exhaust Handling | Integrated smoke collection and wet-scrubbing system compliant with local emission regulations |
| Safety Infrastructure | Requires 5-ton forklift, overhead crane, and three 5-m-height scaffolds for installation |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | SDC-2 |
| Chamber Volume | 27 m³ (3 m × 3 m × 3 m) |
| Light Source | 12 V, 100 W quartz-halogen lamp (400–750 nm) |
| Photodetector | Silicon photodiode |
| Transmittance Range | 0.0001–100% |
| Accuracy | ±3% |
| Power Supply | 220–240 V AC, 50 Hz, 4 kW |
| Operating Ambient | 15–40 °C, RH ≤85%, no direct sunlight or forced airflow |
| Compliance | GB/T 17651.1–2, IEC 61034-1–2 |
| Ignition System | Integrated automatic alcohol-based ignition |
| Software | Proprietary Windows-based transmittance acquisition and reporting suite with real-time curve plotting and GLP-compliant data export |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | TCA-3030 |
| Measurement Principle | Guarded Hot Plate Method (ASTM C177 / ISO 8302 / GB/T 10294-2008) |
| Thermal Conductivity Range | 0.01–1 W/(m·K) |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Temperature Range (Cold Plate) | 5–90 °C |
| Max. Hot Plate Temperature | 120 °C |
| Sample Dimensions | 300 mm × 300 mm, Thickness ≤37.5 mm |
| Sample Form | Solid, Homogeneous Flat Panels |
| Test Environment | Ambient (Controlled Room: 8–35 °C, RH <80%) |
| Power Supply | 3 kW, 220 V AC |
| Overall Dimensions (L×W×H) | 1120 × 830 × 1600 mm |
| Automation | Microprocessor-Controlled with Real-Time Data Acquisition & Reporting |
| Compliance | Fully aligned with GB/T 10294-2008, ASTM C177, ISO 8302, and EN 12664 for steady-state thermal resistance measurement |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | TFR-1 |
| Dimensions (W×D×H) | 1160 mm × 600 mm × 1310 mm (including feet) |
| Sample Holder | Anthropomorphic Metallic Headform (1:1 scale) |
| Flame Temperature Range | 750–950 °C |
| Headform Travel Speed | (60 ± 5) mm/s |
| Afterflame Timing Resolution | 0.1 s |
| Power Supply | 220 V, 50 Hz, 150 W |
| Fuel Compatibility | Propane, Liquefied Petroleum Gas (LPG), or ≥98% Methane |
| Compliance Standards | GB 2626, GB 19082, GB 19083, GB/T 32610, YY 0469, YY/T 0969 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | TR-200A |
| Instrument Type | Torque Rheometer |
| Sample State | Solid (powder, granules, pellets) |
| Sample Viscosity Range | Low-to-Medium Melt Viscosity |
| Motor & Drive | Panasonic AC Servo Motor with Integrated Controller |
| Temperature Range | Ambient to 350 °C (5-zone independent control) |
| Speed Range | 0.1–2000 rpm |
| Max Torque | 300 N·mm (0–200 N·m full-scale measurement range) |
| Torque Resolution | ±0.3% FS |
| Speed Control Accuracy | ±0.2% FS |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Measurement Range (optional) | 0.1–100 MPa |
| Pressure Accuracy | ±0.3% FS |
| Data Acquisition Rate | 50 Hz |
| Power Supply | AC 380 V, 7.5 kW |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | VFT-3 |
| Applicable Standard | GB/T 18380.11–2022, GB/T 18380.12–2022, IEC 60332-1/2 |
| Flame Power | 1 kW |
| Flame Angle | 45° |
| Timing Resolution | ±0.1 s (0–999.9 s) |
| Repeatability Error | ±0.1 s |
| Gas Supply | 95% propane (LPG-compatible) |
| Power Supply | AC 220 V / 50 Hz |
| Enclosure Material | Electrostatically Painted Steel Plate |
| Dimensions (W×D×H) | 720 × 580 × 1680 mm |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VFTA-2 |
| Price Range | USD 3,600 – 7,200 |
| Dimensions (W×D×H) | 1160 × 600 × 1250 mm |
| Combustion Chamber Volume | >0.5 m³ |
| Background | Matte Black, Illuminance ≤20 lux |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 150 W |
| Fuel Gas | Industrial propane, butane, or propane-butane mixture |
| Ignition Timer Range | 0–999.9 s |
| Burn Time Measurement Range | 0–999.9 s |
| Timing Resolution | 0.1 s |
| Flame Positioner Distances | 17 ±1 mm and 20 ±1 mm |
| Flame Height Calibration | 40 ±2 mm (vertical), 25 ±2 mm (horizontal) |
| Combustion Chamber Internal Dimensions | 900 × 600 × 1000 mm |
| Approx. Weight | 80 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | WCF-1 |
