Agela
Filter
Showing 1–30 of 61 results
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AcceleSep Petroleum Fraction Rapid Separation System |
| Pricing | Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ASTRA |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| UV-Vis Detection | PDA Detector, 200–800 nm |
| Gradient Capability | Quaternary Solvent Selection |
| Column Compatibility | Normal- & Reversed-Phase Columns (4–800 g), Max. Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-051 |
| Instrument Type | Preparative HPLC/LC Autosampler |
| Maximum Sample Capacity | 5 vials |
| Minimum Sample Volume per Injection | 1 mL |
| Loop Volume Range | 2–20 mL |
| Positioning Accuracy | ±0.1 mm (verified by encoder feedback) |
| Drive Mechanism | Precision Syringe Pump |
| Needle Wash | Integrated Solvent Flush with Dual-Path Solvent Selection |
| Repeat Injection Capability | Unlimited cycles per sample |
| Maximum Single Injection Volume | 50 mL |
| Compatibility | Standalone operation or integration with third-party preparative LC systems (e.g., Gilson, Biotage, Teledyne ISCO, Shimadzu, Waters) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-A5 |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 108 × 2 mL vials (standard), optional configurations available |
| Injection Modes | Full-loop, Partial-loop, and Needle-in-Loop (NIL) injection |
| Injection Volume Range | 0.1–25 µL (with standard loop) |
| Precision | RSD < 0.25% (full-loop), < 0.5% (partial-loop, >10 µL), < 0.8% (NIL, <5 µL) |
| Carryover | < 0.05% |
| Maximum System Pressure | 40 MPa (standard HPLC), 60 MPa (UHPLC-compatible) |
| Safety Features | Vial-missing detection, needle-strike alarm, tubing blockage detection, leak monitoring |
| Optional | Peltier-based sample cooling module |
| Dimensions (W×D×H) | 300 × 450 × 320 mm |
| Weight | ~25 kg |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AZOFF |
| Price Range | USD 14,000–35,000 |
| Automation Level | Fully Automated |
| Number of Channels | Up to 24 parallel positions (expandable via modular configuration) |
| Extraction Format | Column-based SPE |
| Flow Rate Control | 1–60 mL/min (precisely regulated via syringe pump) |
| Eluent Solvent Capacity | Single solvent reservoir (compatible with ethyl ether, dichloromethane, and other low-boiling-point organic solvents) |
| Sample Capacity | 8–24 samples per run |
| Sample Loading Volume | Up to 20 mL per column |
| Wetted Materials | PTFE only (including tubing, valves, and fluidic pathways) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BioGantry |
| Pricing | Available Upon Request |
| Liquid Handling Range | 10–1000 µL |
| Motion Control | Computer-Controlled X/Y/Z Axes |
| Plate Compatibility | Standard 96-Well Plates, Multi-Tube Racks (Customizable) |
| Software | Bilingual (English/Chinese), Method & Report Archiving, Audit-Trail Enabled |
| Compliance | GLP-Compliant Workflow Logging, Traceable Liquid Handling Events |
| Connectivity | Surface-Based Wireless Operation |
| Enclosure | Fully Sealed System Architecture |
| Brand | Agela |
|---|---|
| Model | CC-100 |
| Origin | Tianjin, China |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability | ±0.1°C |
| Temperature Uniformity | ±0.3°C (across chamber) |
| Control Method | PID digital control with touch keypad |
| Display | LED digital display |
| Safety Features | Over-temperature protection cutoff |
| Chamber Design | Vertical upright configuration with magnetic-latch dual-layer lid (outer magnetic cover + insulated inner cover) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 320 × 380 mm |
| Net Weight | 8.5 kg |
| Cooling | None (heating-only operation) |
| Brand | Agela |
|---|---|
| Model | CHEETAH HP100 / Agela cMS |
| Instrument Type | Single Quadrupole LC-MS |
| Mass Range | m/z 10–1200 |
| Sensitivity | S/N ≥ 100:1 (100 pg reserpine, full scan |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Mass Stability | ±0.1 Da |
| ESI Ion Source | Standard |
| Polarity | Positive/Negative Switchable |
| Scan Speed | 5000 Da/sec (UPLC-compatible) |
| Flow Rate Compatibility | 10–100 µL/min |
| HPLC/Purification Pump Flow Range | 0.1–100 mL/min |
| Max Pressure | 20 MPa |
| UV Detection | 200–400 nm (D₂ lamp), optional 200–800 nm (D₂ + W lamp) |
| Wavelength Accuracy | ±1 nm |
| Bandwidth | 8 nm |
| Flow Precision | ±1% |
| Flow RSD | ≤0.3% |
| Pressure Pulsation | ≤0.3 MPa |
| Fraction Collector | 2D robotic, customizable coordinates, tube sizes: 13/15/18/25 mm |
| Operating System | Windows XP (industrial-grade PC) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH II |
| Instrument Type | Fast Liquid Chromatography (Flash) |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| Sample Injection Positions | 1–100 |
| Injection Volume Ratio | 1–10% |
