Agela
Filter
Showing 31–60 of 61 results
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-D-5800P |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV Detection Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-D-5800P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HS-D-5800P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Model | LC-10F |
| Origin | Tianjin, China |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Max Operating Pressure | ≤ 42 MPa (316L stainless steel pump head) |
| Injection Capacity | Not specified |
| Column Oven Temperature Control | Not specified |
| UV-Vis Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU (254 nm, time constant = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Flow Accuracy | ±0.5 % (at 1 mL/min, 10 MPa) |
| Flow Precision | RSD ≤ 0.1 % (at 1 mL/min, 10 MPa) |
| Pressure Pulsation | ≤ 0.5 % (at 1 mL/min, 10 MPa) |
| Detector Light Sources | Deuterium lamp (standard), Tungsten lamp (optional) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic HPLC System |
| Model | LC-10F |
| Instrument Type | Conventional Analytical HPLC |
| Flow Rate Range | 1–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Injection Volume Range | 1–20 µL |
| Wavelength Range | 200–800 nm |
| Data Acquisition Rate | Up to 60 Hz (programmable) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | LC2000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | ≤70 MPa |
| Flow Accuracy | ±1% |
| Injection Volume Range | 0–100 µL (standard) |
| Sample Capacity | Vial tray & 96-well plate compatibility |
| Column Oven Temperature Range | 4–90 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Flow Precision (RSD) | ≤0.075% |
| Pressure Pulsation | ≤0.2 MPa or ≤1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise (UVD) | ±5 µAU |
| Baseline Drift (UVD) | 1×10⁻⁴ AU/h |
| Flow Cell Volume | 2.5 µL (5 mm path) / 13 µL (10 mm path) |
| Injection Carryover | <0.002% |
| Temperature Stability | ±0.1 °C |
| Column Compatibility | up to 300 mm length |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Multi-Stage Chromatographic Purification System |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System |
| Configuration | Integrated Three-Stage Automated Purification Platform |
| Application Focus | Downstream Processing of Biologics, Natural Product Isolation, and Complex Matrix Sample Purification |
| Compliance Framework | Designed to support GLP-compliant workflows and scalable process development |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | NV-15G |
| Heating Method | Dry-block heating |
| Temperature Range | ≥5 °C above ambient to 150 °C |
| Temperature Uniformity | ±0.3 °C |
| Sample Capacity | 15 positions |
| Well Diameter | 19 mm |
| Well Depth | 70 mm |
| Gas Flow Rate | 0–15 L/min (0–100 psi) |
| Power Supply | 220 V / 50 Hz |
| Max. Power | 240 W |
| Net Weight | 4.7 kg |
| Operating Environment | 0–50 °C, ≤85% RH |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | NV15-G |
| Heating Method | Water Bath |
| Temperature Range | >5 °C above ambient to 80 °C |
| Temperature Stability | ±1 °C |
| Sample Tube Diameter | 20 mm |
| Gas Flow Rate | 0–10 L/min |
| Sample Capacity | 8–24 positions |
| Heating Power | 240 W |
| Tube Depth | 70 mm |
| Temp Accuracy | ±0.3 °C (at setpoint) |
| Operating Ambient | 0–50 °C, ≤85% RH |
| Power Supply | 220 V/50 Hz |
| Net Weight | 3.5 kg |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | NV24A-II |
| Sample Capacity | 24 positions |
| Heating Method | Dry-block heating (PTC) |
| Temperature Control | Programmable range with ±0.5 °C stability |
| Endpoint Detection | Optical fiber sensor for precise volume termination at 0.5 mL or 1.0 mL |
| Gas Flow Control | Independent per-channel on/off switching and real-time digital display of flow/pressure |
| Integrated Exhaust | Built-in active exhaust system for volatile organic compound (VOC) removal |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-2900P II |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–100 mL/min |
| Maximum Operating Pressure | 20 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Touchscreen Interface | 12-inch Capacitive Display |
| Autosampler Volume Range | 1–20 mL |
| Fraction Collection Modes | Peak-based, Full-run, Manual, Time/UV Window-triggered |
| Compatible Collection Vessels | 15 mm, 18 mm, 25 mm ID tubes and custom containers |
| Pump Configuration | Dual High-Precision Plunger Pumps |
| Gradient Mixing Accuracy | ≤0.5% RSD |
| Column Compatibility | Static HPLC prep columns (10–50 mm ID) |
| Software | Dedicated preparative chromatography control suite with user permission hierarchy and 21 CFR Part 11-compliant audit trail |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | OCTOPUS |