| Dimensions (L×W×H) | 700 × 400 × 720 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 100 W |
| Gas Source | Natural gas or LPG |
| Ignition Temperature Control | 310 °C ±10 °C |
| Timing Accuracy | ±0.1 s (within 3 min) |
| Repeatability Error | ±0.1% (mass loss) |
| Sample Form | Solid wood specimens |
| Specimen Dimensions | 76 × 13 × 13 mm (±1 mm) |
| Conditioning | 23 ±2 °C, 50 ±5% RH until mass change <1% over 24 h |
| Compliance | GA/T 42.1–2003 “Test Method for Combustion Performance of Flame-Retardant Wood — Pile-Burning Method” |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZDH-20kV |
| Breakdown Voltage | 20 kV |
| Compliance Standards | IEC 61621, ASTM D495, GB/T 1411 |
| Electrode Spacing | 4 mm or 6.35 mm (adjustable) |
| Arc Current Range | 10–40 mA |
| Output Voltage | AC/DC, 0–20 kV |
| Safety Features | Interlocked arc chamber, emergency stop, grounding resistance ≤2 Ω |
| Calibration Interval | Semi-annual (±2% voltage accuracy) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZFA-1 |
| Price Range | USD 18,000 – 22,500 |
| Power Supply | AC 220 V, 50 Hz, ~0.5 kW |
| Exhaust Air Velocity | (2.5 ± 0.2) m/s |
| Fire-Resistant Porous Board Dimensions | (300 ± 10) mm × (450 ± 10) mm,耐900°C+ |
| Radiant Thermometer Range | 480–530 °C |
| Radiant Thermometer Accuracy | ±0.5% of reading |
| Thermocouple | 3.2 mm stainless steel sheathed type K |
| Heat Flux Meter Range | 0–15 kW/m² |
| Heat Flux Meter Accuracy | ±3% full scale |
| Heat Flux Meter Precision | ±0.2 kW/m² |
| Anemometer Accuracy | ±0.1 m/s |
| Timer Accuracy | <1 s/h |
| Overall Dimensions (L×W×H) | 2400 mm × 1340 mm × 3100 mm (incl. duct bend) |
| Specimen Size | (1050 ± 5) mm × (230 ± 5) mm (6 specimens per test series) |
| Conditioning Standard | EN 13238 |
| Igniter Gas Flow | (1.56 ± 0.12) L/min |
| Igniter Flame Height | 60–120 mm |
| Ignition Duration | 10 min at (10 ± 0.2) mm upstream of specimen zero point |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZFA-1 |
| Price Range | USD 17,200 – 20,700 |
| Power Supply | AC 220 V, 50 Hz, ~0.5 kW |
| Exhaust Air Velocity | (2.5 ± 0.2) m/s |
| Fire-Resistant Porous Board Dimensions | (300 ± 10) mm × (450 ± 10) mm,耐900°C+ |
| Radiant Panel Blackbody Temperature Range | 480–530 °C |
| Radiant Panel Temperature Accuracy | ±0.5% of reading |
| Thermocouple | 3.2 mm stainless steel sheathed K-type |
| Heat Flux Meter Range | 0–15 kW/m² |
| Heat Flux Meter Accuracy | ±3%, ±0.2 kW/m² |
| Anemometer Accuracy | ±0.1 m/s |
| Timer Accuracy | <1 s/h |
| Overall Dimensions (L×W×H) | 2400 mm × 1340 mm × 3100 mm (incl. duct bend) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZH-50KV |
| Breakdown Voltage Range | 0–50 kV (AC/DC/Impulse) |
| Output Capacity | ≥10 kVA (compliant with GB/T 1408.1) |
| Voltage Accuracy | ≤1.5% FS (standard), optional ≤0.5% FS |
| Ramp Rate | 0.1–5 kV/s (adjustable), optional 0.01–10 kV/s (stepless) |
| Breakdown Detection Sensitivity | 0.1 mA (standard), optional 0.01 mA |
| Data Storage | 100 test records (standard), optional 1000+ with cloud backup |
| Safety Compliance | Triple Interlock Protection (door interlock, overcurrent cutoff ≤0.1 s, emergency stop), grounding resistance ≤4 Ω, discharge rod included |
| Environmental Options | Ambient (15–40 °C, RH ≤70%), optional high-temp chamber (RT to 200 °C, ±1 °C), optional low-temp chamber (−70 °C), oil-immersion testing (25# transformer oil, oil bath available) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV AC/DC |
| Voltage Accuracy | ≤ ±1% |
| Ramp Rate | 0.01–5.0 kV/s (adjustable) |
| Current Detection Threshold | 1–30 mA (configurable) |
| Trip Response Time | ≤ 0.1 s |
| Data Sampling Rate | 500 Hz |
| Test Media | Air, Insulating Oil |
| Standard Electrode Diameters | 6 mm, 25 mm, 75 mm |
| Power Rating | Up to 10 kVA |
| Hold Time Range | 0–8 h |
| Compliance | IEC 60243-1, IEC 60243-2, GB/T 1408.1, GB/T 1408.2, ASTM D149, ASTM D877 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJC-100KV |
| Price Range | USD 7,000 – 21,000 (FOB) |
| Maximum Output Voltage | 100 kV |
| Voltage Ramp Rate | 0.5–5 kV/s (continuously adjustable) |
| Voltage Measurement Range | 0–100 kV |
| Voltage Resolution | 1 V (10-bit A/D) |
| Breakdown Current Range | 0.1–100 mA |