| Temperature Control | 25°C (ambient, non-thermostatted) |
| Wavelength Range | 200–800 nm |
| Data Acquisition Frequency | Not specified (system supports real-time UV/VIS spectral scanning) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH MP200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative HPLC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (standard detector), 200–800 nm (optional dual-range detector) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | ≤3×10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Configuration | Binary or Quaternary |
| Detection Modes | Single-Wavelength, Dual-Wavelength (independent collection & monitoring), Ratio-Based Triggering |
| Fraction Collection | Integrated 2D Fraction Collector with Adjustable Rack Mapping |
| Solvent Compatibility | All Common HPLC-Grade Organic and Aqueous Solvents |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection with Audible/Visual Alert |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CH-200P |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CH-200P |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Rate Range | 1–200 mL/min |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Flash columns (4–800 g silica/C18), max. sample load: 80 g |
| Collection Modes | Full collection, peak-based collection, manual collection, time-window collection |
| Real-time Fraction Mapping | Color-coded tube assignment per detected peak |
| Purge Function | Integrated air pump module for manual/automated column purging |
| Interface | Touchscreen GUI with transparent fluidic pathway visualization |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH Pro CH-200PII |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Normal- and Reversed-Phase Flash Columns (4–800 g), Max Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Real-Time Tube Mapping | Color-Coded Fraction Tube Assignment per Peak |
| Optional Air-Purge Module | Integrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | CH-200PII |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Normal-Phase & Reversed-Phase Flash Columns (4–800 g), Max. Sample Load: 80 g |
| Collection Modes | Full Collection, Peak-Based Collection, Manual Collection, Time-Window Collection |
| Real-Time Fraction Mapping | Color-Coded Tube Assignment per Detected Peak |
| Optional Air-Purge Module | Integrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MP200 |
| Price Range | USD 14,000–28,000 |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ≤2% |
| Maximum Operating Pressure | 200 psi |
| Detection Wavelength Range | Not Specified |
| Wavelength Reproducibility | Not Specified |
| Baseline Noise | Not Specified |
| Data Acquisition Frequency | Not Specified |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | SPE-M96 |
| Automation Level | Semi-Automatic |
| Channel Configuration | 96-Channel Parallel |
| SPE Format | Column-Based (96-Well Plate Compatible) |
| Pressure Delivery | Positive Pressure (Up to 60 psi) |
| Flow Control | Manual Regulator |
| Solvent Selection | Manual Solvent Switching |
| Sample Capacity | Up to 96 Samples per Run |
| Sample Loading | Manual |
| Wetted Materials | PTFE (Polytetrafluoroethylene) |
| Gas Source Required | Compressed Air or Nitrogen |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Cleanert V96 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Uniformity | ±1°C |
| Sample Format | 96-well microplate |
| Gas Flow Rate | 0–80 L/min |
| Heating Power | 450 W |
| Sample Capacity | 96 positions |
| Gas Heating Uniformity | Optimized for consistent thermal delivery across all wells |
| Adjustable Gas Manifold Height | Yes |
| Removable Gas Manifold | Yes |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Cleanert V96 |
| Heating Method | Dry-block heating |
| Temperature Control Range | 10°C to 30°C ambient operating environment |
| Temperature Setting Range | Room temperature +5°C to 80°C |
| Temperature Stability | ±0.5°C (typical at setpoint) |
| Gas Flow Rate | 10–100 L/min (adjustable per channel) |
| Sample Capacity | Configurable for 24-, 48-, or 96-well formats via modular gas manifolds |
| Dimensions (W×D×H) | 360 mm × 287 mm × 367 mm |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | EOPC® Automated Polar Compound Separation System |
| Detection Principle | Normal-phase liquid chromatography with UV detection (200 nm) |
| Column Format | Standardized disposable EOPC separation cartridges (pre-packed silica-based) |
| Automation Level | Fully automated sample injection, gradient elution, fraction collection, and real-time UV monitoring |
| Throughput | Up to 6 samples unattended |
| Compliance | Designed to meet requirements of GB 5009.202–2016 “Determination of Polar Compounds in Edible Oils” |