| Application Level | Laboratory-grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 1 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU |
| Data Acquisition Frequency | Not Specified |
| Gradient Configuration | Binary or Quaternary Pump Options |
| Compatible Detectors | PDA, ELSD, RI |
| Automation Features | Auto-sampler, Column Switcher, Intelligent Fraction Collector with Vial Rack ID Recognition and Solvent/Waste Level Sensing |
| Column Compatibility | Flash cartridges, medium-pressure glass columns, high-pressure stainless-steel columns |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | Multiple Catalog Numbers |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | Pump Series |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | QUEX-06E |
| Automation Level | Semi-Automatic |
| Channel Count | 6-Channel |
| Extraction Format | Column-Based SPE |
| Sample Capacity | 6 Samples |
| Compatible Devices | IC Columns & Syringe-Filter Assemblies |
| Material in Contact with Solvents | Chemically Resistant PTFE & Stainless Steel Components |
| Compliance | Designed for GLP-aligned sample preparation workflows |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Refractive Index Detector (RID) |
| Flow Rate Range | 1–50 mL/min |
| Flow Cell Volume | 7 µL |
| Temperature Control Range | 35–55 °C (adjustable in 1 °C increments |
| Flow Cell Pressure Rating | 6 kg/cm² |
| Internal Cell Dead Volume | 88 µL or 353 µL (selectable) |
| Linear Range | 0–2000 µRIU |
| Noise Level | ≤10 × 10⁻⁸ RIU |
| Drift (Full-Scale) | <1 mV/hour with 1 mL/min H₂O flow |
| Auto-Zero Function | Yes |
| Integrated Flush Valve | Yes |
| Digital Interface | RS-232 (bidirectional parameter transmission) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPE-10 |
| Price Range | USD 14,000 – 35,000 |
| Automation Level | Fully Automated |
| Number of Channels | Multiple Independent Channels per Module |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control | 0.1–30 mL/min |
| Solvent Selection | Up to 5 Different Elution/Wash Solvents |
| Sample Capacity per Module | 6 Samples |
| Scalability | Modular Expansion Supported |
| Sample Loading Volume | 0–5 L per Sample |
| Wetted Materials | PTFE (Polytetrafluoroethylene) |
| Pump Type | Valveless Precision Metering Pump |
| Fraction Collection | Multi-Fraction, Dual-Waste (Aqueous/Organic Separation) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | SPE-60 |
| Automation Level | Fully Automatic |
| Number of Channels | 6 parallel extraction channels |
| Extraction Format | Cartridge-based (column) SPE |
| Flow Rate Control Range | 0.1–50.0 mL/min |
| Solvent Selection Capacity | 9 independent solvent reservoirs |
| Sample Throughput | 6 samples simultaneously |
| Sample Loading Volume | 0.1–20.0 mL (expandable to 2000 mL via optional large-volume module) |
| Wetted Materials | Stainless steel (316L), PTFE |
| Column Compatibility | Interchangeable modules for 1 mL, 3 mL, 6 mL, and 12 mL SPE cartridges |
| Integrated Online Concentration | Yes |
| Robotic Positioning | XYZ-axis precision robotic arm with auto-washable sampling needle |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | SPE-CLEANER-M12 |
| Automation Level | Semi-Automatic |
| Channel Count | 12-Channel |
| Extraction Type | Column-Based SPE |
| Sample Capacity | 1–12 samples |
| Sample Loading Volume | 50 mL |
| Wetted Materials | Polytetrafluoroethylene (PTFE) and Borosilicate Glass |
| Pressure Control | Dual-Stage Adjustable Positive Pressure |
| Column Compatibility | Standard Glass SPE Columns (with Optional Adapters) |
| Application Focus | Dioxin/Furan, DL-PCBs, and PBDEs Cleanup |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPE-D6 |
| Price | USD 1,550 (approx.) |
| Automation Level | Semi-Automatic |
| Number of Channels | 6 Independent Channels |
| Extraction Format | Cartridge-Based Solid-Phase Extraction |
| Flow Control Method | Manual Valve Regulation |
| Eluent Handling | Manual Solvent Addition |
| Sample Capacity | 2 Samples Simultaneously |
| Maximum Sample Volume per Run | 4 L |
| Wetted Materials | PTFE and 316L Stainless Steel |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Automation Level | Fully Automatic |
| Channel Count | 8 Independent Channels |
| Extraction Format | Cartridge-Based SPE |
| Flow Control | Per-channel adjustable and individually shutoff pneumatic flow regulation |
| Sample Capacity | Up to 8 samples simultaneously |
| Sample Loading Volume | Standard max. 50 mL |
| Dual-Pneumatic Circuit Design | One circuit for precise liquid flow control, one dedicated to cartridge drying/dehydration |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | SPE-M08 |
| Automation Level | Semi-Automatic |