| Current Accuracy | ±1% FS |
| Overvoltage Protection Threshold Accuracy | ±5% |
| Overcurrent Response Time | <1 ms |
| Flashover Auto-Restart Delay | 0–60 s (adjustable) |
| Safety Interlock Compliance | IEC 61010-1 |
| Data Sampling Rate | 500 Hz |
| Output Formats | CSV (raw), PDF (standard report) |
| Environmental Operating Conditions | 25±5°C, ≤65% RH |
| Electrode Material | Tungsten-Copper |
| Recommended Electrode Maintenance | Polishing with #800 grit sandpaper after every 50 tests |
| Transformer Oil Service Interval | Filtration required after 500 operating hours |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Max Output Voltage | 100 kV (AC/DC) |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Power Rating | 5 kVA |
| Voltage Regulation | Continuous, stepless (0–3000 V/s) |
| Voltage Measurement Accuracy | ≤ ±1% |
| Test Environments | Air or Transformer Oil Immersion |
| Safety Response Time | ≤ 0.01 s for overcurrent cutoff |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 0–85% RH (non-condensing) |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, GB 12656, ASTM D149, ASTM D876, DIN 53481, IEC 60243, UNI 4291 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Max Output Voltage | 100 kV AC/DC |
| Voltage Measurement Range | 0–100 kV (AC/DC) |
| Voltage Accuracy | ±1.5% (10–100% of full scale) |
| Rise Rate Adjustment | 0.1–3 kV/s (continuously variable, no gear shifting) |
| Test Modes | Ramp-up, Step-up, and Hold (with programmable dwell time up to 4 h, extendable per DIN/VDE/IEC conventions) |
| Power Rating | 10 kVA |
| Overcurrent Protection | 1–30 mA (software-configurable) |
| Safety Features | Nine-level interlock system including overvoltage cutoff, door interlock, automatic discharge post-test, zero-voltage reset, independent grounding, short-circuit detection, and software operation validation |
| Dimensions (L×W×H) | 2100 × 1500 × 2100 mm |
| Net Weight | 1800 kg |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149, GB/T 3333, GB/T 12656, HG/T 3330 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Test Voltage | 100 kV AC/DC |
| Voltage Accuracy | ≤2% |
| Rise Rate Range | 0.01–5 kV/s (adjustable in real time) |
| Test Modes | AC/DC, stepwise ramp, withstand, breakdown |
| Electrode Options | 6 mm sphere, 25 mm & 75 mm flat disc electrodes |
| Test Medium | air or insulating oil |
| Safety Protection | 9-level interlocked protection system |
| Power Rating | 10 kVA |
| Compliance | GB/T 1408.1–2016, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149–2023 |
| Software | PC-based control with real-time curve plotting, automatic breakdown detection, data logging, audit trail, and multi-sample parallel testing capability |
| Dimensions (L×W×H) | 1900 × 1300 × 1700 mm |
| Weight | 200 kg |
| Warranty | 3 years comprehensive, lifetime technical support |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV |
| Compliance | GB/T 1408.1–2016, IEC 60243-1, ASTM D149 |
| Test Modes | Short-time, Stepwise (20 s/60 s), Ramp (120–600 s), Proof Testing |
| Electrode Configurations | Coaxial cylindrical, spherical, parallel plate, rod-to-rod, foil-wrapped tubular, and custom fixtures per ISO/IEC standards |
| Voltage Regulation Accuracy | ≤ ±2% of set value |
| Rise Time Control | Adjustable from 1 V/s to 5000 V/s |
| Measurement Uncertainty | ≤ ±3% (kV), traceable to national metrology standards |
| Safety Interlocks | Dual-channel overcurrent cutoff (<5 ms response), ground-fault detection, door-activated HV disable, arc-quenching chamber |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Output Voltage | AC/DC 0–100 kV |
| Output Power | 5 kVA |
| Voltage Measurement Accuracy | ≤ ±2% |
| Ramp Rate | 0.1–10 kV/s |
| Withstand Test Voltage Range | 10–100 kV (continuously adjustable) |
| Withstand Duration | 0–4 h (no-current condition) |
| Input | 220 V ±10%, 50 Hz ±1% |
| Dimensions (L×W×H) | 700 × 800 × 1650 mm |
| Weight | 100 kg |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 30–85% RH |
| Grounding Resistance Requirement | ≤ 4 Ω |
| Short-Circuit & Overcurrent Protection Response Time | ≤ 0.1 s |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149 |