| Solvent Management | Dual 4 L solvent reservoirs with dry-ice–assisted cooling (4 °C to ambient) |
| Flow Control | Valveless precision metering pump (±0.5% flow accuracy, 25 mL/min max) |
| Fraction Collection | Programmable S-type collector with coordinate customization, multi-channel waste/collect switching, compatibility with conical flasks, round-bottom flasks, and beakers |
| UV Detector | Fixed-wavelength 200 nm detector with real-time chromatogram display |
| Display | Integrated LED touchscreen showing pressure, flow rate, gradient profile, and run progress |
| Safety Design | Fully enclosed fluidic path |
| Software | Embedded method library including GB 5009.202–2016-compliant SOPs |
| audit-trail–capable operation log (GLP-supporting metadata | user ID, timestamp, method version, instrument parameters) |
| Brand | Agela |
|---|---|
| Model | FL-C100 |
| Type | Mixed-Mode Fraction Collector |
| Collection Axes | X-Y Dual-Axis |
| Positioning Accuracy | ≤ ±0.5 mm |
| Compatible Vessel Types | Conical Flasks, Round-Bottom Flasks, Beakers, Test Tubes |
| Waste/Collection Channel Switching | Dual-Path Solenoid-Valve Controlled |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 420 × 480 × 450 mm |
| Weight | 28 kg |
| Origin | Tianjin, China |
| Regulatory Compliance | CE-marked per EN 61010-1 for Laboratory Equipment |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Type | Liquid-phase Fraction Collector |
| Max Flow Rate | 1 L/min |
| Collection Vessel Options | 13 mm, 15 mm, 18 mm, 25 mm test tubes & 100 mL conical flasks |
| Collection Modes | Full-collection, Manual-triggered, Threshold-triggered (peak-based), Waste/Collection Switching |
| Tube Rack Compatibility | F1–F4 standard racks (13–25 mm) + custom rack support |
| Interface | RS-232 |
| Design | Multi-channel bow-shaped collection head with adjustable software-defined coordinates |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FL-MH100 |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FLEXA HP 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 20–30 MPa |
| Wavelength Range (UV-Vis Detector) | 190–800 nm |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise (UV-Vis, 254 nm, 1 s) | < ±2.5 × 10⁻⁵ AU |
| Data Acquisition Rate | Up to 20 Hz |
| Detector Options | UV-Vis, ELSD, RI |
| Fraction Collection Modes | Time-based, Peak-triggered, Threshold-based, User-defined Coordinates |
| Communication Interface | RS-232, Optional Ethernet/USB |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H100G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | ±1 % |
| Maximum Operating Pressure | 20 MPa |
| Brand | Agela |
|---|---|
| Model | FL-H1000G |
| Origin | Tianjin, China |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0–1000 mL/min |
| Flow Accuracy | ±3% |
| Maximum Operating Pressure | 10 MPa |
| Application Level | Laboratory-Scale Purification |
| Configuration | Modular (Pump, UV/Vis Detector, Fraction Collector, Auto-Sampler, Column Switching Valve) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H300G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–300 mL/min |
| Flow Accuracy | ±2% |
| Maximum Operating Pressure | 15 MPa |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H050G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.1–50 mL/min |
| Flow Accuracy | ±1% RSD |
| Maximum Operating Pressure | 30 MPa |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | FLEXA |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–100 mL/min (FLEXA GP100), 1–200 mL/min (FLEXA GP200), 1–30 L/min (FLEXA GP030) |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (FL-UV2040), 200–800 nm (FL-UV2080/2080B) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise | ≤3 × 10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Composition Accuracy | ±1% |
| Gradient Modes | Binary, Linear, Isocratic, and Custom Profiles |
| Detector Channels | Dual-Wavelength Simultaneous Detection |
| UV Source | Deuterium Lamp (200–400 nm), Tungsten Lamp (400–800 nm) |
| Collection Vessels | 13 mm, 15 mm, 18 mm, 25 mm test tubes, and 100 mL Erlenmeyer flasks |
| Fraction Trigger Modes | Full Collection, Manual Trigger, Threshold-Based Peak Detection |
| Communication Interface | RS-232 |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | FLEXA-MH |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 200–800 nm (selectable dual-wavelength mode) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | Not specified |
| Detection Options | UV-Vis (dual-wavelength), optional ELSD or RI detector |
| Gradient Capability | Binary gradient, supporting linear, isocratic, and custom profiles |
| Column Configuration | Compatible with both reversed-phase and normal-phase chromatography |
| Collection Mode | X/Y-axis programmable fraction collector |