| Channel Count | 8-Channel |
| Extraction Format | Cartridge-Based SPE |
| Flow Control | Manual (Individual Valve Adjustment) |
| Solvent Delivery | Manual Loading |
| Sample Capacity | 1–8 Samples in Parallel |
| Sample Load Volume | 0–5 L |
| Wetted Materials | PTFE (Polytetrafluoroethylene) |
| Dual-Air-Path Design | One for Precise Flow Regulation, One for Post-Elution Drying |
| Compatibility | Standard SPE Cartridges & 47 mm SPE Disks |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPE-M08 |
| Automation Level | Fully Automatic |
| Number of Channels | 8 |
| Extraction Format | Cartridge-Based SPE |
| Flow Control | Independent, adjustable flow per channel with individual on/off valve control |
| Sample Capacity | Up to 8 samples simultaneously |
| Sample Loading Volume | Up to 50 mL standard |
| Dual Gas Path Design | One path for precise liquid flow regulation, one dedicated to cartridge drying/dehydration |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | SPE-M12 |
| Automation Level | Semi-Automatic |
| Channel Count | 12 Independent Channels |
| Extraction Format | Cartridge-Based SPE |
| Flow Control Method | Pneumatic Pressure Regulation |
| Solvent Types Supported | ≥5 Distinct Eluents |
| Sample Capacity | 1–12 Samples per Run |
| Sample Loading Volume | Up to 25 mL per Cartridge |
| Wetted Materials | PTFE (Polytetrafluoroethylene) |
| Valve Configuration | 12 Individually Adjustable Pneumatic Valves |
| Dual-Gas Path Architecture | One for Precise Flow Modulation, One for Post-Elution Drying/Desolvation |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPE-M48 |
| Price Range | USD 7,000–14,000 (FOB) |
| Automation Level | Semi-Automatic |
| Number of Channels | 48 |
| Extraction Format | Cartridge-Based (Column) |
| Flow Control Method | Regulated Positive Pressure (Pneumatic) |
| Solvent Selection Ports | ≥5 Independent Solvent Lines |
| Sample Capacity | 48 Samples per Run |
| Sample Loading Volume | 1–6 mL per Cartridge |
| Wetted Materials | PTFE, Stainless Steel (316), and Chemically Resistant Elastomers |
| Brand | Agela |
|---|---|
| Model | ZAM4000 |
| Detection Principle | Evaporative Light Scattering |
| Flow Rate Range | 1–50 mL/min |
| Nebulizing Gas Pressure | 3.5–5 bar |
| Nebulizing Gas Flow Rate | 1.7 L/min |
| Auxiliary Drying Gas Flow Rate | <2 m/min |
| Evaporator Temperature Range | Ambient to 85 °C |
| Light Source | Tungsten Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Output Signal | 0–5 V Analog + RS-232 Digital |
| Power-Saving Mode | Enables independent shutdown of gas, lamp, heater, and PMT |
| Fault Monitoring | Real-time diagnostics for gas flow, heater, lamp, and PMT failure |
| 雾化气流控制 | Integrated electronic pressure controller for nebulizer gas |
| Auxiliary drying gas control | Built-in controller |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-1000 |
| Instrument Type | Fast Liquid Chromatography System |
| Flow Rate Range | 0.1–100.0 mL/min (0.1 mL/min increment) |
| Maximum Operating Pressure | ≤20 MPa |
| Fraction Collection Options | F1–F4 standard tube racks (13 mm, 15 mm, 18 mm, 25 mm OD), F5 conical flask rack (up to 100 mL |
| Sample Injection Volume Range | up to 1 L |
| Temperature Control | Ambient only |
| Wavelength Range | Dual-channel UV-Vis detection at 200–400 nm and 200–800 nm (simultaneously selectable) |
| Data Acquisition Rate | Not specified |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Cleanert M96 |
| Type | 96-Well Plate-Based Solid-Phase Extraction (SPE) and Protein Precipitation Platform |
| Configuration | Benchtop, Vacuum-Driven or Positive-Pressure Assisted |
| Intended Use | High-Throughput Biological Sample Cleanup Prior to LC-MS, HPLC, or ELISA Analysis |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiracleBox |
| Pricing | Available Upon Request |
| Temperature Range | 0°C to Ambient |
| Temperature Accuracy | ±1°C |
| Thawing Time (Bovine Serum) | ≤20 min |
| Cooling-to-Setpoint Time (Bovine Serum) | ≤12 min |
| Sample Compatibility | Standard Racks, Tube Holders, 96-Well Collection Plates |
| Control Method | Dry-Programmed Heating/Cooling |
| Interface | Touchscreen with Real-Time Sample Temperature Display |
| Multi-Zone Temperature Control | Yes |
| Modular Integration Capability | Yes |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPE-40 |
| Automation Level | Fully Automatic |
| Number of Channels | 4 Parallel Channels |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control Range | 0.1–30 mL/min |
| Solvent Selection | Up to 5 Different Solvents |
| Sample Capacity | 4 Samples Simultaneously |
| Sample Loading Volume | 1–30 mL (Expandable up to 5000 mL) |
| Wetted Materials | Alumina Ceramic, PTFE, PEEK |